Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports IC660HHM501 pricing requests and access to applicable official General Electric Genius documentation.

IC660HHM501

/ 4.9
1001 reviews | Need a Specific Revision?
General Electric IC660HHM501 is a portable Genius operator interface for configuring devices, monitoring bus data, reviewing diagnostics, and controlling permitted maintenance functions.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC660HHM501
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC660HHM501

  • Manufacturer:
    General Electric
  • Part Number:
    IC660HHM501
  • Product Family:
    GE Genius I/O
  • Product Type:
    Genius Hand-held Monitor
  • Stock:
    1
  • Display:
    4 lines x 16 characters
  • Keyboard:
    20 sealed keys with tactile feedback
  • Display Languages:
    English, German, French, Italian
  • Data Rates:
    153.6 Kbaud standard/extended; 76.8 or 38.4 Kbaud
  • Battery Operation:
    6 hours fully charged
  • Charger Power:
    115/230 VAC, ±15%, 47-63 Hz
  • Operating Temperature:
    0 to 60 °C
  • Humidity:
    5-95% non-condensing
  • Weight:
    0.6 kg
  • Estimated shipping dimensions:
    20.32 x 9.53 x 3.18 cm
  • Tariff Code:
    8537109090
  • Country of origin:
    United States
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Operator Access Bus Monitoring Power Setup Compatibility

Features:

  • Four-line, 16-character LCD with selectable English, German, French, or Italian display
  • Genius device configuration, I/O monitoring, diagnostics, and permitted maintenance controls
  • Battery or charger operation with four supported Genius data rates
IC660HHM501 is a portable interface for technicians working directly with Genius I/O and communication devices.

Its display and keypad provide access to live values, device identity, faults, scan timing, Global Data, and selected host-CPU memory, while the keyswitch limits configuration authority.

Before use, match the HHM version to the attached device family, confirm the Genius data rate, and verify the battery, cable, connector, host selection, and permitted operating mode.

The General Electric IC660HHM501 Genius Hand-held Monitor is available for quotation, documentation support, and legacy Genius system assistance from Apter Power.
General Electric IC660HHM501 Genius Hand-held Monitor Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Keys and permissions

  • Configure mode: With the key in cfg, the complete set of permitted HHM setup functions is available.
  • Monitor mode: The mon position supports observation and only the additional actions enabled during HHM setup.
  • Function keys: Four context-sensitive keys use the bottom display line to identify their current action.
  • Security control: The key can be removed in monitor position to restrict access to configuration functions.

Visible system information

  • Device data: I/O values and device descriptions can be displayed for equipment on the selected Genius bus.
  • Diagnostics: Active Genius diagnostic information can be reviewed and applicable faults can be cleared.
  • Scan timing: Bus scan time is available to support communication and response-time review.
  • Host memory: Selected memory locations in compatible CPUs on the bus can be read from the handheld interface.

Battery and charger use

  • Battery requirement: A battery pack must remain installed even when the Hand-held Monitor operates from AC power.
  • AC selection: Set the charger for the incoming 115 V or 230 V source before connection.
  • Temporary recovery: A deeply discharged battery requires an initial charging period before AC-assisted operation is restored.
  • Operating time: A fully charged battery provides the documented six-hour operating period.

Version and device matching

  • Version suffix: The B, C, D, E, F, G, and J catalog suffixes identify documented HHM capability levels.
  • Block support: Some Genius blocks require a specified HHM version or later for complete configuration access.
  • Field Control: Field Control products require the IC660HHM501J v4.6 capability level in the documented compatibility table.
  • Upgrade path: Older HHM functionality can be expanded by replacing the firmware PROM according to the hardware instructions.
Description
IC660HHM501 is a portable Genius Hand-held Monitor that provides an operator interface at the equipment or along the communications bus. Its four-line display and keypad present system information in selectable English, German, French, or Italian.

Through IC660HHM501, an operator can view bus and device data, examine diagnostics, observe bus scan time, and read Global Data or supported CPU memory values. The unit also supports device configuration, fault clearing, forcing, and pulse-test functions where the connected Genius device permits them.

The keyswitch on IC660HHM501 separates monitoring access from configuration authority. This permits routine observation with restricted settings while allowing an authorized user to change device or bus parameters and perform checkout operations when required.

IC660HHM501 can be connected at a designated Genius bus point or used with the applicable connector and power accessories. Its battery remains part of the operating arrangement even when external AC power is used, allowing portable service activity to continue when the monitor is disconnected from the charger.
Revisions

Revision Part #

Also known as

IC660HHM501J
IC660HHM501-J, Series J, Rev J
IC660HHM501G
IC660HHM501-G, Series G, Rev G
IC660HHM501F
IC660HHM501-F, Series F, Rev F
IC660HHM501E
IC660HHM501-E, Series E, Rev E
IC660HHM501D
IC660HHM501-D, Series D, Rev D
IC660HHM501C
IC660HHM501-C, Series C, Rev C
IC660HHM501B
IC660HHM501-B, Series B, Rev B
Alternative Names
IC660 HHM 501 IC660-HHM-501 IC66OHHM501 1C660HHM501 General Electric IC660HHM501 GE Fanuc IC660HHM501 GE Genius IC660HHM501 Genius Hand-held Monitor IC660HHM501
Technical notes
IC660HHM501 may report communication errors at 38.4 Kbaud when its cable is unterminated or its selected baud rate differs from the bus.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can IC660HHM501 be connected to a Genius system?
IC660HHM501 can connect through a compatible I/O block, bus controller, or dedicated panel-mounted Genius HHM connector.
Which information can IC660HHM501 display from the bus?
IC660HHM501 can display I/O values, device descriptions, diagnostics, bus scan time, Global Data addresses, and selected CPU memory.
How does the keyswitch affect IC660HHM501 operation?
IC660HHM501 uses the keyswitch to separate full configuration access from monitor-mode functions that can be restricted for the application.
Which Genius bus data rates are supported by IC660HHM501?
IC660HHM501 supports 153.6 Kbaud standard and extended rates together with 76.8 Kbaud and 38.4 Kbaud operation.
How long can IC660HHM501 operate on a full battery charge?
IC660HHM501 is specified for six hours of operation from a fully charged battery pack under the documented conditions.
What should be checked when IC660HHM501 cannot communicate with a device?
For IC660HHM501, verify the bus cable, connector, baud rate, device address, selected host type, battery state, and access mode.
Can IC660HHM501 force or test I/O during maintenance?
IC660HHM501 supports permitted circuit forcing, pulse testing, fault clearing, and related maintenance functions when its access configuration allows them.