Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports base-label review, DSQC253 condition checks, S3 documentation, and responsive legacy-part sourcing.

3HAA3563-AMA

/ 4.9
1001 reviews | Need a Specific Revision?
ABB 3HAA3563-AMA is the base article for the DSQC253 serial measurement board used in the S3 robot measurement system.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 3HAA3563-AMA
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3HAA3563-AMA

  • Manufacturer:
    ABB
  • Part Number:
    3HAA3563-AMA
  • Product Family:
    ABB Robots
  • Product Type:
    DSQC253 Serial Measurement Board
  • Stock:
    1
  • ABB board designation:
    DSQC253
  • Control-system context:
    S3
  • Documented location:
    Mechanical unit
  • Measurement architecture:
    Serial measurement loop
  • Published fault branches:
    Wiring or internal board fault
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Sweden
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals S3 Board Role Loop Fault Isolation Base Model Control Product Applications

Features:

  • DSQC253 identity: historical ABB material names the serial measurement board
  • S3 mechanical-unit location: the board operates in the robot measurement loop
  • Two-branch diagnosis: ABB separates wiring faults from internal board faults
3HAA3563-AMA is the base article used here for the DSQC253 serial measurement board family.

The board sits in the mechanical unit and participates in the S3 measurement loop.

Diagnosis must distinguish loop wiring from an internal board failure before hardware is exchanged.
Apter Power can review the 3HAA3563-AMA base marking, DSQC253 identity, S3 application evidence, and condition requirements.
ABB 3HAA3563-AMA DSQC253 Serial Measurement Board Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Board designation: ABB service documentation identifies DSQC253.
  • System context: the board belongs to the S3 measurement system.
  • Hardware level: it is a serial measurement board rather than a main computer.
  • Reported symptom: the control system can indicate no data from the measurement loop.
  • First branch: wiring in the loop is a documented possible cause.
  • Second branch: an internal DSQC253 fault is the alternate documented cause.
  • Article identity: the product is represented by the base 3HAA3563-AMA code.
  • Variant boundary: the base code does not prove all slash suffixes equivalent.
  • Release evidence: retain the complete marking from the installed board.
  • S3 serial measurement service: maintain the robot measurement loop at the mechanical-unit level.
  • DSQC253 fault isolation: distinguish wiring loss from an internal measurement-board fault.
  • Legacy board sourcing: match the base article to the installed board record before replacement.
Description
Within ABB S3 mechanical-unit electronics, 3HAA3563-AMA is the DSQC253 serial measurement board used in the robot position-measurement loop.

Keeping the base 3HAA3563-AMA article tied to its S3 board location and loop wiring helps technicians narrow service to the measurement path without assuming that /0, /1 or /2 suffix variants are equivalent.
Alternative Names
3HAA3563AMA ABB DSQC253 DSQC 253 serial measurement board ABB S3 measurement board
Technical notes
Historical ABB documentation places the DSQC253 in the mechanical unit and diagnoses missing loop data from either wiring or an internal board fault. For 3HAA3563-AMA, that two-branch diagnosis is the key boundary: isolate the measurement-loop wiring before condemning the board, and stop if the installed suffix is unreadable.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Where does 3HAA3563-AMA operate in an ABB S3 measurement system?
It serves as the DSQC253 serial measurement board in the mechanical unit. Use that location to distinguish it from controller-cabinet computer boards before ordering.
What should be checked first when 3HAA3563-AMA is suspected after loop data disappears?
Start with the measurement-loop wiring. ABB’s DSQC253 fault table lists wiring and internal board failure as separate causes, so replace the board only after the wiring branch is excluded.
Can a slash-suffix board be assumed equivalent to the base 3HAA3563-AMA?
No. The base article identifies the DSQC253 family but does not establish universal interchangeability among historical suffixes. Stop the match when the installed full marking is unavailable.
How does the DSQC253 identity help confirm an offer for 3HAA3563-AMA?
It gives the expected serial-measurement object and S3 context. Reject an offer described only as a servo controller or generic automation board without DSQC253 evidence.
What evidence should remain available before removing 3HAA3563-AMA from the mechanical unit?
Keep the loop fault indication and the complete installed board label before disconnection. Those two records preserve both the diagnostic branch and the suffix-selection boundary.
Which information should an RFQ for 3HAA3563-AMA include to avoid a generic board quote?
State the DSQC253 designation, S3 mechanical-unit context, and the full installed marking if visible. Pause the quote if the requested base model cannot be tied to the removed board.