Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power can assist IC660BBR101 buyers with pricing enquiries, sourcing coordination, and relevant official General Electric documentation.

IC660BBR101

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC660BBR101 is a sixteen-output normally-open Genius relay block divided into four isolated groups for AC and DC field loads.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC660BBR101
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC660BBR101

  • Manufacturer:
    General Electric
  • Part Number:
    IC660BBR101
  • Product Family:
    GE Genius I/O
  • Product Type:
    115/230 VAC 16-Circuit Normally-Open Relay Block
  • Stock:
    1
  • Relay Outputs:
    16 normally-open
  • Output Groups:
    4 isolated groups of 4
  • Block Power:
    93 to 132 VAC or 185 to 265 VAC
  • Load Voltage:
    5 to 250 VAC or 5 to 220 VDC
  • Output Current:
    2 A per circuit
  • Minimum Load:
    10 mA recommended
  • Switching Frequency:
    20 cycles/minute for inductive loads
  • Weight:
    4 lbs (1.8 kg)
  • Estimated shipping dimensions:
    8.83 x 3.50 x 3.94 in (22.44 x 8.89 x 10.00 cm)
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Output Contacts AC/DC Loads Commissioning

Features:

  • Normally-open relay action is provided on all sixteen output circuits
  • Four isolated groups permit separate compatible load supplies
  • Contact ratings cover both AC and DC switching applications
The IC660BBR101 catalog number selects normally-open contacts; it is electrically distinct in safe-state behavior from the BBR100 normally-closed block.

Four isolated relay banks give the control design flexibility to switch different AC or DC load sources from one Genius network device.

Contact life depends on current, voltage, inrush, power factor, switching rate, and suppression, so these values should be reviewed against the field load before installation.

The General Electric IC660BBR101 115/230 VAC 16-Circuit Normally-Open Relay Block is available for quotation, official documentation, configuration review, and system-matching support from Apter Power.
General Electric IC660BBR101 115/230 VAC 16-Circuit Normally-Open Relay Block Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC660BBR101 115/230 VAC 16-Circuit Normally-Open Relay Block Specs

General

  • ManufacturerGeneral Electric
  • ModelIC660BBR101
  • ConditionNew Original ready stock
  • Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Normally-open arrangement

  • De-energized state: Every output contact is open when its relay is not energized.
  • Group count: Sixteen contacts are divided into four banks of four.
  • Source flexibility: Isolated groups may switch different compatible supplies.
  • Logic indication: Circuit LEDs represent the relay coil state.

Field-load limits

  • AC duty: Use loads within 5 to 250 VAC and the rated apparent power.
  • DC duty: Use loads within 5 to 220 VDC and the rated wattage.
  • Current rating: Limit each circuit to the specified 2 A maximum.
  • Small loads: Maintain the recommended 10 mA minimum for dependable contact action.

Contact-life review

  • Inrush: Measure startup current rather than relying only on steady-state current.
  • Cycle rate: Keep inductive operation within 20 cycles per minute.
  • Suppression: Fit appropriate components for coils or other stored-energy loads.
  • Safe state: Test the process response with outputs commanded off and power removed.
Description
All sixteen outputs on IC660BBR101 use normally-open relay contacts and are arranged as four isolated groups. This architecture supports field devices that must remain de-energized until the corresponding relay command is active.

IC660BBR101 can switch loads from 5 to 250 VAC or 5 to 220 VDC, up to 2 A on each circuit. The manual specifies a 10 mA recommended minimum load and limits inductive switching to 20 cycles per minute.

The relay block draws its electronics power from a 115 VAC or 230 VAC source while the four contact groups may switch separate field sources. Installation of IC660BBR101 should confirm the normally-open requirement, group commons, load suppression, contact duty, Genius address, and output default strategy.
Alternative Names
IC 660 BBR101 IC-660-BBR101 GE IC660BBR101 GE Fanuc IC660BBR101 General Electric IC660BBR101 IC660 BBR 101 GE Genius IC660BBR101 IC660BBR101 115/230 VAC 16-Circuit Normally-Open Relay Block
Technical notes
IC660BBR101 provides sixteen normally-open relay outputs, divided into four isolated banks for separately supplied AC or DC loads.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which contact state is standard on IC660BBR101?
IC660BBR101 uses normally-open contacts on all sixteen outputs.
How many isolated groups does IC660BBR101provide
IC660BBR101 contains four output groups, each with four relays.
What is the recommended minimum load for IC660BBR101?
IC660BBR101 has a documented 10 mA recommended minimum load.
Which field-load range applies to IC660BBR101?
IC660BBR101 can switch 5 to 250 VAC or 5 to 220 VDC.
How often may inductive loads be switched by IC660BBR101?
IC660BBR101 is limited to 20 cycles per minute for inductive load duty.
What wiring check distinguishes IC660BBR101?
IC660BBR101 must be verified for normally-open safe-state behavior and separate group sources.
Who can provide documentation and quotation support for IC660BBR101?
IC660BBR101 can be sourced and reviewed through Apter Power with official documentation and quotation support.