Open now · we reply within 2 working hours

Talk to our team

+86 15359408275

Call and you reach an account manager, not a queue.


What happens next?

  1. Email confirmationYou will get an email confirming that we have received your enquiry.
  2. Dedicated Account ManagerOne of our team will be in touch to confirm your part(s) specification and condition.
  3. Your quoteYou will receive a comprehensive quote tailored to your specific needs.

Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 6GK5208-0BA00-2AF2

All in stock · Add one and it is quoted together with the model, one shipping cost.

6GK5208-0BA00-2AF2

Siemens 6GK5208-0BA00-2AF2 is a flat SCALANCE XF208 managed Industrial Ethernet switch with eight 10/100 Mbit/s RJ45 ports, PROFINET diagnostics, and redundant power input.

In Stock Ships by Tuesday, November 24 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 6GK5208-0BA00-2AF2

6GK5208-0BA00-2AF2Siemens SCALANCE XF208 Flat Managed Industrial Ethernet Switch
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
6GK5208-0BA00-2AF2
Product Family
Siemens SCALANCE
Product Type
SCALANCE XF208 Flat Managed Industrial Ethernet Switch
Stock
1
Weight
0.915 lbs (0.415 kg)
Estimated shipping dimensions
12.4x9x12.5cm
Tariff Code
85176200
Country of origin
Germany
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Eight 10/100 Mbit/s RJ45 ports connect controller, HMI, drive, or uplink Ethernet segments through a managed switch fabric.
  • PROFINET IO diagnostics and web, CLI, STEP 7, SNMP, and LLDP services expose configuration and port status.
  • Redundant 24 V DC feeds, a signaling contact, and optional C-PLUG storage separate power, fault, and configuration paths.
Across eight monitored copper links, Siemens 6GK5208-0BA00-2AF2 forwards industrial Ethernet frames between attached devices.

Management and PROFINET services on 6GK5208-0BA00-2AF2 make link, traffic, and fault data available without replacing physical cable checks.

The redundancy role, power feeds, signaling contact, and C-PLUG of 6GK5208-0BA00-2AF2 are configured as separate station functions.

The Siemens 6GK5208-0BA00-2AF2 SCALANCE XF208 Flat Managed Industrial Ethernet Switch may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6GK5208-0BA00-2AF2 SCALANCE XF208 Flat Managed Industrial Ethernet Switch Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Copper Links and Frame Forwarding

  • Link negotiation: Each RJ45 port establishes the supported 10 or 100 Mbit/s Ethernet link with its connected device.
  • Forwarding: The switching table sends learned unicast traffic only toward the port associated with the destination.
  • Mirroring: A configured mirror destination receives copies of selected traffic for packet analysis.
  • LLDP data: Neighbor information associates a physical port with the attached automation device during diagnosis.

Configuration and Monitoring Channels

  • Web access: The browser interface exposes switch, port, redundancy, and diagnostic settings.
  • CLI access: Command-line configuration provides a separate administrative path for supported functions.
  • STEP 7: The engineering project assigns PROFINET device and diagnostic data to the automation station.
  • SNMP: Management stations read status objects and receive configured traps through the selected SNMP version.

Ring and Parallel Network Roles

  • MRP: The configured manager or client role restores traffic around a media-redundancy ring after a link interruption.
  • HRP: High-speed ring parameters must agree across participating switches before the redundancy manager controls the path.
  • PRP: Parallel Redundancy Protocol duplicates traffic across two independent LANs for the configured end-node path.
  • Port assignment: Only ports assigned to the selected redundancy domain participate in its recovery behavior.

Supply, Signaling, and Configuration Storage

  • Redundant feeds: Two supply paths enter the four-pole terminal so one source can remain when the other is lost.
  • Fault contact: The floating signaling circuit changes state according to the configured monitored conditions.
  • Set button: Local acknowledgment or assignment follows the function enabled for the signaling contact.
  • C-PLUG: The removable medium retains supported configuration data for transfer to the exact switch type.

Description

Siemens 6GK5208-0BA00-2AF2 is a flat SCALANCE XF208 managed Industrial Ethernet switch that forwards frames between eight 10/100 Mbit/s RJ45 ports. The compact housing places the copper connections, power input, and signaling contact in a format intended for a 35 mm DIN rail.

Management services in 6GK5208-0BA00-2AF2 separate physical port operation from network configuration. Web management, CLI, STEP 7, SNMP, LLDP, and PROFINET IO diagnostics expose link state, learned neighbors, packet statistics, and error counters so the configured station can distinguish cabling faults from logical port settings.

Redundant 24 V DC feeds supply 6GK5208-0BA00-2AF2 through the four-pole terminal block, while the two-pole signaling contact reports assigned fault conditions to an external circuit. The optional C-PLUG stores the device configuration separately from the switch electronics, allowing the configuration path to remain distinct from live Ethernet traffic.

Ring and parallel-network roles in 6GK5208-0BA00-2AF2 are selected through MRP, HRP, or PRP configuration. These protocols determine which links forward normal traffic and how an alternate path is used after a topology change, while passive listening and port diagnostics provide additional visibility into the affected segment.

Mounted vertically, 6GK5208-0BA00-2AF2 operates across its full documented temperature range; horizontal installation lowers the permitted upper ambient temperature. Its IP20 enclosure, DIN-rail mounting, SSH management access, and SNTP time synchronization define the cabinet, access, and timing conditions surrounding the switching function.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Miya
ChinaQuality Inspection & Traceability

ISO 9001:2015 Quality Management Certification

Review the ISO 9001:2015 certificate for Apter Power, its certified scope, certificate number, validity, process-control purpose and the limits of management-system certification.

ISO 9001Certified quality system
TraceableDocumented order records
“ Certification matters only when the process is visible in everyday work—from the first requirement review to the final release. — Miya ”
Miya · China · August 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study
Leonia
IndonesiaBently Nevada 3500/22M 288055-01

On-Site Verification for an Indonesian Power Plant

After a previous suspected-counterfeit purchase, an Indonesian power-plant customer used a 50/50 payment plan, visited Apter Power to inspect two Bently Nevada 3500/22M 288055-01 modules, requested COO documentation and approved next-day hotel delivery.

100%Modules inspected on site
50/50Deposit / balance after inspection
“ They are very professional and supply quality products. I have purchased Bently Nevada products from them and had a very good experience. — Tri ”
Leonia · Indonesia · May 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Why does 6GK5208-0BA00-2AF2 show an RJ45 link but no traffic reaches the controller?

Check the 6GK5208-0BA00-2AF2 VLAN, port state, learned MAC table, cable pair, speed negotiation, controller address, and any configured redundancy role.

What causes 6GK5208-0BA00-2AF2 to appear in web management but remain absent from PROFINET diagnostics?

Verify the 6GK5208-0BA00-2AF2 PROFINET device name, IP assignment, engineering-project entry, station download, and DCP reachability.

Why does the signaling contact on 6GK5208-0BA00-2AF2 remain active after power is restored?

Review the 6GK5208-0BA00-2AF2 monitored fault mask, both redundant feeds, selected port states, local acknowledgment, and the two-pole contact wiring.

How should an unexpected ring interruption on 6GK5208-0BA00-2AF2 be isolated?

Compare the 6GK5208-0BA00-2AF2 MRP or HRP role, ring-port assignments, partner settings, link events, and cable path before changing switch hardware.

Why is configuration not restored from a C-PLUG in 6GK5208-0BA00-2AF2?

Confirm that the 6GK5208-0BA00-2AF2 recognizes the C-PLUG, the medium belongs to the expected device type, and no configuration or media fault is reported.

What limits 6GK5208-0BA00-2AF2 operation when it is mounted horizontally?

Horizontal mounting lowers the documented upper ambient limit for 6GK5208-0BA00-2AF2 to 40 °C; inspect orientation, enclosure temperature, and airflow.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6GK5992-1AL00-8AA0
Siemens 6GK5992-1AL00-8AA0 is an SFP992-1 optical transceiver with one LC multimode 1000 Mbit/s port for fiber links up to 750 m.
In stock
6GK5598-1AA00-3AA0
Built for SCALANCE X-500 power delivery, Siemens 6GK5598-1AA00-3AA0 converts a single-phase AC input into a regulated 24 V DC, 12.5 A output.
In stock
6GK5778-1GY00-0AA0
For industrial wireless networking, Siemens 6GK5778-1GY00-0AA0 provides one SCALANCE W778-1 M12 radio, two N-Connect antenna sockets, and two M12 Ethernet ports.
In stock
6GK5646-2GS00-2AC2
Built as an industrial security appliance, Siemens 6GK5646-2GS00-2AC2 protects connected Ethernet devices and networks with firewall, VPN and address-translation functions.
In stock
6GK5205-3BF00-2AB2
Siemens 6GK5205-3BF00-2AB2 is a SCALANCE XB205-3LD managed Layer 2 switch that links five copper devices with three long-distance single-mode fiber segments.
In stock
6GK5744-1AA60-2AA0
A wired industrial device joins a 2.4 or 5 GHz WLAN through Siemens 6GK5744-1AA60-2AA0, a SCALANCE W744-1PRO Ethernet client module.
In stock
6GK5208-0HA10-2AA6
Siemens 6GK5208-0HA10-2AA6 is a SCALANCE X208PRO managed Industrial Ethernet switch that connects eight M12 network ports in protected PROFINET installations.
In stock
6GK5761-1FC00-0AA0
Siemens 6GK5761-1FC00-0AA0 is a SCALANCE W761-1 industrial wireless access point that connects an RJ45 Ethernet segment to a 2.4 or 5 GHz IWLAN cell.
In stock
6GK5106-1BB00-2AA3
Siemens 6GK5106-1BB00-2AA3 is a SCALANCE X106-1 unmanaged Industrial Ethernet switch that connects six copper devices to one multimode fiber link.
In stock
6GK5116-0BA00-2AC2
Siemens 6GK5116-0BA00-2AC2 is a SCALANCE XC116 unmanaged Industrial Ethernet switch that connects sixteen copper network devices and reports supply or link faults.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat