ebm-papst G2E140-PI51-09 is a single-phase AC centrifugal blower for built-in air-conveying applications.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for G2E140-PI51-09
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for G2E140-PI51-09

  • Manufacturer:
    EBMPAPST
  • Part Number:
    G2E140-PI51-09
  • Product Family:
    EBMPAPST
  • Product Type:
    Single-Phase Centrifugal Blower
  • Stock:
    1
  • Nominal blower size:
    140 mm
  • Motor size:
    68
  • Phase:
    Single-phase
  • Nominal voltage:
    230 VAC
  • Frequency:
    50/60 Hz
  • Speed:
    2200 rpm at 50 Hz; 2100 rpm at 60 Hz
  • Power consumption:
    180 W at 50 Hz; 225 W at 60 Hz
  • Current draw:
    0.80 A at 50 Hz; 0.99 A at 60 Hz
  • Motor capacitor:
    4 µF
  • Capacitor voltage:
    450 VDB
  • Capacitor safety class:
    S2 (CE)
  • Operating ambient temperature:
    -25 to +60°C at 50 Hz; -25 to +40°C at 60 Hz
  • Permitted ambient air pressure:
    800–1050 mbar
  • Direction of rotation:
    Clockwise, viewed toward the rotor
  • Degree of protection:
    IP44, installation- and position-dependent, per EN 60034-5
  • Insulation class:
    Class B
  • Environmental protection class:
    H1
  • Installation position:
    Shaft horizontal or rotor on bottom; rotor on top on request
  • Condensation drainage holes:
    On rotor side
  • Operating mode:
    S1 continuous duty
  • Motor bearing:
    Ball bearing
  • Touch current:
    <0.75 mA per IEC 60990, measuring circuit Fig. 4, TN system
  • Cable assembly:
    PVC 6G AWG20 cable with Wago 231-608/019-000 connector housing and six crimped splices
  • Recommended cable temperature rating:
    105°C
  • Minimum conductor cross-section:
    AWG 26 / 0.13 mm²
  • Motor protection:
    Thermal overload protector (TOP) with basic insulation and cable
  • Protection class:
    Class I with customer protective-earth connection
  • Impeller material:
    Sheet steel, painted black
  • Housing material:
    Galvanized sheet steel
  • Maximum cyclic speed loads:
    1,000,000 load cycles
  • Mounting screw strength class:
    8.8
  • Storage and transport temperature:
    -40 to +80°C
  • Ball-bearing lifetime lubrication design:
    40,000 operating hours
  • Dimensions:
    21.7 × 24.5 × 13.0 cm
  • Weight:
    3.575 kg
  • Tariff Code:
    8414593000
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Mounting Safety Maintenance Application
  • 230 VAC single-phase centrifugal blower with an M2E068-DF motor
  • 50/60 Hz operation with continuous S1 duty
  • Sheet-steel impeller, galvanized housing and ball-bearing motor construction

G2E140-PI51-09 is an ebm-papst single-phase AC centrifugal blower designed for integration into customer-built air-conveying equipment.

The blower combines a scroll housing, clockwise-rotating impeller, connector cable, motor capacitor and winding-mounted thermal overload protector for continuous air movement.

Before installation or replacement, verify the complete model, supply frequency, ambient-temperature limit, mounting orientation, capacitor rating, protective-earth connection, thermal-protector wiring and mechanical guarding.

Availability, condition, price, and shipping time for G2E140-PI51-09 are confirmed during quotation.

ebm-papst G2E140-PI51-09 Centrifugal Blower Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Install with the shaft horizontal or with the rotor positioned at the bottom.
  • A rotor-up mounting position requires prior confirmation from ebm-papst.
  • Use strength-class 8.8 mounting screws, secure them against loosening and keep the rotor-side drainage holes clear.
  • Connect the winding-mounted thermal overload protector to an external control circuit that prevents automatic restart after a trip.
  • Connect and verify the protective earth before applying power to this Class I device.
  • Supply the blower only through a circuit equipped with an all-pole disconnection switch.
  • Inspect the guard, impeller, housing, cables, protective-earth terminal, drainage holes and bearing noise at least every six months.
  • Do not use high-pressure water, acids, alkalis, solvents or sharp-edged tools for cleaning.
  • The maintenance-free ball bearings use lifetime lubrication designed for 40,000 operating hours.
  • Cooling ABB ACS880-604 brake-chopper assemblies using NBRA-658 modules
  • Cooling ABB ACS880-604 brake-chopper assemblies using NBRA-659 modules
  • Cooling ABB ACS880-604 brake-chopper assemblies using NBRA-669 modules
Description
G2E140-PI51-09 is an ebm-papst single-phase AC centrifugal blower designed for built-in air-conveying applications in customer equipment.

The blower uses an M2E068-DF motor and operates from 230 VAC at 50 or 60 Hz, with S1 continuous duty, ball bearings, a 4 µF motor capacitor, and thermal-overload protection.

Before installation or replacement, confirm the complete model, supply frequency, applicable ambient-temperature limit, mounting position, capacitor rating, protective-earth connection, thermal-protector wiring, airflow clearance, and guarding requirements.
Alternative Names
ebm-papst G2E140-PI51-09 EBM-Papst G2E140-PI51-09 G2E140PI5109 G2E140 PI51 09 G2E140-PI51-09 230 VAC Blower M2E068-DF G2E140-PI51-09 ebm-papst 12599-5-9970
Technical notes
G2E140-PI51-09 requires correct thermal-overload, protective-earth, and 4 µF capacitor connections. Verify mounting orientation, airflow clearance, guarding, and the frequency-specific ambient-temperature limit before commissioning.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Can G2E140-PI51-09 be installed with the rotor above the motor?
The standard permitted positions are shaft-horizontal or rotor-down. A rotor-up installation requires confirmation from ebm-papst before use.
How does supply frequency affect the permitted ambient temperature of G2E140-PI51-09?
The maximum is +60°C at 50 Hz but only +40°C at 60 Hz. The installation must follow the limit corresponding to its actual supply frequency.
How must the thermal overload protector of G2E140-PI51-09 be integrated?
The winding-mounted protector must be connected to the external control circuit so a trip prevents the motor from restarting automatically after it cools.
Can G2E140-PI51-09 be operated from a variable-frequency drive?
Only after consultation with ebm-papst. An all-pole sine filter covering phase-to-phase and phase-to-ground paths is required between the drive and motor.
What must be checked when replacing the motor capacitor for G2E140-PI51-09?
Use a capacitor matching the documented 4 µF, 450 VDB and S2 requirements, confirm it against the nameplate, and discharge it before servicing the blower.
What electrical isolation and grounding provisions are required for G2E140-PI51-09?
As a Class I device, it requires a verified protective-earth connection and a supply circuit equipped with an all-pole disconnection switch.
What maintenance is recommended for G2E140-PI51-09 after storage and during service?
After extended inactivity, operate it for at least two hours to move the bearings and evaporate condensation. Inspect the guard, impeller, housing, cables, protective earth, drainage holes and bearing noise at least every six months.