    Apter Power supports quotations, ASI533 checks, documents, and single-output terminal matching for ATSS3S.

ATSS3S

/ 4.9
1001 reviews | Need a Specific Revision?
Yokogawa ATSS3S is a single 8-point analog output pressure clamp terminal block for the ASI533 built-in-barrier module for the CENTUM VP Built-In Barrier I/O Terminal Blocks family.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for ATSS3S
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for ATSS3S

  • Manufacturer:
    Yokogawa
  • Part Number:
    ATSS3S
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Pressure Clamp Terminal Block for Analog Output
  • Stock:
    1
  • Signal Service:
    Analog output
  • Channel Capacity:
    8 points
  • I/O Arrangement:
    Single
  • Compatible Module:
    ASI533
  • Terminal Style:
    Pressure clamp
  • Suffix Code:
    -0
  • Surge Absorber:
    Not included
  • Corrosive-Gas Compliance:
    ISA S71.04 Class G3
  • Temperature Range:
    -20 to +70 C
  • Weight:
    0.2 kg
  • Estimated shipping dimensions:
    Product dimensions: 6.05 x 3.26 x 11.4 cm (W x D x H).
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications ASI533 Matching Output Wiring Single Layout

Features:

  • ASI533 output matching: The terminal block is specified for the built-in-barrier analog output module.
  • Single 8-point format: Pressure-clamp termination serves the documented output points.
  • Class G3 scope: The official specification states ISA S71.04 Class G3 compliance.

ATSS3S provides single analog-output field termination for the Yokogawa ASI533 module with built-in barrier.

The official suffix -0 configuration does not include a surge absorber and should not be inferred from similar input models.

Before purchase, verify ASI533, output-loop wiring, the single arrangement, suffix, and cabinet environmental requirements.

Availability is subject to Apter Power's current inventory and sourcing confirmation.

Yokogawa ATSS3S Pressure Clamp Terminal Block for Analog Output Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Yokogawa ATSS3S Pressure Clamp Terminal Block for Analog Output Specs

General

  • ManufacturerYokogawa
  • ModelATSS3S
  • ConditionNew Original ready stock
  • Product FamilyCENTUM VP Built-In Barrier I/O Terminal Blocks

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Built-in-barrier output review

  • Module identity: Confirm ASI533 on the installed output module.
  • Output points: Retain the documented eight-channel assignment.
  • Single arrangement: Do not infer redundant output operation.
  • Suffix: Verify ATSS3S-0 from the complete installed identity.

Analog output termination

  • Signal direction: Keep ATSS3S within analog output service.
  • Terminal method: Use the pressure-clamp wiring schedule.
  • Surge scope: No integrated surge absorber is listed.
  • Loop test: Verify each output path after replacement.

Cabinet installation checks

  • Clearance: Use the official external dimensions for installed-space review.
  • Temperature: Confirm the -20 to +70 C specification.
  • Class G3: Retain the documented corrosive-gas requirement.
  • Sourcing: Include the ASI533 identity and terminal drawing.
Description
The Yokogawa ATSS3S is a single 8-point analog output pressure clamp terminal block for the ASI533 built-in-barrier module in the CENTUM VP Built-In Barrier I/O Terminal Blocks family.

Official Yokogawa documentation lists ATSS3S for this configuration. It provides field termination for ASI533 in the documented single arrangement without a surge absorber.

Before ordering ATSS3S, verify ASI533, the single output arrangement, suffix -0, loop wiring, and cabinet environment.
Alternative Names
Yokogawa ATSS3S ATSS3S ATSS 3S ATSS-3S YOK ATSS3S ATSS3S Pressure Clamp Terminal Block for Analog Output ATSS3S CENTUM VP ATSS3S FIO hardware
Technical notes
Yokogawa ATSS3S is a single 8-point analog output pressure clamp terminal block for the ASI533 built-in-barrier module. Verify the complete ordering code, connected hardware, and field interface before procurement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What should an ATSS3S purchase request include?
Provide ASI533, suffix -0, eight output points, terminal drawing, quantity, condition, destination, and required delivery date.
Can ATSS3S be used for ASI133 analog input?
No. ATSS3S is documented for ASI533 analog output; ASI133 input uses a different terminal block.
Does ATSS3S include a surge absorber?
No. Yokogawa lists the ATSS3S-0 configuration without a surge absorber.
Can ATSS3S replace the dual-redundant ATSS3D?
Do not assume that it can. ATSS3S is single and the cabinet architecture must match.
What should be checked before transferring output wiring to ATSS3S?
Review loop polarity, terminal numbering, ASI533 identity, output schedule, suffix, and commissioning procedure.
Why should ATSS3S not be selected only from its eight-point count?
Channel count does not establish signal direction, compatible module, single architecture, suffix, or barrier application.
Where can procurement request the ATSS3S datasheet and quote?
Use the PDF in Manuals and send Apter Power the ASI533 and output-loop details.