Features:
- Four ports exchange IO-Link process data and device parameters with the ET 200pro station.
- Each port can be configured for IO-Link, digital input, or digital output operation.
- Port diagnostics, protected supplies, and IP65/IP67 construction support field installation.
Siemens 6ES7147-4JD00-0AB0 places four configurable IO-Link channels on one ET 200pro electronic module.
Port data on 6ES7147-4JD00-0AB0 moves between connected devices and the station backplane within the module data limits.
The bus module supplied with 6ES7147-4JD00-0AB0 anchors the electronics, while the external IO connection module completes field wiring.
Verify the complete Siemens 6ES7147-4JD00-0AB0 ET 200pro 4-Port IO-Link High Feature Electronic Module article number and interface configuration before matching the installed unit.
Siemens 6ES7147-4JD00-0AB0 ET 200pro 4-Port IO-Link High Feature Electronic Module Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
IO-Link and SIO Channel Roles
- IO-Link mode: The port exchanges cyclic process data, events, and parameter data with an IO-Link device.
- Digital input: SIO input mode reads a conventional binary field signal through the selected port.
- Digital output: SIO output mode switches the documented low-current output path.
- Mode assignment: The controller hardware configuration must match the physical device connected to each port.
Port and Module Data Limits
- Port data: An individual port can use up to 32 bytes in each process-data direction.
- Module limit: All four ports share the 32-byte input and 32-byte output totals of the module.
- Transfer rate: COM1, COM2, or COM3 is selected according to the connected IO-Link device.
- Parameter backup: The device-parameter memory stores up to 2 KB for the configured port.
Channel Fault Identification
- Wire break: Readable channel diagnostics identify an interrupted supported field connection.
- Short circuit: The affected port reports its protected-output or supply short-circuit condition.
- LED separation: Green channel status and red fault indication distinguish operation from a channel fault.
- Alarm path: The station passes the module diagnostic alarm to the configured controller.
Connection and Enclosure Boundaries
- Port A: A three-core cable carries IO-Link communication and device supply.
- Port B: Additional conductors provide the auxiliary device-power path required by the connected actuator.
- Connection module: The separate 6ES7194-4CA20-0AA0 module completes the field connector interface.
- Sealing: Specified connectors and unused-port covers retain the IP65/IP67 rating.