Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>

BTV06.1HN-RS-FW

/ 4.9
1001 reviews | Need a Specific Revision?
INDRAMAT BTV06.1HN-RS-FW is a compact BTV 06 machine operator panel with graphic display, programmable keys, serial interfaces and 24 VDC I/O.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for BTV06.1HN-RS-FW
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for BTV06.1HN-RS-FW

  • Manufacturer:
    indramat
  • Part Number:
    BTV06.1HN-RS-FW
  • Product Family:
    indramat
  • Product Type:
    BTV 06 miniature operator panel
  • Stock:
    1
  • Display:
    240 × 128 pixel graphic LCD
  • Keyboard:
    39 keys including seven programmable keys
  • Processor:
    68000-family CPU
  • Program memory:
    1 MB flash
  • Working memory:
    512 KB RAM
  • Communication:
    Two serial interfaces
  • Local I/O:
    Ten 24 VDC I/O points
  • Firmware:
    Ordered separately for the application
  • Dimensions:
    31.8 × 20 × 5.3 cm
  • Weight:
    1.7 kg
  • Tariff Code:
    8537109090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Operator Hardware Application Memory Return to Service Application
  • Compact BTV 06 machine operator station
  • Graphic LCD and programmable keypad
  • Dual serial interfaces with local 24 VDC I/O

BTV06.1HN-RS-FW is a compact local interface for legacy Indramat-controlled machinery.

It presents the machine application through a graphic LCD and keyboard while exchanging data over serial links and local discrete I/O.

The separately ordered firmware and operator project are essential parts of the installed configuration.

Availability, condition, price, and shipping time for BTV06.1HN-RS-FW are confirmed during quotation.

INDRAMAT BTV06.1HN-RS-FW Product Family and Support Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • 240 × 128 graphic LCD
  • Membrane keypad with programmable keys
  • Compact panel-mount construction
  • Flash stores firmware and application
  • RAM supports operating data
  • Firmware package must be identified separately
  • Restore the approved project
  • Confirm serial links and local I/O
  • Test all keys, displays and machine commands
  • Legacy Indramat machine operator stations
  • Local drive and automation control
  • Panel-mounted status, command and recipe interfaces
Description
BTV06.1HN-RS-FW provides local machine operation through a 240 × 128 graphic display, membrane keyboard and programmable function keys.

The panel uses a 68000-family processor with flash and RAM, two serial interfaces and ten 24 VDC I/O points for operator-station integration.

Firmware is ordered separately for the BTV 06 family, so the replacement record must include the complete panel code, firmware package, project data, serial configuration and connector pinout.
Alternative Names
BTV06.1HN-RS-FW BTV 06.1HN-RS-FW BTV061HNRSFW BTV 06 Miniature Control Panel Indramat BTV06 Operator Panel
Technical notes
INDRAMAT BTV06.1HN-RS-FW is a BTV 06 compact operator panel with 240 × 128 graphics, membrane keys, flash and RAM, two serial ports, 24 VDC I/O and separate firmware.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Is firmware included with INDRAMAT BTV06.1HN-RS-FW?
The BTV 06 documentation treats firmware as a separate order item, so confirm whether the quoted INDRAMAT BTV06.1HN-RS-FW includes the required package and application.
What data should be saved before replacing INDRAMAT BTV06.1HN-RS-FW?
Back up the operator project, firmware identifier, parameters, recipes and any retained data used by INDRAMAT BTV06.1HN-RS-FW.
Can another BTV 06 panel with the same front size replace INDRAMAT BTV06.1HN-RS-FW?
Only after matching the complete type code, interface execution, firmware and project compatibility; appearance alone is not sufficient for INDRAMAT BTV06.1HN-RS-FW.
What should be checked if the display of INDRAMAT BTV06.1HN-RS-FW is blank?
Verify supply, fuse or protection circuit, contrast or backlight condition, connector seating and boot behavior before replacing INDRAMAT BTV06.1HN-RS-FW.
Why might the machine stop communicating after fitting INDRAMAT BTV06.1HN-RS-FW?
Serial format, cable pinout, port assignment and firmware application must match the controller connected to INDRAMAT BTV06.1HN-RS-FW.
Does INDRAMAT BTV06.1HN-RS-FW provide local machine I/O?
For INDRAMAT BTV06.1HN-RS-FW, the BTV 06 family documents ten 24 VDC I/O points; confirm how the machine project assigns those points before transferring wiring.
How should INDRAMAT BTV06.1HN-RS-FW be accepted after installation?
For INDRAMAT BTV06.1HN-RS-FW, verify boot, display, every key, serial communications, local I/O, alarms, recipes and all operator functions used by the machine.