Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power coordinates quotation, official records, project matching, and procurement support.

2713P-T10CD1

/ 4.9
1001 reviews | Need a Specific Revision?
The 2713P-T10CD1 is a 10.4-inch PanelView 5310 SVGA touch terminal with one Ethernet controller port and Studio 5000 View Designer integration.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2713P-T10CD1
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2713P-T10CD1

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2713P-T10CD1
  • Product Family:
    PanelView
  • Product Type:
    PanelView 5310 Graphic Terminal
  • Stock:
    1
  • Display Size:
    10.4 in.
  • Display Resolution:
    800 × 600 SVGA
  • Aspect Ratio:
    4:3
  • Operator Input:
    Analog resistive touch
  • View Area:
    211 × 158 mm
  • Color Depth:
    24-bit, 16.7 million colors
  • Memory:
    1 GB RAM
  • Project Storage:
    1 GB nonvolatile
  • Ethernet:
    One 10/100Base-T port
  • USB:
    One high-speed host port
  • External Storage:
    One SD card slot
  • Input Voltage:
    18...30 V DC
  • Power Consumption:
    15 W max; 12 W typical
  • Status Indicators:
    STS and ERR
  • Enclosure Rating:
    NEMA/UL Type 4X, 12, 13; IP66
  • Weight:
    0.79 kg
  • Estimated shipping dimensions:
    25.2 × 29.7 × 6.95 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Logix Integration Status Diagnostics Storage Workflow Product Applications

Features:

  • Machine-level display: 10.4-inch 4:3 SVGA resistive-touch interface
  • Endpoint Ethernet: one 10/100Base-T port for controller communication
  • Service visibility: STS and ERR indicators support structured diagnostics
The exact order code selects the branded, non-conformal-coated version without the -B or -K suffix.

Its single-port architecture differs fundamentally from embedded-switch terminals even when the screen size appears similar.

Recovery planning should cover the application, firmware, controller reference, and removable media before a failed unit is exchanged.

Apter Power supports 2713P-T10CD1 enquiries with official-document checks, network-scope review, quotation, and purchasing coordination.

Verified resources for 2713P-T10CD1:

Important Notice: Confirm the required application files, firmware, cables, accessories, and documentation in the quotation before ordering.
  • Engineering portal: use the Studio 5000 environment for View Designer and Logix Designer work.
  • Controller path: retain the approved controller reference and IP plan.
  • Endpoint rule: connect one Ethernet cable to the terminal; do not use it for ring transit.
  • Release test: prove reads, writes, alarms, and security against the production controller.
  • STS indication: use the green status light with the terminal diagnostic view.
  • ERR indication: correlate the red error light with project, firmware, and communication evidence.
  • Isolation step: establish stable 24 V DC before changing software or network settings.
  • Recordkeeping: capture indicator behavior and event details before power cycling.
  • SD slot: use supported media for approved external-storage tasks.
  • USB host: connect removable storage only through the documented procedure.
  • Power discipline: never remove media during a write, restore, or firmware operation.
  • Recovery proof: validate the restored project offline before returning control.
  • Machine operator stations: monitor and control supported Logix equipment through a local SVGA display.
  • Compact process panels: present alarms, status, and commands on a 10.4-inch 4:3 workspace.
  • Single-port HMI nodes: connect a View Designer terminal as an endpoint in an approved Ethernet architecture.
Description
Built for machine-level Logix visualization, 2713P-T10CD1 is a 10.4-inch PanelView 5310 touch terminal with an 800 × 600 display and a single 10/100Base-T controller connection.

Status and error indicators help 2713P-T10CD1 separate terminal health from application or network conditions, while the SD slot and USB host port support documented external-storage workflows.

Commissioning 2713P-T10CD1 requires the approved View Designer project, matching firmware, controller reference, 24 V DC supply, panel opening, and validated recovery media rather than display-size matching alone.
Alternative Names
Allen-Bradley 2713P T10CD1 AB 2713PT10CD1 PanelView 5310 10.4-inch touch terminal 2713P T10CD1 SVGA HMI Rockwell View Designer single-port terminal
Technical notes
A single Ethernet port makes 2713P-T10CD1 an endpoint, not a DLR transit device. Trace the existing cable path before replacement; if the removed HMI carries two active network cables or closes a ring, stop the swap and redesign the connection with approved switching hardware or a suitable terminal configuration.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why cannot 2713P-T10CD1 preserve a daisy-chain connection from a dual-port HMI?
It has one Ethernet port and no embedded switch. Route the endpoint through an approved external switch or select suitable hardware before removing a transit device.
How should the ERR light on 2713P-T10CD1 be investigated?
Establish stable power, read terminal diagnostics, review firmware and project status, then test the controller path. Avoid replacing hardware until the error source is isolated.
What must match before restoring an SD backup to 2713P-T10CD1?
Match the full catalog identity, firmware, View Designer project revision, controller reference, and approved media contents, then complete an offline functional check.
How should a technician decide whether the existing panel opening can accept 2713P-T10CD1?
Use the official 224 × 269 mm opening and confirm the enclosure surface, mounting hardware, service depth, and environmental rating before fabrication or replacement.
How does 2713P-T10CD1 support a structured outage diagnosis?
Its separate STS and ERR indicators, terminal diagnostics, and single network path allow technicians to distinguish power, terminal, project, and controller-communication conditions methodically.
What should a buyer include when requesting a quote for 2713P-T10CD1?
Send the full label, suffix status, firmware, View Designer backup, controller family, panel opening, quantity, destination, and required delivery date.