Features:
- Provides the fixed TM-P15 S27-01 base for a PM-D power module.
- Feeds U1 and U2 potential groups through documented 24 V DC terminals.
- Retains infeed wiring when the removable PM-D electronics are exchanged.
The base separates permanent field terminations from the plug-in power-module electronics.
Both potential inputs travel from the terminal clamps to the matched PM-D interface inside one 15 mm position.
Current, insulation and conductor limits apply to the terminal path and must be checked before station power-up.
The Siemens 3RK1903-0AA00 ET 200S TM-P15 S27-01 PM-D Terminal Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 3RK1903-0AA00 ET 200S TM-P15 S27-01 PM-D Terminal Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Bringing U1 and U2 into the PM-D position
- U1 path: The first supply conductor lands on its assigned terminal and continues to the PM-D contact.
- U2 path: The second potential follows a separate terminal path into the same module position.
- Current scope: The 10 A rating governs the terminal infeed path, not a single downstream starter channel.
- Polarity check: Both conductors are identified against the station drawing before the PM-D is inserted.
Connecting fixed wiring to removable electronics
- Terminal body: The rail-mounted base holds incoming field conductors.
- Front engagement: The PM-D plugs into the terminal-module contact interface.
- Removal state: Disconnecting the PM-D leaves U1/U2 wiring mechanically retained on the base.
- Variant match: The TM-P15 S27-01 order number must agree with the power-module configuration.
Selecting wire preparation for the terminal range
- Solid wire: Unferruled solid conductors use the documented 0.14 to 2.5 mm² range.
- Flexible wire: Ferruled flexible conductors use the narrower 0.14 to 1.5 mm² range.
- Clamp inspection: No copper should remain exposed outside the terminal after tightening.
- Load check: Terminal heating is evaluated against both conductor size and the shared infeed current.
Keeping the terminal base within its ET 200S role
- One position: The 15 mm body occupies the PM-D terminal location in the starter station.
- IP20 scope: Finger protection applies only after the station is assembled as documented.
- No output role: The base distributes supply potential; it does not generate starter commands.
- Commissioning order: Wiring is checked first, the PM-D is seated next, and the potential group is energized last.