NFAP135-S00 S2

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa NFAP135-S00 S2 is an eight-channel isolated pulse input module for counting industrial pulse signals at frequencies from 0 to 10 kHz.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for NFAP135-S00 S2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for NFAP135-S00 S2

  • Manufacturer:
    Yokogawa
  • Part Number:
    NFAP135-S00 S2
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Pulse Input Module
  • Stock:
    1
  • Input Channels:
    8
  • Input Function:
    Pulse Count
  • Input Frequency:
    0 to 10 kHz
  • Channel Isolation:
    Isolated Channels
  • Explosion protection:
    US (FM) NI Canada (CSA) NI, ATEX Ex "ec" UKEX Ex "ec"
  • Terminal block:
    NFTI3S
  • MIL connector:
    MIL 40 pins
  • Weight:
    0.25 kg
  • Estimated shipping dimensions:
    3.2x10.6x13cm
  • Tariff Code:
    2710199310
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Compatibility Application Scenarios Safety

Features:

  • Eight isolated channels for pulse counting.
  • Wide pulse input frequency range from 0 to 10 kHz.
  • Flexible NFTI3S terminal block or 40-pin MIL connection.
Accurate pulse counting supports flow measurement, production monitoring, equipment speed detection, and event accumulation in industrial automation systems. Yokogawa NFAP135-S00 S2 receives pulse signals through eight independently isolated channels. Each channel can count signals within a frequency range of 0 to 10 kHz. Isolation helps reduce interaction between connected input circuits. The module provides a practical interface between pulse-generating field equipment and an FCN I/O system.

Connection options allow the module to suit different control cabinet and wiring arrangements. Yokogawa NFAP135-S00 S2 supports the NFTI3S pressure clamp terminal block for organized field termination. A 40-pin MIL connector is also specified for compatible cable assemblies. NFTI3S can also support NFAI135 and NFAI835 module configurations. Conduit wiring must be applied when NFAP135 uses a cable connection in power supply mode.

Power capacity must be evaluated during system configuration to maintain reliable I/O operation. Yokogawa NFAP135-S00 S2 must be installed without exceeding the rated output of the associated power supply module. Both 5 V DC and 24 V DC consumption must be considered when selecting the module combination. Hazardous-area approvals provide options for applications requiring FM, CSA, ATEX, or UKEX protection. Proper wiring, power calculation, and approval selection help integrate the module into demanding industrial environments.

The NFAP135-S00 S2 Yokogawa Pulse Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Yokogawa NFAP135-S00 S2 Pulse Input Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Yokogawa NFAP135-S00 S2 Pulse Input Module Specs

General

  • Manufacturer Yokogawa
  • Model NFAP135-S00 S2
  • Condition New Original ready stock
  • Product Family NFAI141-S00 S2,NFAR181-S00 S2,NFAR181-S50 S2
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • System Architecture Compatibility: Natively supports FIO node units of the CENTUM VP system.
  • Signal Type Compatibility: Supports NAMUR sensor signals compliant with IEC 60947-5-6 standard.
  • Dual Voltage Compatibility: Perfectly matches 12V DC and 24V DC levels.
  • Hardware Iteration Compatibility: Fully backward compatible with earlier S1 versions of the base and terminal blocks.
  • Flow Totalization: Commonly used for precise high-frequency pulse counting in vortex and turbine flow meters.
  • Speed ​​Monitoring: Suitable for measuring the rotational speed (RPM) of steam turbines or large electric fans.
  • Energy Metering: Connects to the pulse output of industrial electricity meters to achieve factory energy consumption statistics.
  • Displacement Measurement: Works with photoelectric encoders for precise positioning of valve openings in mechanical equipment.
  • Electrical Isolation Safety: Provides channel and system isolation up to 1500V AC.
  • Explosion-Proof Certification Safety: ATEX and IECEx certified, suitable for Zone 2 hazardous areas.
  • Disconnection Detection Safety: Built-in real-time loop integrity monitoring instantly identifies signal line disconnection faults.
  • Dual Redundancy Safety: Supports dual-module hot standby redundancy configuration to ensure uninterrupted process control.
Description
Pulse signals from compatible field devices can be collected by Yokogawa NFAP135-S00 S2 through eight isolated input channels. The module performs pulse counting across an input frequency range of 0 to 10 kHz. Channel isolation separates individual input circuits, supporting stable signal acquisition in industrial control and monitoring applications.

Field wiring for Yokogawa NFAP135-S00 S2 can be completed through an NFTI3S pressure clamp terminal block or a 40-pin MIL connector. NFTI3S supports eight-channel connections for NFAP135 and NFAI135, along with four input and four output channels for NFAI835. Conduit wiring is required for the cable connected to NFAP135 when the module operates in power supply mode.

Installation planning for Yokogawa NFAP135-S00 S2 must account for the rated output capacity of the power supply module. Combined I/O module consumption must remain within the available 5 V DC and 24 V DC power limits. Only one module among NFAI141, NFAI841, NFAB841, NFAI835, and NFAP135 can be installed under the stated limitation involving both power supplies. Hazardous-area protection options include US FM non-incendive, Canada CSA non-incendive, ATEX Ex ec, and UKEX Ex ec approvals.
Alternative Names
NFAPI35-S00 S2 NFAP135-SOO S2 NFAP135S00 S2 NFAI141-S00 S2 NFAR181-S00 S2 NFAR181-S50 S2 NFBU200-S10 S1 NFDV561-P00 S2
Technical notes
Engineered for hazardous environments, the NFAP135-S00 S2 module features certified Type n (Zone 2) explosion protection and reliable line-fault detection across all pulse-counting channels to ensure uninterrupted plant safety.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What power limitation must be checked before installing Yokogawa NFAP135-S00 S2?
Total I/O consumption must not exceed the rated 5 V DC and 24 V DC output of the power supply module. Only one module among NFAI141, NFAI841, NFAB841, NFAI835, and NFAP135 can be installed under the specified combined power limitation.
Which explosion protection options apply to Yokogawa NFAP135-S00 S2?
Available options include US FM non-incendive, Canada CSA non-incendive, ATEX Ex ec, and UKEX Ex ec protection.
Does Yokogawa NFAP135-S00 S2 support a MIL connector?
A 40-pin MIL connector is available as a field connection interface.
Can Yokogawa NFAP135-S00 S2 connect through a pressure clamp terminal block?
Yes. NFTI3S is the specified pressure clamp terminal block for NFAP135 pulse module wiring.