Features:
- Low-leakage 115 VAC input network for sensitive field circuits
- Eight configurable grouped circuits support mixed input and output use
- Electronic fusing and diagnostic functions are reset through the Genius system
IC660BBD101 is the low-leakage eight-circuit 115 VAC option and supersedes the older BBD100 grouped block in GE compatibility information.
The block supervises its power electronics locally, communicates circuit states over Genius, and supports redundant-control options where the system is configured accordingly.
For a field replacement, retain the complete catalog and revision markings and compare terminal assembly, configured I/O directions, input thresholds, output loads, and diagnostic settings.
The General Electric IC660BBD101 115 VAC Low-Leakage 8-Circuit Grouped I/O Block is available for quotation, official documentation, configuration review, and system-matching support from Apter Power.
General Electric IC660BBD101 115 VAC Low-Leakage 8-Circuit Grouped I/O Block Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC660BBD101 115 VAC Low-Leakage 8-Circuit Grouped I/O Block Specs
General
- ManufacturerGeneral Electric
- ModelIC660BBD101
- ConditionNew Original ready stock
- Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
AC input network
- Low-leakage path: The input network is intended for field devices sensitive to off-state current.
- Line supply: Operate the block only within the documented 115 VAC tolerance.
- Input threshold: Match sensor characteristics to the configured input behavior.
- Parallel devices: Review external switches or leakage-producing components before use.
Mixed I/O operation
- Direction setting: Program each circuit for input or output service.
- Filter selection: Choose 10 to 100 ms according to the process signal.
- Output feedback: Use diagnostics to compare commanded and actual output state.
- Redundancy option: Apply BSM and CPU redundancy settings only where the system supports them.
Diagnostic response
- Overtemperature: Remove excess loading or restore cooling before reset.
- Overload: Correct a shorted or excessive output load before re-enabling the point.
- No-load: Interpret the diagnostic with the actual circuit design in mind.
- Revision check: Pair terminal and electronics assemblies only as permitted by GE documentation.