Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    For IC200UEC108, Apter Power assists with quotations, official product manuals and VersaMax expansion selection.

IC200UEC108

/ 4.9
1001 reviews | Need a Specific Revision?
Designed as an 8-point VersaMax Micro expansion unit, General Electric IC200UEC108 adds four 24 VDC inputs and four sinking transistor outputs to a supported controller.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for IC200UEC108
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for IC200UEC108

  • Manufacturer:
    General Electric
  • Part Number:
    IC200UEC108
  • Product Family:
    GE VersaMax
  • Product Type:
    VersaMax Micro 8-Point Sink I/O Expansion Unit
  • Stock:
    1
  • Input Points:
    4
  • Input Type:
    24 VDC positive/negative logic
  • Output Points:
    4
  • Output Type:
    24 VDC sinking transistor
  • Module Supply:
    24 VDC nominal; -20%/+25%
  • Output Load:
    0.7 A per point; 3 A per common
  • Output Response:
    0.05 ms maximum
  • Input Response:
    4 ms typical
  • Auxiliary 24 VDC:
    200 mA maximum
  • Isolation:
    1500 V RMS field-to-logic; 500 V RMS between groups
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Compatibility Field Wiring Output Safety Cabling

Features:

  • Adds four 24 VDC inputs and four sinking transistor outputs in one module.
  • Provides separate Power, OK and point-level LED indication.
  • Supports modular I/O growth on compatible VersaMax Micro controllers.
The sink-output arrangement completes the load path toward the field return and fits devices wired for that polarity.

A 24 VDC module supply powers local electronics, while the output loads use their own external field source through the common circuit.

Expansion connectors on both sides make the unit an intermediate or final member of a multi-module chain.

The General Electric IC200UEC108 VersaMax Micro 8-Point Expansion Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC200UEC108 VersaMax Micro Expansion Manuals, Datasheets, LinksImportant Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Supported Micro PLC Hosts

  • Controller Sizes: Compatible hosts range from 14-point through 64-point VersaMax Micro PLCs.
  • Mixed Chains: The controller can use supported expansion types in the same chain.
  • Maximum Count: No more than four expansion units may follow one base PLC.
  • Station Reach: Expansion hardware may be positioned within two meters of the controller.

Input and Common Arrangement

  • Logic Choice: Inputs accept positive- or negative-logic 24 VDC signals.
  • Common Wiring: The common connection must correspond to the selected sensor polarity.
  • Terminal Removal: Field conductors remain on the terminal assembly during module service.
  • Isolation: Field circuits are electrically separated from internal logic.

Sink Circuit Precautions

  • Current Direction: Each output provides the return path for a 24 VDC load.
  • External Fuse: Fast field fusing should interrupt short-circuit current before transistor damage occurs.
  • Point Limit: No output should exceed 0.7 A under normal operation.
  • Common Limit: Combined current on the shared common must remain at or below 3 A.

Expansion Cable Selection

  • Standard Cable: IC200CBL501 supplies the included 0.1 m connection.
  • Alternate Length: IC200CBL505 extends the link to 0.5 m.
  • One-Meter Option: IC200CBL510 is available for longer spacing.
  • Route Control: The complete chain must remain within the permitted two-meter distance.
Description
As an 8-point VersaMax Micro expansion unit, General Electric IC200UEC108 adds four 24 VDC inputs and four sinking transistor outputs to a compatible controller. The module extends the local I/O chain through dedicated left and right expansion connectors rather than through a separate fieldbus node.

Positive- or negative-logic input wiring can be selected to match the connected sensing devices. Local Power and OK LEDs show module condition, and individual point indicators let maintenance personnel compare the electrical field state with the controller image during troubleshooting.

The four outputs provide a current-sinking path for 24 VDC loads and require an external field supply. Fast external fusing should be fitted because an output short circuit can damage the internal, non-user-replaceable transistor; point and common current limits must also be observed when several loads operate together.
Alternative Names
VersaMax Expansion IC200UEC108 IC200UEC108 IC200 UEC 108 GE Fanuc IC200UEC108 IC200-UEC108 GE IC200UEC108 IC200 UEC108 IC200UECI08
Technical notes
General Electric IC200UEC108 adds four DC inputs and four sinking transistor outputs to a VersaMax Micro station. Provide fast external output fusing and observe common-current limits.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How many expansion units can share a station with General Electric IC200UEC108?
A compatible VersaMax Micro PLC can support up to four expansion units, including General Electric IC200UEC108. The final combination must also satisfy the controller compatibility, expansion-power and cable-distance limits.
Why should fast external fusing be installed for General Electric IC200UEC108?
A short circuit can damage the non-user-replaceable sinking transistors in General Electric IC200UEC108. Fit fast fuses appropriate to the field circuit and correct the cause of the fault before power is applied again.
How far may General Electric IC200UEC108 be placed from the base controller?
General Electric IC200UEC108 can be positioned within the documented two-meter expansion span. Build that route from approved 0.1, 0.5 or 1 m cables without exceeding the total permitted length.
What load polarity suits the outputs on General Electric IC200UEC108?
The four outputs of General Electric IC200UEC108 provide a sinking return path for 24 VDC field loads. Supply the positive side externally, wire the common correctly and keep point and shared-current demand within rating.
What do the LEDs on General Electric IC200UEC108 reveal during commissioning?
Separate Power and OK lamps report local supply and module condition on General Electric IC200UEC108, while one indicator per I/O point shows circuit state. Comparing those indications with the controller image helps narrow a fault to logic or field wiring.
How should PNP sensors be wired to the inputs of General Electric IC200UEC108?
For PNP devices, configure the input group on General Electric IC200UEC108 for the corresponding positive-logic arrangement and connect the common to complete the return path. Verify polarity and voltage before energizing the terminal assembly.