Features:
- Sixteen thermocouple or eight RTD channels share one ET 200SP HA module.
- Two-, three-, and four-wire resistance circuits are selected channel by channel.
- H1 or M1 terminal blocks define the field connection and available redundancy topology.
Siemens 6DL1134-6JH00-0EH1 turns temperature, millivolt, and resistance signals into process-image data for an ET 200SP HA station.
Each 6DL1134-6JH00-0EH1 channel applies its assigned range, compensation, interference rejection, and smoothing before reporting a measurement.
Diagnostics and potential separation in 6DL1134-6JH00-0EH1 distinguish channel faults from supply, module, and backplane conditions.
The Siemens 6DL1134-6JH00-0EH1 ET 200SP HA Analog Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6DL1134-6JH00-0EH1 ET 200SP HA Analog Input Module Manuals,Datasheets,Link
Important Notice: Other acessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Thermocouple Signal Treatment
- Channel capacity: Sixteen thermocouple channels can be parameterized for the supported B, C, E, J, K, L, N, R, S, T, U, or TXK ranges.
- Cold junction: Compensation can use the internal junction, a fixed temperature, an external RTD, a module reference channel, or a group reference.
- Interference rejection: Each channel selects 16.6, 50, or 60 Hz rejection, which determines its integration and conversion behavior.
- Fault reporting: Wire-break, overflow, underflow, channel status, and diagnostic alarms identify measurement-path problems.
Resistance and RTD Connections
- Channel allocation: Eight RTD measurements are available because each resistance channel uses the conductors needed for its configured circuit.
- Wire modes: Two-, three-, and four-wire connections compensate lead resistance differently and must match the configured channel.
- Excitation current: The module supplies the documented measurement current through the selected resistance circuit before converting the returned voltage.
- Cable correction: For three-wire measurement, the additional compensation cycle accounts for conductor resistance in the configured path.
H1 and M1 Topology Choices
- H1 use: The H1 terminal block supports the standard single-module field connection and internal comparison-point arrangement.
- M1 use: The M1 terminal block provides the connection structure required for documented redundant-module operation.
- Color key: CC00 identifies the module-specific color coding used with its terminal arrangement.
- Wiring review: The selected terminal block, channel mode, sensor conductors, and compensation source must be consistent before commissioning.
Conversion, Smoothing, and Diagnosis
- Sigma-delta conversion: The integrating converter produces signed 16-bit values for voltage, thermocouple, and RTD ranges.
- Smoothing level: None, weak, medium, or strong smoothing is assigned per channel to balance response and noise reduction.
- Limit alarms: Two upper and two lower limit values can be assigned for channel-level process monitoring.
- Potential separation: Channels share potential with one another but remain isolated from the backplane bus and load-voltage supply.