Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports HE800ACM200 sourcing, technical data and system matching.

HE800ACM200

/ 4.9
1001 reviews | Need a Specific Revision?
Horner HE800ACM200 is a SmartStack AC power monitor that provides three-phase voltage, current, phase and frequency data to Horner OCS/RCS control systems.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for HE800ACM200
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for HE800ACM200

  • Manufacturer:
    HORNER
  • Part Number:
    HE800ACM200
  • Product Family:
    HORNER
  • Product Type:
    AC Power Monitor Module
  • Stock:
    1
  • Voltage Input:
    120 V three-phase Wye; 208 V line-to-line; external PTs required
  • Current Input:
    Three-phase 5 A; external CTs required
  • Frequency Range:
    50–70 Hz
  • Measurement Accuracy:
    0.2% voltage and current
  • Resolution:
    0.1 V voltage; 0.005 A current; 0.01 Hz frequency
  • Required Power:
    1.5 W (60 mA at 24 VDC); 80 mA inrush
  • Operating Temperature:
    0–60 °C
  • Relative Humidity:
    5–95%, non-condensing
  • Weight:
    0.5625 lbs (0.256 kg)
  • Tariff Code:
    9030339000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Monitoring Installation I/O Programming Compatibility

Features:

  • Monitors three-phase voltage, current, phase and frequency.
  • Uses external 120 V PTs and three-phase 5 A CTs.
  • Maps measurement data to SmartStack controller input registers.
Horner HE800ACM200 is the metal-case ACM200 ordering configuration for SmartStack control systems. HE-ACM200 is the plastic-case configuration in the same product documentation.

The module supplies three-phase electrical measurements to OCS/RCS controllers and supports application calculations for apparent power, real power, power factor, reactive power and accumulated energy.

Phase and frequency are referenced to the L1 voltage channel. Transformer ratios, polarity, phase sequence and controller compatibility must match the intended SmartStack application.

The Horner HE800ACM200 AC power monitor may still be available for purchase and support from Apter Power.
Horner HE800ACM200 AC Power Monitor Manuals, Datasheets, Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

HE800ACM200 Measurement Performance

  • Voltage monitoring: The module measures 120 V three-phase Wye input, equivalent to 208 V line-to-line, through external potential transformers.
  • Current monitoring: Three-phase 5 A current inputs use external current transformers.
  • Phase and frequency: Phase and 50–70 Hz frequency measurements are referenced to the L1 voltage channel.
  • Measurement accuracy: Voltage and current accuracy is 0.2%, phase accuracy is 0.2°, and frequency accuracy is 0.1%.
  • Update timing: Voltage and current update once per PLC scan; phase and frequency update once per line cycle.

HE800ACM200 Installation Requirements

  • Voltage transformers: External PTs must supply the 120 V three-phase Wye measurement input.
  • Current transformers: Each phase uses an external CT with a 5 A secondary.
  • Current common: Each CT low input must return to common directly or through a suitable monitoring switch unit.
  • Connections: The module provides fixed front-access connectors with removable spring-clamp terminals.
  • Module power: Required power is 1.5 W, or 60 mA at 24 VDC, with 80 mA inrush current.

HE800ACM200 I/O Data and Calculations

  • Register allocation: Thirteen %AI registers carry the module measurement data, with allocation determined automatically by model and stack position.
  • Voltage data: L1, L2 and L3 voltage measurements are mapped to %AI1 through %AI3.
  • Current data: L1, L2 and L3 current measurements are mapped to %AI4 through %AI6.
  • Power calculations: Controller logic can calculate per-phase and total VA and watts, plus power factor and VAR, from the mapped values.
  • Energy accumulation: A timed calculation can accumulate kWh from the running watt-second total.

HE800ACM200 SmartStack Compatibility

  • Controller platforms: The module supplies measurement data to compatible Horner OCS and RCS systems that support SmartStack I/O.
  • Metal configuration: HE800ACM200 is the metal-case ACM200 ordering configuration.
  • Plastic configuration: HE-ACM200 is the corresponding plastic-case configuration; controller support for the selected housing must be verified.
  • Adjacent modules: Differential phase reports the relative L1 phase between the unit and the next lower adjacent ACM200 module.
Description
Horner HE800ACM200 is a SmartStack AC power monitor for three-phase electrical measurement in Horner OCS and RCS control systems. It accepts 120 V three-phase Wye voltage inputs, equivalent to 208 V line-to-line, and three 5 A current inputs through external potential and current transformers.

The module measures voltage and current as average values scaled to RMS sine-wave equivalents and provides 0.2% accuracy for both. It also captures phase and frequency across a 50–70 Hz range, with L1 voltage used as the phase and frequency reference.

The SmartStack I/O map makes individual L1–L3 voltage, current and phase values, differential phase and frequency available to controller logic. These data support calculation of per-phase and total volt-amperes, watts, power factor, VAR and accumulated kWh, allowing Horner HE800ACM200 to support power supervision, phase comparison and energy monitoring within automated equipment.
Alternative Names
HE-ACM200 HE 800 ACM 200 HE800 ACM200 Horner HE800ACM200 Horner APG HE800ACM200 SmartStack ACM200 Horner HE-ACM200 HE800ACM200 AC Power Monitor
Technical notes
Horner HE800ACM200 monitors three-phase voltage, current, frequency, phase and calculated power values in SmartStack OCS/RCS systems. External 120 V PTs and 5 A CTs are required.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can unstable current readings from Horner HE800ACM200 be diagnosed?
For Horner HE800ACM200, verify that each external CT has a 5 A secondary, the CT low side returns to common directly or through a suitable monitoring switch, the input frequency is 50–70 Hz, and the wiring follows MAN0351.
What should be checked when Horner HE800ACM200 voltage readings are incorrect?
For Horner HE800ACM200, confirm that external PTs provide 120 V three-phase Wye inputs, phase L1 is the reference, voltage common is wired correctly, and the controller scaling uses 0.1 V per count.
Why can Horner HE800ACM200 report incorrect phase or power factor values?
Horner HE800ACM200 references phase and frequency to the L1 voltage input. Check CT/PT polarity, phase sequence, adjacent-module differential phase, and the controller calculations that use the assigned voltage and current phase registers.
How can Horner HE800ACM200 compatibility with an existing OCS/RCS stack be verified?
For Horner HE800ACM200, identify the exact controller model, verify SmartStack support in its hardware manual, confirm an available stack position, and review the automatic Cscape I/O map before installation.
What must be checked before replacing Horner HE800ACM200 with Horner HE-ACM200?
Horner HE-ACM200 is the plastic-case version named in MAN0351. Before replacing Horner HE800ACM200, verify housing support, mounting, connectors, wiring, CT/PT requirements, and compatibility with the host controller.
How should Horner HE800ACM200 be installed safely in a power-monitoring circuit?
Before installing Horner HE800ACM200, de-energize the OCS, CAN port and connected equipment, open related breakers, connect protective earth first, fuse the voltage measurement inputs, and use qualified electrical personnel.
What information is needed to troubleshoot a Horner HE800ACM200 installation?
To troubleshoot Horner HE800ACM200, collect the controller model, Cscape I/O map, CT/PT ratings and polarity, terminal wiring, actual readings, operating temperature and fault symptoms, then compare them with MAN0351.