Technical specifications for IC695ALG608

  • Manufacturer:
    General Electric
  • Part Number:
    IC695ALG608
  • Product Family:
    GE PACSystems RX3i
  • Product Type:
    PACSystems RX3i Analog Input Module
  • Stock:
    1
  • Input architecture:
    Non-isolated analog current/voltage inputs
  • Channel modes:
    8 single-ended or 4 differential inputs
  • Current ranges:
    0...20 mA, 4...20 mA, and ±20 mA
  • Voltage ranges:
    ±10 V, 0...10 V, ±5 V, 0...5 V, and 1...5 V
  • Backplane:
    PACSystems RX3i Universal Backplane
  • Serviceability:
    Hot swappable
  • Compatible terminal blocks:
    IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132
  • Configuration:
    Software-configurable channel ranges and operating parameters
  • Calibration:
    Automatic calibration
  • Diagnostics:
    Onboard error checking and open-circuit detection
  • Channel processing:
    Per-channel scaling, offsets, alarms, and rate-of-change functions
  • Interrupts:
    Configurable channel alarms and rate-of-change interrupts
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Modes Diagnostics Alarms Application
  • Selectable single-ended or differential architecture supports different field-wiring needs
  • Software configuration assigns current or voltage operation by channel
  • Hot-swap capability supports controlled module service in an RX3i Universal Backplane

IC695ALG608 is a General Electric PACSystems RX3i Analog Input Module for non-isolated current and voltage measurement.

The module can be configured for eight single-ended points or four differential points and applies channel scaling, offsets, alarms, diagnostics, and rate-of-change processing in the RX3i system.

Before installation or replacement, verify the input mode, terminal block, loop wiring, common reference, range, scaling, alarms, filters, interrupt configuration, grounding, shielding, and saved project.

Availability, condition, price, and shipping time for IC695ALG608 are confirmed during quotation.

General Electric IC695ALG608 PACSystems RX3i Analog Input Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Eight single-ended inputs maximize channel count for common-referenced signals
  • Four differential inputs provide separate positive and negative measurement connections
  • Current and voltage operation is assigned through the RX3i software configuration
  • Automatic calibration compensates the module measurement path
  • Onboard error checking reports internal and configured channel conditions
  • Open-circuit detection can identify supported field-loop wiring faults
  • Per-channel scaling and offsets convert raw input values to engineering units
  • Configurable alarm limits support channel-specific process monitoring
  • Rate-of-change alarms and interrupts can report rapidly changing analog signals
  • Acquisition of 0...10 V and ±10 V industrial analog signals
  • Monitoring of 0...20 mA and 4...20 mA process transmitters
  • Differential voltage or current measurement in PACSystems RX3i control systems
Description
IC695ALG608 is a General Electric PACSystems RX3i Analog Input Module for non-isolated industrial current and voltage signals.

The module provides eight single-ended or four differential inputs, selectable current and voltage ranges, automatic calibration, open-circuit detection, per-channel scaling, alarms, and rate-of-change functions.

Before installation or replacement, confirm the complete catalog number, RX3i Universal Backplane, compatible terminal block, input mode, field-loop common, signal ranges, scaling, alarms, grounding, shielding, and saved configuration.
Revisions

Revision Part #

Also known as

IC695ALG608A
IC695ALG608-A, Series A, Rev A
IC695ALG608B
IC695ALG608-B, Series B, Rev B
IC695ALG608C
IC695ALG608-C, Series C, Rev C
IC695ALG608D
IC695ALG608-D, Series D, Rev D
IC695ALG608E
IC695ALG608-E, Series E, Rev E
IC695ALG608F
IC695ALG608-F, Series F, Rev F
IC695ALG608G
IC695ALG608-G, Series G, Rev G
IC695ALG608H
IC695ALG608-H, Series H, Rev H
IC695ALG608J
IC695ALG608-J, Series J, Rev J
IC695ALG608K
IC695ALG608-K, Series K, Rev K
IC695ALG608L
IC695ALG608-L, Series L, Rev L
Alternative Names
IC695ALG608 IC695 ALG608 GE IC695ALG608 General Electric IC695ALG608 PACSystems RX3i IC695ALG608
Technical notes
IC695ALG608 replacement requires the single-ended or differential mode, compatible terminal block, current or voltage ranges, loop commons, scaling, offsets, alarms, rate-of-change settings, grounding, and saved RX3i configuration to be verified.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When should General Electric IC695ALG608 use differential inputs?
Use the four-channel differential mode when the field signal requires separate positive and negative measurement connections. Confirm common-mode limits, grounding, and the project configuration.
Which terminal blocks fit General Electric IC695ALG608?
Emerson lists IC694TBB032, IC694TBB132, IC694TBS032, and IC694TBS132. The terminal block is ordered separately, so match screw or spring style and extended-depth requirements.
Can General Electric IC695ALG608 detect an open field circuit?
The module includes open-circuit detection for supported configurations. Confirm that the selected range, wiring, and diagnostic enablement provide the expected behavior for the installed loop.
Can General Electric IC695ALG608 be hot-swapped?
Yes. Follow the RX3i hot-swap procedure, maintain field-loop safety, seat and lock the terminal block, and verify module and channel diagnostics before restoring control.
Can General Electric IC695ALG608 generate an interrupt from a rapidly changing signal?
Yes. The module supports rate-of-change alarms and interrupts when configured in the RX3i project. Preserve the threshold, time base, and channel scaling during replacement.
Is General Electric IC695ALG608 an isolated analog input module?
No. Emerson identifies the inputs as non-isolated. Review field commons, grounding, shield termination, and external isolation requirements before connecting transmitters.
What information should accompany an inquiry for General Electric IC695ALG608?
Provide the single-ended or differential mode, terminal-block number, channel signal ranges, loop-power arrangement, scaling and alarm settings, RX3i rack details, and project version.