FCD311PT4P66STR1DCF00T62C0

/ 4.9
1001 reviews | Need a Specific Revision?
Danfoss FCD311PT4P66STR1DCF00T62C0 is a 1.1 kW VLT FCD 300 Series decentralized drive for 380–480 V three-phase motor-control systems.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for FCD311PT4P66STR1DCF00T62C0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FCD311PT4P66STR1DCF00T62C0

  • Manufacturer:
    Danfoss
  • Part Number:
    FCD311PT4P66STR1DCF00T62C0
  • Product Family:
    Danfoss
  • Product Type:
    VLT FCD 300 Series Decentral Drive
  • Stock:
    1
  • Supply Class:
    T4 — 380–480 V AC, three phase
  • Enclosure:
    P66 — IP66
  • Hardware Version:
    ST — Standard
  • RFI Filter:
    R1 — A1 RFI filter
  • Display Option:
    DC — Display connector
  • Fieldbus:
    F00 — No fieldbus
  • Mounting / Switch:
    T62 — Wall mount, metric, double-sided service switch
  • Coating:
    C0 — Non-coated
  • Rated Output Current:
    3.0 A
  • Maximum Output Current:
    4.8 A for 60 s
  • Maximum Input Current:
    2.6 A; 4.2 A maximum stated in rating data
  • Rated Apparent Power:
    2.0 kVA
  • Output Frequency:
    0.2–132 Hz or 1–1000 Hz
  • Ramp Time:
    0.02–3600 s
  • Efficiency:
    96%
  • Power Loss:
    59 W
  • Ambient Temperature:
    40 °C maximum; 35 °C 24-hour average
  • Relative Humidity:
    Up to 95%
  • Maximum Installation Altitude:
    1000 m without derating
  • Maximum Motor Cable:
    10 m
  • Dimensions:
    21x15x30.5cm
  • Weight:
    5.8 kg
  • Tariff Code:
    8467299000
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Type Code Electrical Installation Application
  • FCD 311 rating for 1.1 kW / 1.5 hp motor control
  • 380–480 V three-phase input with IP66 enclosure
  • T62 wall-mount configuration with metric double-sided service switch

FCD 311 FCD311PT4P66STR1DCF00T62C0 is a Danfoss decentralized drive in the VLT FCD 300 family.

Its type code defines the process-control version, voltage class, enclosure, RFI filter, display connection, communication choice, mounting arrangement, service switch and coating option.

Before installation or replacement, verify the complete type code, regional supply, motor current, mounting format, switch arrangement, cable routing, parameter backup, and current Danfoss lifecycle position.

Availability, condition, price, and shipping time for FCD 311 FCD311PT4P66STR1DCF00T62C0 are confirmed during quotation.

Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0 Decentral Drive Manuals, Product Family, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • P, T4 and P66 identify the process version, 380–480 V three-phase supply and IP66 enclosure
  • ST, R1 and DC identify standard hardware, A1 RFI filter and display connector
  • F00, T62 and C0 identify no fieldbus, wall-mount metric double-sided service switch and non-coated construction
  • FCD 311 is rated for 1.1 kW / 1.5 hp
  • The rated output current is 3.0 A with 4.8 A available for 60 seconds
  • The documented output-frequency ranges are 0.2–132 Hz and 1–1000 Hz
  • The P66 enclosure option is rated IP66
  • The T62 code specifies wall mounting with a metric double-sided service switch
  • The documented maximum motor-cable length is 10 m
  • Decentralized conveyor motor control
  • Distributed material-handling drive systems
  • Local motor control in process machinery requiring an IP66 enclosure
Description
FCD 311 FCD311PT4P66STR1DCF00T62C0 is a Danfoss VLT FCD 300 Series decentralized variable-frequency drive configured as an FCD 311 process unit for 380–480 V three-phase supply.

The type code specifies an IP66 standard enclosure, A1 RFI filter, display connector, no fieldbus option, and T62 wall mounting with metric double-sided service switch; the FCD 311 rating is 1.1 kW / 1.5 hp with 3.0 A rated output.

Before installation or replacement, match the complete type code, supply voltage, motor rating, enclosure, RFI option, display connection, fieldbus selection, T62 mounting and service-switch arrangement, wiring, parameter set, and regional lifecycle availability.
Alternative Names
FCD 311 FCD311PT4P66STR1DCF00T62C0 FCD311PT4P66STR1DCF00T62C0 FCD 311 P T4 P66 ST R1 DC F00 T62 C0 Danfoss FCD 311 VLT FCD 311 Danfoss VLT FCD 311 VLT Decentral Drive FCD 311 FCD 300 Series FCD 311
Technical notes
Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0 decodes to an IP66 T4 FCD 311 without fieldbus; match T62 switching, motor data, wiring, and saved parameters.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What configuration is encoded by Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0?
The code identifies an FCD 311 process drive for 380–480 V three-phase supply with IP66 enclosure, standard hardware, A1 RFI filter, display connector, no fieldbus, T62 wall mounting with metric double-sided service switch, and no conformal coating.
Can Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0 be replaced by another FCD 311 with a shorter type code?
Not without an engineering comparison. The suffix fixes enclosure, RFI, display, communication, mounting, service-switch and coating choices that may differ on another FCD 311.
What does the T62 section of Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0 change?
T62 identifies the wall-mount metric version with a double-sided service switch. Match the mechanical layout, switch access, cable entries and isolation arrangement before ordering.
Does Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0 include a fieldbus option?
No. F00 means no fieldbus option in the decoded type code. Confirm how the installed unit receives commands and status signals before replacement.
Which motor rating should be checked for Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0?
FCD 311 is the 1.1 kW / 1.5 hp size with 3.0 A rated output in the official ratings. Also match motor nameplate current, supply voltage, overload duty and parameter settings.
How should motor rotation be corrected on Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0?
The standard clockwise connection uses motor terminals 96/U, 97/V and 98/W. After isolating the drive and confirming that the DC link is discharged, reverse the rotation by interchanging any two motor-phase conductors.
How should unintended starting be prevented when servicing Danfoss FCD 311 FCD311PT4P66STR1DCF00T62C0?
Isolate the drive from the mains and wait for the specified DC-link discharge time before service. The motor can restart from an external switch, input reference or cleared fault even when the local display does not issue a start command.