Siemens QLSAMBAN
Siemens QLSAMBAN
Siemens QLSAMBAN
Siemens QLSAMBAN
Siemens QLSAMBAN
Siemens QLSAMBAN
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports module matching, migration review, and quotation.

QLSAMBAN

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens QLSAMBAN is the QUADLOG standard analog I/O module identified in Siemens APACS+ and QUADLOG lifecycle documentation.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for QLSAMBAN
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for QLSAMBAN

  • Manufacturer:
    Siemens
  • Part Number:
    QLSAMBAN
  • Product Family:
    Siemens Moore
  • Product Type:
    QUADLOG Standard Analog I/O Module
  • Stock:
    1
  • Signal domain:
    Analog process I/O
  • ROM version on the pictured unit:
    3.00
  • Power marking:
    24 VDC, 1.0 A max
  • I/O signal markings:
    24 VDC and 4–20 mA
  • Visible hazardous-area marking:
    Class I, Division 2, Groups A, B, C & D; verify the complete label and applicable certification before relying on it
  • Project dependency:
    Channel definition and range are configured in the installed application
  • Weight:
    4.277 lbs (1.94 kg)
  • Estimated shipping dimensions:
    4.1 x 26 x 30.7 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Control Operating Environment Compatibility & Interoperability

Features:

  • Provides the standard analog I/O role in a QUADLOG system.
  • Interfaces process signals with the configured safety/control application.
  • Appears in Siemens APACS+ and QUADLOG lifecycle documentation.
The QLSAMBAN identity must be retained exactly because the abbreviated code distinguishes this standard analog assembly from other QUADLOG modules.

Its working behavior follows the approved system configuration, termination hardware and application database.

Selection review must include channel ranges, rack assignment and the site validation package rather than relying on physical appearance.

Availability is confirmed against the complete QLSAMBAN identity, required condition, quantity and delivery destination at quotation.
Verified resources for Siemens QLSAMBAN: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Maintain analog process channels in an installed QUADLOG safety system.
  • Support staged APACS+/QUADLOG migration while existing field terminations remain in service.
  • Replace a failed standard analog I/O assembly under the site's validation procedure.
  • Analog values are delivered to the QUADLOG application for configured control or safety logic.
  • Channel scaling follows the approved project database.
  • Output action must remain consistent with the validated process response.
  • Keep the module inside the environmental limits of the installed QUADLOG cabinet.
  • Prevent conductive contamination during legacy-rack maintenance.
  • Restore ventilation and cabinet closure before the system is returned to service.
  • The board works with the QUADLOG rack, termination hardware and application generation documented for the site.
  • APACS+ components cannot be assumed interchangeable solely because they share the product-line name.
  • Migration interfaces require an engineered channel-by-channel mapping.
Description
QLSAMBAN identifies the standard analog I/O module used in the Siemens Moore QUADLOG safety and control platform. The official lifecycle listing distinguishes this assembly from other QUADLOG specialty and termination products. The standard analog designation places it in the general measurement and command layer of QUADLOG rather than among the platform's specialized communications or power assemblies.

The module carries analog process information between field-side termination hardware and the QUADLOG system logic. Channel use, range definition and safety application behavior are established by the installed project rather than by the abbreviated board name alone. In operational service, it supports continuous process variables and analog control signals whose integrity is important to the safety strategy and the associated control narrative.

Migration or spare replacement requires the complete module label, rack location, termination arrangement and application documentation. Preserve the approved channel configuration and validation records before returning a safety-related loop to operation. Any change should pass the site's management-of-change process, with loop checks and application validation confirming that scaling, alarming and final signal behavior remain unchanged.
Alternative Names
QLSAMBAN QLSAM BAN Siemens QLSAMBAN Siemens Moore QLSAMBAN QUADLOG QLSAMBAN QUADLOG Standard Analog I/O Module Siemens Moore Standard Analog I/O
Technical notes
QLSAMBAN is a QUADLOG analog I/O assembly; retain the validated channel map and safety application evidence before replacement or migration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What does the QLSAMBAN identifier represent in the Siemens QUADLOG platform?
It is the official code used for the QUADLOG standard analog I/O module.
Which project data determine how Siemens QLSAMBAN channels behave?
The approved QUADLOG application, channel range definitions and connected termination hardware establish the implemented behavior.
Why is Siemens QLSAMBAN associated with safety-system maintenance?
QUADLOG is applied in safety and critical control architectures where changes require controlled validation and documentation.
How should buyers treat the lifecycle of Siemens QLSAMBAN?
Siemens lists the APACS+ and QUADLOG line in cancellation documentation, so quotations depend on verified legacy inventory.
What must be compared before replacing a Siemens QLSAMBAN board?
Match the exact module code, rack position, field termination, channel allocation and validated application revision.
Which records help Apter quote Siemens QLSAMBAN accurately?
Provide label photographs, system cabinet details, quantity, required condition and destination plus the applicable QUADLOG manual or drawing.