Within a SIMATIC S7-400 station, Siemens 6ES7416-3FS06-0AB0 executes fail-safe and standard control programs and exchanges data through MPI/DP, PROFINET, and an optional interface module.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7416-3FS06-0AB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7416-3FS06-0AB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7416-3FS06-0AB0
  • Product Family:
    Siemens Simatic S7-400
  • Product Type:
    CPU 416F-3 PN/DP Fail-Safe Central Processing Unit
  • Stock:
    1
  • Work Memory Allocation:
    8 MB code and 8 MB data.
  • X1 Interface:
    MPI/PROFIBUS DP, up to 12 Mbit/s.
  • X5 Interface:
    Industrial Ethernet/PROFINET.
  • IF1 Expansion:
    IFM slot for IF 964-DP.
  • Engineering Software:
    STEP 7 V5.5 or later.
  • Safety Engineering:
    S7 Distributed Safety V5.4 SP1 or later.
  • Hot Restart:
    Not supported.
  • Backplane Current at 5 V DC:
    1.3 A typical; 1.5 A maximum.
  • Interface Supply at 24 V DC:
    300 mA maximum; 150 mA per DP interface.
  • Weight:
    2.379 lbs (1.079 kg)
  • Estimated shipping dimensions:
    30x23.3x6.6cm
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Safety Program Network Paths Flash Startup Applications

Features:

  • Executes fail-safe and standard control programs within one SIMATIC S7-400 CPU.
  • Divides 16 MB of work memory equally between code and data areas.
  • Provides MPI/DP, Industrial Ethernet/PROFINET, and an IFM expansion position.
The safety and standard program sections share one processing platform while remaining distinct parts of the configured control project.

X1 carries MPI or PROFIBUS DP traffic, X5 provides the Ethernet and PROFINET path, and IF1 accepts the additional PROFIBUS interface module.

A flash memory card holds the complete safety program, and the CPU does not provide a hot-restart operating mode.

The Siemens 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP Fail-Safe Central Processing Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

How fail-safe execution is organized

  • Runtime Groups: The F-program is organized into safety runtime groups that execute alongside the standard program.
  • Flash Storage: The complete safety program, including F-blocks, is stored on a flash memory card.
  • Memory Boundary: Additional F-blocks cannot be loaded later only into RAM load memory.
  • Restart Behavior: Hot restart is unavailable, so the configured safety startup sequence applies after a stop.

Distinct communication routes

  • X1 Route: The first interface operates as MPI or PROFIBUS DP at up to 12 Mbit/s.
  • X5 Route: The Ethernet interface carries PROFINET communication and online access.
  • IF1 Route: An IF 964-DP module adds a separate PROFIBUS DP connection at the expansion position.
  • Traffic Separation: The three paths let engineering, Ethernet, and additional fieldbus traffic use dedicated interfaces.

Memory and restart boundaries

  • Complete Image: The safety program is transferred as a complete image to the flash memory card.
  • F-Block Loading: Later loading of only new F-blocks into RAM load memory is not supported.
  • Cold Startup: The CPU starts through the configured startup process rather than a hot restart.
  • Consistency Check: Safety-program consistency is evaluated as part of the F-system startup and operation.

Officially defined control tasks

  • Personal Safety: The fail-safe program can execute protective functions intended for personnel safety.
  • Machine Safety: Safety logic can supervise machine-related protective functions within the configured F-system.
  • Burner Control: Burner-control safety tasks are included among the documented uses of this CPU.
  • Standard Automation: Standard control logic can run in the same CPU beside the fail-safe program.
Description
Siemens 6ES7416-3FS06-0AB0 is a CPU 416F-3 PN/DP for the SIMATIC S7-400 system. It executes the standard control program and the fail-safe program in one processor while keeping their configured program sections distinct.

For 6ES7416-3FS06-0AB0, the complete F-program resides on the flash memory card. Adding F-blocks only to RAM load memory is not supported, and the CPU does not offer hot restart.

Three communication positions give 6ES7416-3FS06-0AB0 separate routes for engineering and fieldbus access. X1 serves MPI or PROFIBUS DP, X5 carries Industrial Ethernet and PROFINET communication, and the IF1 position accepts an additional PROFIBUS interface module.

Standard automation logic and the F-program run side by side on 6ES7416-3FS06-0AB0. The standard program uses its assigned blocks, while configured safety runtime groups schedule and supervise the F-program.
Alternative Names
6ES74163FS060AB0 6ES7 416-3FS06-0AB0 6ES7 416 3FS06 0AB0 Siemens 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP 6ES7416-3FS06-0AB0 6ES7416-3FS06-OABO 6ES74I6-3FS06-0AB0 Siemens 6ES74163FS060AB0
Technical notes
Flash-based F-program storage and three separate communication positions define the operating boundary of Siemens 6ES7416-3FS06-0AB0.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why must the complete safety program be placed on flash memory for 6ES7416-3FS06-0AB0?
6ES7416-3FS06-0AB0 requires the F-program image on a flash memory card; loading additional F-blocks only into RAM load memory is not supported.
Which 6ES7416-3FS06-0AB0 interface should be assigned to PROFINET rather than PROFIBUS DP?
The X5 Industrial Ethernet interface of 6ES7416-3FS06-0AB0 carries PROFINET, while X1 and the optional IF1 path provide PROFIBUS DP functions.
Can a stopped 6ES7416-3FS06-0AB0 resume through a hot restart?
No. 6ES7416-3FS06-0AB0 does not support hot restart, so startup follows the CPU's configured restart sequence.
What software baseline is needed to engineer the safety functions of 6ES7416-3FS06-0AB0?
Engineering 6ES7416-3FS06-0AB0 requires STEP 7 V5.5 or later together with S7 Distributed Safety V5.4 SP1 or later.
How is the 16 MB work memory divided inside 6ES7416-3FS06-0AB0?
6ES7416-3FS06-0AB0 assigns 8 MB to code and 8 MB to data, preserving separate capacity for program execution and runtime data.
When is the IF1 position relevant on 6ES7416-3FS06-0AB0?
IF1 on 6ES7416-3FS06-0AB0 accepts an IF 964-DP when the project needs an additional PROFIBUS DP path beyond X1.