Emerson EZ1081-07-00-010 EZ1901-090 is a 10.0 m armored AMS EZ 1000 eddy-current measuring chain.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for EZ1081-07-00-010 EZ1901-090
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for EZ1081-07-00-010 EZ1901-090

  • Manufacturer:
    Emerson
  • Part Number:
    EZ1081-07-00-010 EZ1901-090
  • Product Family:
    Epro
  • Product Type:
    8 mm Armored Eddy-Current Sensor and Armored Extension Cable Assembly
  • Stock:
    1
  • Sensor case thread:
    None; armored EZ1081 case
  • Sensor case length:
    70 mm
  • Unthreaded length:
    0 mm
  • Integral sensor cable:
    1.0 m
  • Extension cable:
    9.0 m armored EZ1901
  • Overall system length:
    10.0 m; valid under the official ordering rule
  • Linear range:
    2 mm
  • Initial gap:
    0.5 mm
  • Nominal scale:
    7.87 V/mm API or 8 V/mm ISO, converter configuration dependent
  • Sensor protection:
    IP67; IP68 only when DOC-TEST is assigned
  • Sensor/first 1 m temperature:
    -35 to 180°C
  • Cable/connector temperature:
    -35 to 150°C
  • Target material:
    AISI/SAE 4140 reference steel
  • Tariff Code:
    9031809090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Long-Reach Fit System Length Dynamic Check Application
  • Keep both exact component numbers and the 10.0 m total system length
  • Verify the 70 mm sensor case suits the bracket and target reach
  • Field-calibrate the complete sensor, cable and converter chain

Emerson EZ1081-07-00-010 EZ1901-090 combines an armored EZ1081 8 mm eddy-current sensor with an armored EZ1901 extension cable for a documented 10.0 m system length.

The exact components specify a 70 mm sensor case, 0 mm unthreaded section, 1.0 m integral sensor cable and 9.0 m extension cable.

Before installation, verify converter compatibility, the longer 70 mm case reach, bracket stiffness and 10 m cable route, target material and diameter, bracket geometry, connector sealing, cable route, total electrical length and field calibration.

Availability, condition, price, and shipping time for EZ1081-07-00-010 EZ1901-090 are confirmed during quotation.

Emerson EZ1081-07-00-010 EZ1901-090 Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Support the 70 mm armored case with a rigid bracket
  • Avoid side load and excessive unsupported length
  • Check clearance over the complete shaft movement envelope
  • Combine the 1 m sensor lead with the 9 m extension
  • Keep the total electrical length at the documented 10 m
  • Do not cut, splice or substitute a random cable
  • Check bracket resonance before interpreting vibration
  • Field-calibrate with the actual target and converter
  • Record baseline bias and vibration during controlled run-up
  • Radial shaft vibration measurement on turbines and compressors
  • Axial position or differential movement measurement
  • Speed, key and eccentricity sensing with the configured AMS EZ 1000 converter
Description
EZ1081-07-00-010 EZ1901-090 is an Emerson/epro AMS EZ 1000 eddy-current measuring chain formed by two separately ordered components.

The exact order codes define a 70 mm armored sensor with a 1.0 m integral cable and a 9.0 m armored extension cable; retain a rigid bracket and do not substitute another length without confirming converter scaling.

Before installation, confirm converter compatibility, target material, bracket stiffness and connector sealing, then set the probe gap and field-calibrate the complete chain.
Alternative Names
EZ1081-07-00-010 EZ1901-090 EZ1081 07 00 010 EZ1901 090 Emerson EZ1081-07-00-010 EZ1901-090 Epro EZ1081-07-00-010 EZ1901-090 Emerson Epro EZ1081-07-00-010 EZ1901-090 AMS EZ 1000 EZ1081-07-00-010 EZ1901-090
Technical notes
Emerson EZ1081-07-00-010 EZ1901-090 forms a documented 10.0 m measuring chain. Confirm both components, AMS EZ 1000 compatibility, sealing and field calibration before use.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When is the 70 mm case in Emerson EZ1081-07-00-010 EZ1901-090 appropriate?
Use the longer case when the bracket or housing requires additional reach, while controlling unsupported length, side load, vibration and surrounding metal clearance.
Can Emerson EZ1081-07-00-010 EZ1901-090 replace the 30 mm case version without reviewing the bracket?
No. The 70 mm case changes reach, stiffness and cable-exit position, so confirm holder geometry, support and the complete movement envelope.
Why does Emerson EZ1081-07-00-010 EZ1901-090 use the EZ1901-090 extension cable?
Its 9.0 m armored extension combines with the sensor's 1.0 m integral cable to form the documented 10.0 m measuring chain.
Why might Emerson EZ1081-07-00-010 EZ1901-090 indicate vibration that was not present with the previous probe?
A flexible or poorly supported long-reach bracket can add mechanical resonance. Inspect mounting rigidity, probe angle, lockup and target runout before changing electronics.
Can the cable in Emerson EZ1081-07-00-010 EZ1901-090 be shortened or spliced during installation?
No field alteration should be assumed. Preserve the documented 10.0 m electrical length and route excess cable within the approved bend-radius and strain limits.
What sealing and temperature checks apply to Emerson EZ1081-07-00-010 EZ1901-090 near hot or wet machinery?
Protect the inline connector, observe the separate sensor and cable temperature limits, and claim IP68 only when the required DOC-TEST and installation conditions are documented.
How should Emerson EZ1081-07-00-010 EZ1901-090 be validated after installation?
Check bracket resonance and clearance, calibrate the complete 10.0 m chain against the actual target, verify gap and polarity, and monitor the baseline and alarms during a controlled speed increase.