YOKOGAWA ATR8S-00 S2 is a pressure clamp terminal block that provides reliable RTD signal wiring for field temperature data acquisition in CENTUM VP and CENTUM CS 3000 Distributed Control Systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ATR8S-00 S2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ATR8S-00 S2

  • Manufacturer:
    Yokogawa
  • Part Number:
    ATR8S-00 S2
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Pressure Clamp Terminal Block
  • Stock:
    3
  • Signal Channels:
    8 channels
  • Rated Voltage:
    300V AC/DC
  • Rated Current:
    15A
  • Wiring Technology:
    Pressure clamping
  • Applicable Wire Gauge:
    Single strand AWG 28-12 / Multi-strand AWG 28-10
  • Housing Material:
    Polyamide 6 (PA6) high-strength insulating polymer
  • Corrosion Resistance Standard:
    Meets ISA S71.04 class G3 environmental severity level
  • Operating Temperature:
    -20°C to 70°C
  • Mounting Method:
    DIN rail mounting
  • Weight:
    0.18 kg
  • Estimated shipping dimensions:
    3.1x5.9x11.3cm
  • Tariff Code:
    2710199310
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Interoperability Installation Application Scenarios

Features:

  • Provides eight-channel RTD signal wiring with reliable pressure clamp connections for industrial temperature measurement.
  • Combines a 300 V AC/DC voltage rating, 15 A current rating, and high-strength PA6 housing for dependable industrial operation.
  • Supports DIN rail mounting and complies with ISA S71.04 Class G3 corrosion resistance requirements for demanding process environments.
YOKOGAWA ATR8S-00 S2 serves as an important field wiring component within YOKOGAWA distributed control systems by providing a dependable interface between RTD sensors and control modules. Its organized terminal layout helps simplify field installation while improving maintenance efficiency. The pressure clamp connection method also reduces installation time compared with conventional screw terminals.

The terminal block is intended for temperature measurement applications where accurate and stable RTD signal transmission is required. Eight signal channels allow multiple sensing points to be connected through a compact assembly, while broad wire gauge compatibility supports flexible panel design. Clear terminal markings further assist technicians during commissioning and servicing.

YOKOGAWA ATR8S-00 S2 is suitable for industrial facilities requiring continuous process monitoring, including power generation, petrochemical production, oil and gas processing, and manufacturing plants. The combination of DIN rail mounting, wide operating temperature capability from -20°C to 70°C, and corrosion-resistant construction supports reliable long-term operation in challenging industrial environments. Compatible integration with CENTUM VP and CENTUM CS 3000 systems makes the terminal block a practical choice for modern DCS installations.

The ATR8S-00 S2 YOKOGAWA Pressure Clamp Terminal Block may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
YOKOGAWA ATR8S-00 S2 Pressure Clamp Terminal Block Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
YOKOGAWA ATR8S-00 S2 Pressure Clamp Terminal Block Specs

General

  • Manufacturer YOKOGAWA
  • Model ATR8S-00 S2
  • Condition New Original ready stock
  • Product Family ATI3S-00 S2,ATD5A-00 S1,ATB5S-00 S2
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Signal Compatibility: Dedicated for multi-channel RTD sensor signal input, accurately matching industrial-grade three-wire or four-wire Pt100 platinum resistance thermometers.
  • System Integration: Seamlessly embedded in Yokogawa's CENTUM VP and CS 3000 systems' FIO field network, supporting high-density control cabinet hardware configuration.
  • Communication Collaboration: Through connected I/O cards, stably supports fully digital, low-latency process data upload via Vnet/IP or ESB buses.
  • Redundancy Support: Supports seamless integration with Yokogawa's dedicated dual-redundant I/O modules, ensuring backup switching for critical control loops.
  • Rail Suspension: Standard hardware design, using universal DIN rail clips for direct fixation, greatly simplifying the mechanical layout within the control cabinet.
  • Easy Wiring: Employs screwless pressure clamps. Clamp connection technology significantly reduces manual wiring time for multi-channel cabling in the field.
  • Wire Gauge Compatibility: Compatible with single-strand wire (AWG 28-12) or multi-strand wire with cold-pressed terminals (AWG 28-10), meeting diverse industrial cable standards.
  • Identification and Positioning: The box surface features clear laser-etched physical pin numbers for channels 1 to 8, preventing human error in wiring during maintenance.
  • Petrochemical Monitoring: Widely used in multi-point continuous temperature data monitoring systems for large heat exchangers and reactors in refineries and chemical plants.
  • Power Temperature Measurement: Suitable for deployment in demanding temperature acquisition applications requiring high frequency and vibration resistance, such as generator bearings and large transformer windings.
  • Pharmaceutical Production: Used in cleanroom control cabinets that meet high standards of corrosion resistance and sterility, supporting precise on-site temperature control for batch production.
  • Metallurgical Control: Performs excellently in high-temperature, high-vibration environments such as blast furnace perimeters and heat treatment workshops, ensuring stable basic automated operation in harsh process sections.
Description
YOKOGAWA ATR8S-00 S2 is a pressure clamp terminal block developed for the Field Input/Output (FIO) system of YOKOGAWA CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). It serves as the wiring interface for RTD temperature input modules, including the AAR181 module, allowing industrial temperature signals to be collected efficiently from field devices. With eight signal channels, the terminal block simplifies organized field wiring and supports dependable signal transmission.

Pressure clamp wiring technology eliminates the need for conventional screw terminals by using a secure clamping mechanism that delivers reliable electrical contact and excellent resistance to vibration. YOKOGAWA ATR8S-00 S2 supports single-strand conductors from AWG 28 to AWG 12 and multi-strand conductors from AWG 28 to AWG 10, providing flexibility for different installation requirements. Clear terminal identification also helps engineers complete wiring, inspection, and maintenance more efficiently.

YOKOGAWA ATR8S-00 S2 is rated for 300 V AC/DC and 15 A, making it suitable for demanding industrial environments. The housing is manufactured from high-strength Polyamide 6 (PA6) insulating material and complies with ISA S71.04 Class G3 corrosion resistance requirements for harsh industrial conditions. Designed for DIN rail installation, the terminal block operates reliably between -20°C and 70°C while supporting long-term performance in process automation systems.
Alternative Names
ATR8S-OO S2 ATR8S00 S2 ATK4A-00 S1 ATB5S-00 S2 ATA4S-00 S2 ATD5A-00 S1 ATI3S-00 S2 ATA4D-00 S2
Technical notes
Optimized for rapid field installation, the ATR8S-00 S2 terminal block utilizes advanced screwless pressure-clamp mechanisms to significantly reduce wiring time. It provides vibration-resistant connections accommodating a flexible wire range from AWG 28 to 10, making DIN-rail deployment exceptionally efficient.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can YOKOGAWA ATR8S-00 S2 work with AAR181 modules?
Yes. YOKOGAWA ATR8S-00 S2 is commonly used with RTD input modules such as the AAR181 to collect industrial temperature data.
Which wire sizes are compatible with YOKOGAWA ATR8S-00 S2?
The terminal block supports single-strand conductors from AWG 28 to AWG 12 and multi-strand conductors from AWG 28 to AWG 10.
Does YOKOGAWA ATR8S-00 S2 support installation in corrosive environments?
Yes. The housing meets ISA S71.04 Class G3 environmental severity requirements, providing reliable performance in demanding industrial environments.