PR6423/003-031-CN CON041

/ 4.9
1001 reviews | Need a Specific Revision?
Emerson Epro PR6423/003-031-CN CON041 is a nameplate-confirmed 55 mm probe and DIN-rail converter assembly adjusted for 42CrMo4 target material.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for PR6423/003-031-CN CON041
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for PR6423/003-031-CN CON041

  • Manufacturer:
    Emerson
  • Part Number:
    PR6423/003-031-CN CON041
  • Product Family:
    Epro
  • Product Type:
    8 mm Eddy Current Sensor with DIN-Rail Converter
  • Stock:
    1
  • Nameplate probe type:
    PR6423/003-031-CN
  • Converter:
    CON041
  • Converter code:
    NC 9200-00021n
  • Adjustment material:
    42CrMo4
  • Marked protection:
    EEx ia IIC T4, Ta < 67°C
  • Base probe geometry:
    M10×1; 55 mm; unarmored
  • Lead and termination:
    8 m; open end
  • Weight:
    0.26 kg
  • Estimated shipping dimensions:
    18x18x2cm
  • Tariff Code:
    9031809090
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Matched Identity Target Calibration Ex Loop Limits Product Applications

Features:

  • Nameplate match: CON041 is explicitly adjusted for PR6423/003-031-CN.
  • Material calibration: the label identifies 42CrMo4 target material.
  • Protection marking: EEx ia IIC T4 with Ta below 67°C is shown on the supplied assembly.
The complete -CN identity is accepted from the Epro assembly nameplate rather than inferred from a family ordering table.

The base 003-031 geometry provides the 55 mm probe, adapter and 8 m open lead used with CON041.

The converter label, target material and protection marking remain part of the receiving and installed-system decision.

Apter Power supports Emerson PR6423/003-031-CN CON041 8 mm Eddy Current Sensor with DIN-Rail Converter quotations, technical documentation, procurement support and system-matching guidance.
Emerson PR6423/003-031-CN CON041 8 mm Eddy Current Sensor with DIN-Rail Converter Manuals,Datasheets,Link Important Notice: Apter Power provides these resources for exact-model documentation, quotation and engineering review.
  • Exact probe identity: the CON041 label names PR6423/003-031-CN, so the -CN suffix belongs in the replacement request rather than being dropped to the base 003-031 code.
  • Converter identity: NC 9200-00021n distinguishes the labelled unit from an unmarked CON041 when the installed chain is being matched.
  • Factory relationship: Emerson adjusts probe and converter as one measuring chain; their recorded pairing matters more than visual similarity between housings.
  • Cabinet interface: the CON041 format uses DIN-rail mounting and sensor screw terminals, defining the receiving connection for this labelled assembly.
  • Material on label: this converter is adjusted for 42CrMo4; that steel grade is the relevant basis for translating shaft distance into voltage.
  • Different shaft metal: conductivity and material properties change the eddy-current response, so another target material deserves a separate calibration decision.
  • Gap reference: the installed sensor position is set from the paired converter output, not from the visible probe length alone.
  • Service consequence: changing either member of the labelled pair calls for a fresh calibration decision before its output is treated as the prior channel baseline.
  • Protection marking: the supplied CON041 label carries EEx ia IIC T4; this describes the marked assembly rather than a blanket approval for every cabinet.
  • Ambient boundary: the same label states Ta below 67°C, which must be considered at the converter location.
  • Loop design: intrinsic-safety suitability depends on the associated barriers, wiring and complete installed circuit, not only the converter enclosure.
  • Identification at replacement: retaining the complete marked type and NC code helps the site assess whether a proposed unit preserves its approved loop configuration.
  • 42CrMo4 shaft monitoring: uses the nameplate adjustment basis for the installed target.
  • Hazardous-area loops: supports a documented intrinsically safe measurement installation.
  • Turbomachinery protection: conditions non-contact displacement or vibration data.
  • Exact-chain replacement: preserves the observed -CN identity and converter relationship.
Description
PR6423/003-031-CN CON041 is confirmed by the supplied Epro nameplate, which identifies a CON041 converter adjusted for PR6423/003-031-CN and 42CrMo4 target material.

The documented base configuration provides a 55 mm M10×1 unarmored probe, adapter plug, 8 m open lead and DIN-rail screw-terminal converter. The additional -CN marking is retained exactly as shown on PR6423/003-031-CN CON041; no unsupported meaning is assigned to it.

For PR6423/003-031-CN CON041 sourcing and recommissioning, compare the complete nameplate, converter code NC 9200-00021n and hazardous-area marking with the installed record. Preserve the matched chain and verify gap and output against the 42CrMo4 calibration basis.
Alternative Names
PR6423003031CNCON041 PR6423 003 031 CN CON041 PR6423-003-031-CN CON041 PR6423/003-031CN CON041 PR6423/003-031-CN-CON041 Emerson PR6423/003-031-CN CON041 Epro PR6423/003-031-CN CON041 PR6423/003-031-CN CON 041
Technical notes
The nameplate, not an inferred suffix expansion, controls PR6423/003-031-CN CON041 identity. It links CON041 code 9200-00021n to PR6423/003-031-CN, 42CrMo4 adjustment and the marked EEx ia IIC T4 ambient limit. Preserve the matching record and evaluate the complete hazardous-area installation before energizing the chain.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How is the exact identity of PR6423/003-031-CN CON041 confirmed?
The supplied Epro nameplate explicitly identifies CON041 adjusted for PR6423/003-031-CN, together with converter code 9200-00021n.
What does the -CN suffix mean on PR6423/003-031-CN CON041?
The available official ordering table does not define that suffix. We retain it exactly from the nameplate and avoid assigning an unsupported meaning.
Why does 42CrMo4 matter for PR6423/003-031-CN CON041?
Eddy-current calibration depends on target material, and the assembly label states adjustment for 42CrMo4. A different target requires engineering review.
Can PR6423/003-031-CN CON041 be accepted from a probe-only photograph?
We recommend confirming the converter nameplate, NC code, probe identity and connection arrangement because the supplied evidence defines a matched assembly.
What should be reviewed before using PR6423/003-031-CN CON041 in a hazardous area?
Confirm the complete intrinsic-safety loop, barriers, wiring, ambient conditions and site approvals against the marked EEx ia IIC T4 data.
Which commissioning checks are useful for PR6423/003-031-CN CON041?
Record the matched labels, cold gap, static output, target material, loop continuity and accepted dynamic baseline.