SNAP-AIV-8
SNAP-AIV-8
SNAP-AIV-8
SNAP-AIV-8
SNAP-AIV-8
SNAP-AIV-8
Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power provides quotations, official datasheet access, and exact-model matching for SNAP-AIV-8.

SNAP-AIV-8

/ 4.9
1001 reviews | Need a Specific Revision?
Opto 22 SNAP-AIV-8 is an eight-channel SNAP PAC analog voltage input module that converts -10 to +10 V or -5 to +5 V field signals into controller input data.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for SNAP-AIV-8
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for SNAP-AIV-8

  • Manufacturer:
    OPTO22
  • Part Number:
    SNAP-AIV-8
  • Product Family:
    OPTO22
  • Product Type:
    Analog Voltage Input Module
  • Stock:
    1
  • Selectable input ranges:
    -10 to +10 V DC; -5 to +5 V DC
  • Over-range limits:
    -11 to +11 V; -5.5 to +5.5 V
  • Resolution:
    0.4 mV at ±10 V; 0.2 mV at ±5 V
  • Input filtering:
    -3 dB at 64 Hz
  • Maximum data freshness:
    0.28 s
  • DC common-mode rejection:
    >-120 dB
  • AC common-mode rejection:
    >-120 dB at 60 Hz
  • Maximum survivable input:
    220 V AC or 300 V DC
  • Maximum operating common-mode voltage:
    250 V
  • Accuracy:
    0.05%; 5 mV at 10 V DC; 2.5 mV at 5 V DC
  • Isolation:
    1500 V module-to-system
  • Rack power requirement:
    5 V DC ±0.15 V at 170 mA
  • Input resistance:
    1 MΩ; shared reference point
  • Operating temperature:
    -20 to +70 °C
  • Storage temperature:
    -40 to +85 °C
  • Humidity:
    5-95%, non-condensing
  • Connector screw torque:
    1.7 in-lb (0.19 N·m)
  • Estimated shipping dimensions:
    8.26x9x1.88cm
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input Ranges Reference Wiring Signal Timing Rack Installation

Features:

  • Converts eight single-ended field voltage signals for a SNAP PAC controller or brain.
  • Allows each channel to use either a ±10 V or ±5 V measurement range.
  • Isolates the complete module from the rack processor while all channels share one reference.
Opto 22 SNAP-AIV-8 places eight voltage channels in one SNAP PAC rack position and supplies their converted values to the installed processor.

Range selection changes the accepted span and measurement resolution without changing the shared-reference wiring arrangement.

Rack power, data freshness, common-mode voltage, and ambient limits define the boundary for integrating the module with field sources.

The Opto 22 SNAP-AIV-8 Analog Voltage Input Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Opto 22 SNAP-AIV-8 Analog Voltage Input Module Manuals,Datasheets,LinkImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Channel span and resolution

  • Wide range: Each input can measure from -10 to +10 V DC.
  • Narrow range: Each input can instead measure from -5 to +5 V DC.
  • Wide-range increment: The ±10 V configuration resolves 0.4 mV.
  • Narrow-range increment: The ±5 V configuration resolves 0.2 mV.

Shared return organization

  • Eight inputs: Channels 0 through 7 terminate on the two front connectors.
  • Common reference: All channels use one electrical reference point.
  • Internal terminals: Reference terminals 2, 4, 6, and 8 are internally connected on both connectors.
  • Isolation boundary: The module is isolated from the rack processor, not between individual channels.

Conversion and rejection limits

  • Freshness: A changed field value is reflected within the 0.28 s maximum data-freshness interval.
  • Filter: The input response is filtered at -3 dB at 64 Hz.
  • DC rejection: Documented common-mode rejection is greater than -120 dB.
  • AC rejection: Common-mode rejection remains greater than -120 dB at 60 Hz.

Position, power, and fastening

  • Rack position: The module can occupy any SNAP PAC rack module connector.
  • Processor pairing: SNAP PAC brains and R-series rack controllers support the eight-channel input module.
  • Rack supply: The module draws 170 mA from a 5 V DC ±0.15 V source.
  • Fastening: Hold-down screws are limited to 1 in-lb and connector screws to 1.7 in-lb.
Description
Opto 22 SNAP-AIV-8 is an eight-channel analog voltage input module for SNAP PAC brains and rack-mounted controllers. It receives field voltage on eight single-ended channels and transfers the converted values through the SNAP rack to the control strategy.

Each channel of SNAP-AIV-8 can be configured for either -10 to +10 V DC or -5 to +5 V DC operation. The wider range resolves 0.4 mV steps, while the narrower range resolves 0.2 mV steps, so the selected range determines both accepted span and measurement increment.

All eight inputs on SNAP-AIV-8 share one reference point. The module applies a -3 dB input filter at 64 Hz and refreshes converted data within 0.28 seconds, while the common-mode limits define the voltage relationship that the shared channels may have to the rack electronics.

Installed in any SNAP PAC rack position, SNAP-AIV-8 draws 170 mA from the 5 V DC rack supply and provides 1500 V isolation from other modules and the I/O processor. The isolation boundary is module-to-system rather than channel-to-channel, so every connected source must remain compatible with the common reference terminal.
Alternative Names
SNAPAIV8 SNAP AIV 8 SNAP-AIV 8 OPTO22 SNAP-AIV-8 Opto 22 SNAP AIV 8 SNAP-AIV-8 Analog Input Module SNAP-A1V-8 SNAP-AIV-B
Technical notes
Opto 22 SNAP-AIV-8 is the eight-channel shared-reference voltage-input execution documented in Form 1065; keep the complete -8 suffix when matching channel count and rack compatibility.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Which voltage ranges can be assigned to Opto 22 SNAP-AIV-8?
Opto 22 SNAP-AIV-8 lets each of its eight channels use either -10 to +10 V DC or -5 to +5 V DC, so the configured range must match the connected source.
Does Opto 22 SNAP-AIV-8 isolate every channel from the others?
No. Opto 22 SNAP-AIV-8 isolates the complete module from the rack processor, but all eight field channels share one reference point.
How quickly can Opto 22 SNAP-AIV-8 report a changed signal?
The maximum data-freshness interval of Opto 22 SNAP-AIV-8 is 0.28 seconds, which should be checked against the required update rate before selection.
What happens to resolution when Opto 22 SNAP-AIV-8 uses the ±5 V range?
On the ±5 V range, Opto 22 SNAP-AIV-8 resolves 0.2 mV rather than the 0.4 mV increment used for the ±10 V range.
Which rack processors are documented for Opto 22 SNAP-AIV-8?
Opto 22 SNAP-AIV-8 is documented for SNAP PAC brains and R-series rack-mounted controllers, including standard wired and Wired+Wireless models.
What wiring detail must be checked before landing sources on Opto 22 SNAP-AIV-8?
Because Opto 22 SNAP-AIV-8 internally joins the reference terminals, every source must be compatible with the shared reference and 250 V maximum operating common-mode limit.