Features:
- The CPU 947 executes STEP 5 programs inside the S5-155U central controller.
- Integrated parity-monitored RAM and optional 355 memory expansion organize the user program.
- Cyclic, timed, interrupt, and multiprocessor functions coordinate program execution and communication.
Siemens 6ES5947-3UA22 converts the STEP 5 program and process image into controller actions on the S5 local bus.
Memory and timing resources in 6ES5947-3UA22 support both ordinary scan execution and scheduled or event-driven blocks.
The front service interface of 6ES5947-3UA22 provides a separate path for programming, operator access, or SINEC communication.
The Siemens 6ES5947-3UA22 is the CPU 947 production version documented as functionally identical to the preceding -3UA21 version.
Siemens 6ES5947-3UA22 SIMATIC S5-155U CPU 947 Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
STEP 5 Execution Levels
- Cyclic scan: The processor repeatedly executes the configured cyclic program.
- Timed tasks: Nine time bases trigger scheduled program levels.
- Interrupt tasks: Block-boundary and hardware interrupts start configured event routines.
- Arithmetic: Floating-point operations execute inside the CPU 947 instruction set.
Program and Data Storage
- Integrated RAM: The processor provides 64 Kwords with parity monitoring.
- Expansion: A 355 memory module extends the documented capacity to 896 Kbytes.
- Retention: Program retention depends on the documented controller memory and backup arrangement.
- Clock: The integrated real-time clock supplies time information to the program.
Backplane and Service Connections
- Local bus: Two 64-pin rear connectors couple the processor to the S5 bus.
- Front port: The 15-pin connection serves programming, operator, or SINEC equipment.
- Shared resources: Multiprocessor operation coordinates common peripherals on the system bus.
- Cabinet role: IP00 construction requires installation inside the S5 controller enclosure.
Startup and Multiprocessor Behavior
- Restart selection: The documented restart type controls how retained data and program execution resume.
- Smooth STOP: Specific communication functions can continue in the defined smooth STOP mode.
- CPU pairing: A second CPU 946/947 or documented S5-135U CPU can share the controller.
- Diagnostics: Programmer status functions expose the current operating and startup condition.