- Published power dissipation is 34, 45, 57, 70, and 84 W at 20, 40, 60, 80, and 100% rated output
- Control-module power dissipation is included in the published IAM/AM inverter figures
- Internal-shunt power is excluded and must be added according to utilization
2094-AM02-S has a model-specific loss profile for enclosure heat calculations at different output levels.
Use the expected axis duty point when selecting the applicable loss value and add any internal-shunt contribution separately.
Install the module upright and size enclosure cooling from the combined losses of the complete installed system and its usable heat-transfer area.
Availability, condition, price, and shipping time for 2094-AM02-S are confirmed during quotation.
Allen-Bradley 2094-AM02-S Kinetix 6000 Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Install the axis module to the right of the Integrated Axis Module on the Bulletin 2094 rail
- Order axis modules from highest to lowest power utilization
- Mount the shunt after the last axis module and place slot fillers after the shunt
- The motor-power connector accepts 6...1.5 mm² conductors (AWG 10...16)
- The published strip length for the motor-power conductors is 10 mm
- The specified motor-power terminal torque is 0.5...0.6 N·m
- The selected motor winding and feedback type must appear in the current Rockwell Automation compatibility data
- Connector kits and 2090-series cables must match the exact motor-feedback interface
- Hardware series and firmware must be checked before replacing an installed module
- Additional higher-current axes in 200/230 V-class Kinetix 6000 multi-axis machines
- Shared power-rail systems with a compatible IAM sized for the complete axis load
- Servo applications requiring the documented Safe Torque Off interface