Features:
- Processes pulse inputs directly at rates up to 200 kHz
- Configures as one complex, two medium, or four simple counters
- Includes twelve inputs, four outputs, an oscillator output, and a +5 VDC output
IC660BBD120 is the complete high-speed counter block; its terminal and electronics assemblies carry separate IC660TBD120 and IC660EBD120 identifiers.
Direct processing lets the block sense pulses, maintain counts, compare programmed limits, and change outputs without waiting for a bus exchange with the controller.
Select the counter structure only after identifying encoder signal levels, required count direction, pulse frequency, control inputs, output actions, and behavior during power interruption.
The General Electric IC660BBD120 High-Speed Counter Block is available for quotation, official documentation, configuration review, and system-matching support from Apter Power.
General Electric IC660BBD120 High-Speed Counter Block Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
General Electric IC660BBD120 High-Speed Counter Block Specs
General
- ManufacturerGeneral Electric
- ModelIC660BBD120
- ConditionNew Original ready stock
- Product FamilyGE Genius I/O
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Counting structures
- Simple mode: Configure four identical independent counters for separate pulse streams.
- Medium mode: Use two counters when each channel needs additional control functions.
- Complex mode: Select one counter for the most extensive input and output relationships.
- Direction: Count up, count down, combine directions, or measure a changing difference.
Signal acceptance
- Count rate: High-frequency operation supports pulses up to 200 kHz.
- Filter choice: Use 2.5 µs for fast signals or 12.5 ms for slower noisy inputs.
- Input style: Match single-ended or differential connections to the source device.
- Power level: Keep signal and load voltages inside the documented DC limits.
Local actions
- Controlled outputs: Four output circuits can respond to counter events.
- Oscillator: The dedicated output provides the documented timing signal.
- Auxiliary supply: A regulated +5 VDC point is available within its rated current.
- Backup: External battery operation can preserve the required counting behavior.