Features:
- The starter supports electronic overload supervision.
- PROFIenergy functions support coordinated load shutdown during idle periods.
- An optional 3DI/LC module adds local-control inputs.
The current setting of 3RK1308-0BD00-0CP0 is part of the motor-protection configuration. The upper setting limit must not be treated as the default for every connected motor.
Current warning and trip thresholds perform different tasks on 3RK1308-0BD00-0CP0. A warning condition and a shutdown condition are not interchangeable events.
Phase asymmetry and blocking supervision address different motor conditions in 3RK1308-0BD00-0CP0. Their responses supplement the thermal overload model rather than replacing its configuration.
The Siemens 3RK1308-0BD00-0CP0 ET 200SP High Feature Reversing Starter may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 3RK1308-0BD00-0CP0 ET 200SP High Feature Reversing Starter Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Give local commands the defined control priority
- Accessory requirement: Local control uses the optional 3DI/LC module.
- Control selection: The LC input selects local operation and gives it priority over fieldbus commands.
- Leaving local mode: Return from local control requires the local-control selection to be inactive and the motor OFF command condition.
- Accessory removal: Removing the input module while it is controlling a running motor stops the motor.
Separate fault, trip and operating-event histories
- Fault history: The fault log records fault information in its assigned data record.
- Trip history: Trip events are recorded separately from the fault history.
- Operating events: The event log provides an additional record of operating events.
- Reading order: The circular logs place the newest entry first and identify entries by operating-hour time information.
Use PROFIenergy for the planned idle interval
- Pause command: PROFIenergy provides a command path for shutdown during planned idle periods.
- Load state: The function acts on the motor-starter load rather than changing the motor current setting.
- Measured values: Motor-current information is available through the associated measurement functions.
- Program integration: The control program uses the applicable PROFIenergy functions to coordinate the idle sequence.
Use the motor-control scenarios identified for the starter
- Conveying: Motor-driven conveyor systems are included in the application range.
- Logistics: Logistics equipment can use distributed motor-starter control.
- Production machinery: The starter application range includes production machines.
- Machine tools: Machine-tool motor control is also included in the supported application context.