Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com

FBM219

/ 4.9
1001 reviews | Need a Specific Revision?
Foxboro FBM219 is a group-isolated discrete I/O interface module with 24 inputs and 8 outputs for Foxboro DCS field signals.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for FBM219
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for FBM219

  • Manufacturer:
    Invensys
  • Part Number:
    FBM219
  • Product Family:
    Foxboro
  • Product Type:
    24-Input/8-Output Discrete I/O Interface Module
  • Stock:
    1
  • Input/output channels:
    24 inputs and 8 outputs, group isolated
  • Filter/debounce:
    No filtering, 4, 8, 16 or 32 ms
  • Voltage-monitor ON state:
    15 to 30 VDC; 2.2 mA typical at 30 VDC
  • Voltage-monitor OFF state:
    0 to 5 VDC; 0.4 mA maximum at 5 VDC
  • Output switch with external source – Applied voltage:
    60 VDC maximum
  • Output switch with external source – Load current:
    0.25 A maximum
  • Output switch with external source – Off-state leakage:
    0.25 mA maximum
  • Isolation test:
    600 VAC for one minute between channel groups and ground
  • Input loop-power protection:
    2.5 mA current limit
  • Power consumption:
    6 W maximum at 24 VDC
  • Heat dissipation:
    5 W maximum at 24 VDC
  • Module Fieldbus:
    Redundant 2 Mbps
  • Input power:
    24 VDC +5%, -10%
  • Operating temperature:
    -20 to +70°C
  • Storage temperature:
    -40 to +70°C
  • Relative humidity:
    5 to 95%, noncondensing
  • Contamination class:
    ISA-S71.04 Class G3
  • Dimensions:
    10.2 × 4.5 × 10.4 cm
  • Weight:
    0.284 kg
  • Tariff Code:
    8538900000
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Input States Output Loads Termination Application
  • Use FBM219 only for the documented FBM219 channel function
  • Confirm the electronic-module order number, termination hardware and cable before replacement
  • Preserve field wiring, channel configuration, diagnostics and redundancy state before removal

FBM219 is a Foxboro 24-input/8-output discrete i/o interface module designed for Foxboro DCS 200 Series field I/O.

Foxboro FBM219 is a group-isolated discrete I/O interface module with 24 inputs and 8 outputs for Foxboro DCS field signals. FBM219 is the official functional model and RH916RH is its current exact module part number; termination assemblies and expansion assemblies are separate products.

Before installation or replacement, verify the complete nameplate, companion hardware, termination assembly, cable, signal limits, field wiring, saved configuration and supported system environment.

Availability, condition, price, and shipping time for FBM219 are confirmed during quotation.

Foxboro FBM219 24-Input/8-Output Discrete I/O Interface Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Apply only the voltage range supported by the selected termination assembly
  • Restore each channel's no-filter or 4/8/16/32 ms debounce value
  • Check shared field-power and group-isolation boundaries before energization
  • Keep direct external-source outputs within 60 VDC and 0.25 A
  • Add approved suppression across inductive loads
  • Use the correct relay termination arrangement for higher-current field loads
  • Match the main and expansion termination assemblies to RH916RH
  • Verify Type 4 and Type 6 cable identities where applicable
  • Keep module, main TA, expansion TA and field-power identities separate
  • Discrete status and voltage-monitor input acquisition
  • Low-current DC solenoid and relay output control
  • Mixed discrete input/output service using main and expansion termination assemblies
Description
FBM219 is a Foxboro 24-input/8-output discrete i/o interface module for the Foxboro DCS 200 Series I/O platform.

Foxboro FBM219 is a group-isolated discrete I/O interface module with 24 inputs and 8 outputs for Foxboro DCS field signals. Its documented channel architecture and electrical limits define the supported field interface.

Before installation or replacement, confirm the complete FBM219 identity, module part number, compatible termination hardware, cable, field power, wiring, saved configuration and control-system requirements.
Alternative Names
FBM219 FBM 219 Foxboro FBM219 Foxboro Evo FBM219 Invensys Foxboro FBM219 I/A Series FBM219 RH916RH FBM219 RH916RH
Technical notes
FBM219/RH916RH is a 24-input/8-output group-isolated module. Select the exact termination assembly for the required input voltage, output load and terminal style.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When is FBM219 a practical choice for a marshalling panel with many status signals and fewer field commands?
Use FBM219 when the approved design needs its asymmetric discrete input and output arrangement and group-isolated wiring. Confirm the termination assembly, common scheme and control database before selection.
What does the selected termination assembly change in an FBM219 isolation design?
FBM219 isolation depends on the selected termination assembly. Most arrangements isolate input and output groups from ground, while RH917LL/RH917LP input paths and RH917LS output paths provide channel isolation. Confirm the exact termination assembly before defining commons, grounding or fault segregation.
Why can several FBM219 inputs in the same group change state or fail together?
Look for a lost group common, unstable field supply, shared terminal fault, short circuit, grounding problem, damaged cable or configuration issue affecting the group rather than testing only one contact.
Why can FBM219 inputs read correctly while its output section remains unavailable?
The input and output field circuits can fail independently. Check the output field source, protection path, termination wiring, load condition, output assignments, interlocks and output diagnostics.
Can FBM219 replace a module with individually isolated channels without rewiring?
No. The isolation architecture, common wiring, termination assembly, cable and database may differ. Review fault segregation and field-power requirements before approving the substitution.
How should debounce be chosen for FBM219 contact inputs?
Balance the required response time against contact bounce and electrical noise, then test the setting with the real field device and process sequence instead of copying one value across every point.
What end-to-end test proves that an FBM219 marshalling change is correct?
Operate representative contacts from the field side, verify group commons and input logic, command each used output into a controlled load, then confirm interlocks, alarms, diagnostics and the final process response.