Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides 6DL1133-6EW00-0EH1 quotations, product manuals, and model-matching support.

6DL1133-6EW00-0EH1

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6DL1133-6EW00-0EH1 is an ET 200SP HA configurable I/O module that combines HART analog input, digital input, digital output, counting, and frequency measurement functions.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6DL1133-6EW00-0EH1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6DL1133-6EW00-0EH1

  • Manufacturer:
    Siemens
  • Part Number:
    6DL1133-6EW00-0EH1
  • Product Family:
    Siemens Simatic ET 200SP
  • Product Type:
    ET 200SP HA Configurable I/O Module
  • Stock:
    1
  • Firmware Version:
    V1.1
  • Rated Supply:
    24 V DC (19.2 to 28.8 V DC)
  • Supported Modes:
    DI, DQ, counter, and frequency measurement
  • Digital Inputs:
    16 P-reading inputs; IEC 61131 type 1 and type 3 characteristics
  • Digital Outputs:
    16 sourcing outputs; 0.5 A per channel
  • Analog Inputs:
    16 current inputs with HART support
  • Current Ranges:
    0 to 10 mA, 0 to 20 mA, and 4 to 20 mA
  • Analog Resolution:
    Up to 16 bit including sign
  • Counter Channels:
    8 channels; up to 5 kHz; 32-bit unsigned counting
  • Output Current per Module:
    2 A maximum
  • Diagnostics:
    Supply monitoring, wire-break, short-circuit, overflow, and underflow diagnostics
  • Redundancy:
    Supported with M1 terminal block
  • Operating Temperature:
    Horizontal: -40 to +70 °C; vertical: -40 to +60 °C
  • Isolation Test:
    1,500 V DC for 1 minute between channels and backplane bus
  • Weight:
    0.331 lbs (0.15 kg)
  • Estimated shipping dimensions:
    2.25x11.5x13.8cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Signal Modes HART Inputs Counting & I/O Diagnostics

Features:

  • Sixteen current channels accept HART-capable 4 to 20 mA signals alongside additional current ranges.
  • Sixteen digital inputs and sixteen sourcing outputs can be parameterized for mixed signal duties.
  • Eight input channels can perform counting or frequency measurement up to 5 kHz.
The 6DL1133-6EW00-0EH1 occupies one ET 200SP HA station position and presents its configured process values to the controller through the backplane bus.

Analog and digital modes share the same hardware, but their address areas and channel behavior change with the selected operating configuration.

Channel diagnostics and substitute-value handling let the controller distinguish wiring faults from valid process changes.

The Siemens 6DL1133-6EW00-0EH1 ET 200SP HA Configurable I/O Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6DL1133-6EW00-0EH1 ET 200SP HA Configurable I/O Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Mode Allocation

  • Analog path: Current channels convert field signals and can expose HART variables.
  • Digital path: The same module provides parameterizable digital input and sourcing output functions.
  • Mixed operation: The controller address area expands when analog, digital, and HART data are combined.
  • Online changes: Reparameterization in RUN can change supported settings without removing the module.

Current Measurement Structure

  • Input ranges: Each channel can be assigned an approved current range rather than sharing one fixed range.
  • Two-wire devices: The encoder supply can power supported two-wire current transmitters.
  • Signal conditioning: Integration time and smoothing are selected channel by channel before reporting the measured value.
  • Secondary variables: HART mode adds process variables to the module data exchanged with the controller.

Digital Channel Relationships

  • Counter pairing: Counter channels 0 to 7 use inputs 8 to 15 as hardware gates.
  • Input timing: Configurable input delay separates short disturbances from intended state changes.
  • Output loading: Each sourcing output switches its assigned load while the module total remains within the documented current limit.
  • Redundant control: Two outputs may drive one load redundantly, but they are not paralleled to increase current.

Fault Visibility and Redundancy

  • Channel faults: Wire-break, short-circuit, overflow, and underflow conditions are reported per supported channel.
  • Module indicators: PWR and DIAG LEDs distinguish supply condition from module diagnostic state.
  • Backplane isolation: Channel circuits are isolated from the backplane bus but not from one another.
  • Redundant station: An M1 terminal block provides the mechanical and electrical arrangement for module redundancy.
Description
Siemens 6DL1133-6EW00-0EH1 is a configurable SIMATIC ET 200SP HA I/O module that brings analog current measurement, HART communication, digital sensing, digital switching, counting, and frequency measurement into one station position.

The sixteen current inputs on 6DL1133-6EW00-0EH1 accept 0 to 10 mA, 0 to 20 mA, and 4 to 20 mA ranges. The 4 to 20 mA path can carry HART data, while each channel can apply its own integration and smoothing settings before values enter the controller image.

In digital operation, 6DL1133-6EW00-0EH1 uses sixteen P-reading inputs and sixteen sourcing outputs. Channels 0 through 7 can count or measure frequency, with their partner inputs supplying hardware gate signals, so acquisition and control functions share the same module without being treated as identical signal paths.

Diagnostics on 6DL1133-6EW00-0EH1 monitor supply voltage, wire break, short circuit, overflow, and underflow. The module connects its channels to the backplane through tested isolation, and an M1 terminal block permits a redundant module arrangement when the station design requires it.
Alternative Names
6DL11336EW000EH1 6DL1133 6EW00 0EH1 6DL 1133 6EW00 0EH1 Siemens 6DL1133-6EW00-0EH1 6DL1133-6EW00-0EH1 ET 200SP HA I/O Module 6DL1133-6EWO0-0EH1 6DL1133-6EW00-OEH1 6DL1133 6EW00 0EH1 HART Module
Technical notes
Siemens 6DL1133-6EW00-0EH1 combines 16 HART-capable current inputs with 16 digital input/output channels for configurable ET 200SP HA signal processing.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can 6DL1133-6EW00-0EH1 mix HART analog inputs with digital I/O in one configuration?
Yes. 6DL1133-6EW00-0EH1 supports mixed operation, and the configured mode determines the controller address area for analog, HART, digital, and quality data.
Which channels on 6DL1133-6EW00-0EH1 can count pulses?
On 6DL1133-6EW00-0EH1, channels 0 through 7 provide counting and frequency measurement, while partner inputs 8 through 15 can act as hardware gates.
Why can the process image size of 6DL1133-6EW00-0EH1 change?
The 6DL1133-6EW00-0EH1 address requirement changes with mixed, HART, multiHART, purely digital, or counter operation because each mode exchanges a different data set.
How should a two-wire transmitter be connected to 6DL1133-6EW00-0EH1?
A supported two-wire current transmitter uses the channel current input and its encoder supply on 6DL1133-6EW00-0EH1, subject to the documented quiescent-current limit.
What does a wire-break alarm mean on 6DL1133-6EW00-0EH1?
A wire-break alarm on 6DL1133-6EW00-0EH1 is a channel diagnostic; verify the selected current range, field loop continuity, and terminal assignment before changing parameters.
Does 6DL1133-6EW00-0EH1 isolate every channel from every other channel?
No. 6DL1133-6EW00-0EH1 isolates the channel circuits from the backplane bus, but the channels are not mutually isolated and are not isolated from load voltage L+.