Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides IS200ACLEH1A quotations, English control data and EX2100 system-matching support.

IS200ACLEH1A

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IS200ACLEH1A is an EX2100 Application Control Layer carrier board that connects the ACLE processor assembly to faceplate communications and the control-rack backplane.
In Stock
Ships by Tuesday, September 29
Fast Shipping Available
Get a quick price for IS200ACLEH1A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IS200ACLEH1A

  • Manufacturer:
    General Electric
  • Part Number:
    IS200ACLEH1A
  • Product Family:
    GE Excitation Control
  • Product Type:
    Application Control Layer Carrier Board
  • Stock:
    1
  • Functional Acronym:
    ACLE
  • Control Platform:
    EX2100 Excitation Control
  • Carrier Configuration:
    No adjustable jumpers
  • Ethernet Connectors:
    ENET1 and ENET2, RJ-45
  • Serial Connectors:
    COM1 and COM2, DB9
  • Compact Flash Position:
    P9
  • Backplane Interface:
    P1
  • Ribbon Interfaces:
    P3, P4, P5, P6 and P13
  • Faceplate Indicators:
    OK, ACTIVE, ENET, FLASH and STATUS
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Connectivity Software Setup Status Signals Carrier Layout

Features:

  • Carries the processor, compact-flash and communication interfaces of the ACLE assembly.
  • Provides two RJ-45 Ethernet ports and two DB9 serial ports at the controller faceplate.
  • Separates watchdog, memory, network, flash and startup status through dedicated indicators.
IS200ACLEH1A forms the base carrier layer between the PC/104 processor and the EX2100 control-rack backplane.

The ENET1 and COM1 paths on IS200ACLEH1A support controller setup without merging configuration traffic with the second network and serial channels.

Compact-flash access and startup progress remain visible at the IS200ACLEH1A faceplate while the storage device stays secured at P9 on the carrier.

Apter Power provides quotation and system-matching support for the General Electric IS200ACLEH1A Application Control Layer Carrier Board.
General Electric IS200ACLEH1A Application Control Layer Carrier Board Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Port Roles

  • Network pair: IS200ACLEH1A presents ENET1 and ENET2 through RJ-45 connectors.
  • Primary path: ENET1 carries Toolbox communication and the unit data highway connection.
  • Serial access: COM1 and COM2 use industry-standard DB9 connectors.
  • Commissioning link: COM1 accepts initial ENET1 TCP/IP settings from the Toolbox serial loader.

Load Structure

  • Core load: The operating system, file system and TCP/IP components reside on compact flash.
  • Runtime transfer: Controller runtime code is downloaded through ENET1.
  • Application data: Toolbox records application configuration as Pcode for volatile or flash storage.
  • BIOS settings: Processor-board configuration is preprogrammed and requires no normal adjustment on IS200ACLEH1A.

Indicator Meaning

  • OK: The green lamp comes on after startup when the watchdog timer is enabled.
  • ACTIVE: Memory access makes the green indicator blink or remain on while application code runs.
  • ENET: Activity on ENET1 drives the network lamp; ENET2 has no separate faceplate lamp.
  • FLASH and STATUS: Red flash access and the green startup-code sequence distinguish storage activity from diagnostic progress.

Board Connections

  • Processor coupling: Board-to-board headers and five ribbon cables join IS200ACLEH1A to the PC/104 processor.
  • Storage socket: P9 holds the compact-flash disk on the carrier board.
  • Backplane route: P1 carries the EX2100 rack connection and requires a custom extender for pin access.
  • Factory boundary: P15 remains unconnected during normal installation because it is reserved for production test.
Description
General Electric IS200ACLEH1A is the carrier board within an EX2100 Application Control Layer assembly. The board links the PC/104 processor portion of the controller to the control-rack backplane and brings the user communication connections to the ACLE faceplate.

Two RJ-45 Ethernet channels and two DB9 serial channels are routed by IS200ACLEH1A. ENET1 provides the normal Toolbox and unit-data-highway path, while ENET2 is available for a separate network; COM1 supports initial Ethernet addressing and diagnostics, and COM2 provides the second serial channel.

Compact-flash storage is seated at P9 on IS200ACLEH1A. Ribbon interfaces divide the carrier functions between reset at P6, compact flash at P3, ENET2 at P13, COM1 at P5 and COM2 at P4, with no adjustable jumpers fitted to the carrier board.

Front-panel indications associated with IS200ACLEH1A separate watchdog status, processor memory activity, ENET1 traffic, flash access and startup diagnostics. The recessed RST control resets the ACLE locally without resetting the entire backplane, and P15 remains disconnected during normal installation because it is reserved for factory test.
Alternative Names
IS200-ACLEH1A General Electric IS200ACLEH1A IS 200 ACLEH1A GE IS200ACLEH1A IS200 ACLE H1A EX2100 ACLE Carrier Board IS200ACLE H1A IS200ACLEHIA
Technical notes
General Electric IS200ACLEH1A carries the ACLE communication, compact-flash and backplane interfaces for an EX2100 control rack.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why is the red FLASH indicator on IS200ACLEH1A still on after a software transfer, and can control power be removed?
A lit FLASH indicator means IS200ACLEH1A is reading or writing compact flash. Keep power applied until the indicator goes out to avoid corrupting the flash file system.
A laptop connected directly to IS200ACLEH1A does not establish an Ethernet link. What cable arrangement should be checked first?
A direct computer-to-IS200ACLEH1A Ethernet connection requires a crossover cable; the standard straight-through arrangement is intended for a network device between the endpoints.
Toolbox cannot reach IS200ACLEH1A through ENET1 after the network address was lost. Which interface restores the initial settings?
Use the COM1 serial connection on IS200ACLEH1A with the Toolbox serial loader to enter the ENET1 TCP/IP settings before returning to Ethernet communication.
Why does network traffic on ENET2 fail to blink the ENET lamp on IS200ACLEH1A?
The faceplate ENET lamp on IS200ACLEH1A reports activity for ENET1 only. ENET2 has no corresponding faceplate activity indicator.
The STATUS lights on IS200ACLEH1A stop their walking pattern during startup. What does that indicate?
When one IS200ACLEH1A STATUS light remains fixed instead of advancing, startup has stalled; a flashing code indicates an application-load fault, while a steady code identifies a BIOS startup fault.
Will pressing the recessed RST control on IS200ACLEH1A restart every board in the EX2100 rack?
No. The recessed RST control resets IS200ACLEH1A only and does not reset the complete backplane or the other boards installed in the rack.

Product Browsing History