Features:
- Converts dynamic machinery shock forces into proportional differential voltage output signals.
- Utilizes a shear ceramic element encased in a hermetically sealed 304L stainless steel casing.
- Includes a 3/8-24 to 1/4 NPT mounting adapter stud and 5-pin top connection receptacle.
Order designation 200150-06-05 specifies the general-purpose Trendmaster piezoelectric accelerometer equipped with a 1/4 NPT threaded mounting adapter and multiple hazardous location agency approvals.
Engineered for continuous plant-wide machinery health monitoring, this seismic transducer streams raw vibration acceleration data into Trendmaster scanning infrastructure to track asset degradation.
Field mounting requires torquing the 3/4-inch hex base between 2.7 and 6.8 N·m onto a flat, smooth, surface-prepared machine casing to guarantee optimal high-frequency acoustic transmission.
Availability: Standard Dispatch - Verified In Stock
Bently Nevada 200150-06-05 Trendmaster Accelerometer Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Serves as a permanent sensing node within Trendmaster ProTIM continuous machinery health networks.
- Captures early mechanical dynamic signature changes caused by bearing element wear and structural looseness.
- Provides continuous housing vibration data inputs to prevent catastrophic unbalance in rotating machinery skids.
- Features a hermetically sealed 304L stainless steel casing engineered for harsh industrial washdown environments.
- Provides continuous ingress protection against moisture penetration, fine particulate dust, and process chemical vapors.
- Withstands mechanical base shock up to 4,905 m/s² peak without causing sensor housing degradation.
- Holds multiple hazardous location certifications, including CSA, ATEX, and IECEx intrinsically safe ratings.
- Satisfies European CE directives for high-level immunity against industrial electromagnetic interference.
- Meets American Petroleum Institute (API) 670 machinery protection system standards for housing-mounted sensors.
- Operates as a pure analog piezoelectric sensor without requiring embedded internal firmware updates.
- Maintains fixed factory-calibrated sensitivity without digital field flash re-programming dependencies.
- Integrates seamlessly into updated Bently Nevada System 1 diagnostic software scanning schedules.