/ 4.9
1001 reviews | Need a Specific Revision?
Triconex 3617E provides eight commoned 48 VDC supervised outputs and can use a regulated 5 VDC secondary source to detect shorted loads while the outputs are off.
In Stock
Ships by Sunday, October 18
Fast Shipping Available
Get a quick price for 3617E
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 3617E

  • Manufacturer:
    Invensys
  • Part Number:
    3617E
  • Product Family:
    Triconex
  • Product Type:
    Supervised TMR Digital Output Module
  • Stock:
    1
  • Model:
    3617E
  • Architecture:
    TMR supervised digital output
  • Nominal voltage:
    48 VDC
  • Points:
    8 commoned
  • Voltage range:
    36 to 72 VDC
  • Frequency range:
    DC only
  • Maximum switching power:
    150 W resistive
  • Typical on-state drop:
    Less than 2 V
  • Maximum current per point:
    1 A
  • Surge current:
    5 A for 10 ms
  • Minimum required load:
    100 mA
  • Secondary supply:
    5.00 VDC ±0.25 VDC
  • Chassis leakage:
    Not applicable
  • Load leakage:
    4 mA maximum
  • Field termination fuse:
    1.25 A fast-acting, one per output
  • Point isolation:
    1,500 VDC minimum
  • Indicators:
    POINT, PWR, LOAD, PASS, FAULT, ACTIVE
  • Color code:
    Mint green
  • Hot spare:
    Supported
  • External termination:
    Separate ETP and cable required
  • Tariff Code:
    8537101190
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Applications Interoperability Protection Performance

Features:

  • Provides eight commoned 48 VDC outputs with relay-based TMR voting and continuous field supervision.
  • Uses a five-volt secondary source to extend short-circuit detection while a commanded output remains off.
  • Requires at least 100 mA of connected load and a 1.25-amp fuse at each supervised termination path.
Configured as the mint-green 48 VDC SDO module, 3617E combines eight commoned output points with hot-spare capability for Tricon chassis installations.

Its optional regulated secondary supply extends diagnostic coverage by exposing shorted field loads during the de-energized state, a function not provided by the 115 VAC version.

Select loads that remain within 1 A per point and meet the 100 mA supervision threshold; use the specified ETP, cable interface, and 1.25 A output fusing.

Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Triconex 3617E: Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Supervises 48 VDC shutdown coils whose field power, fuse and load continuity must remain observable during long dwell periods.
  • Distinguishes an open circuit from an energized load through the documented minimum-current threshold.
  • Adds de-energized short detection for DC trip circuits when the approved secondary supply is wired to the ETP.
  • The supervised output works with the dedicated 9667-910F termination hardware and its approved cable interface.
  • A regulated 5.00 VDC ±0.25 VDC auxiliary source is required when the installation needs the extended Off-state shorted-load diagnostic.
  • Secondary-power wiring remains separate from the main 48 VDC load supply and must follow the documented commoned-output arrangement.
  • Continuous loopback detects missing field power, a blown fuse and an open or disconnected load during normal operation.
  • The module reports a field short that energizes a load incorrectly and adds Off-state short detection when the auxiliary source is present.
  • POINT, PWR and LOAD indicators distinguish external-circuit faults from the internal PASS, FAULT and ACTIVE diagnostics.
  • The eight commoned outputs operate from 36–72 VDC and switch resistive loads up to 150 W.
  • Each point supports 1 A continuously and allows a 5 A surge for 10 milliseconds.
  • A 100 mA minimum load and 4 mA maximum leakage define the supported range for dependable supervision.
Description
Triconex 3617E provides eight commoned 48 VDC supervised outputs over a 36–72 VDC field range. Its TMR architecture receives three processor commands and passes the voted result through a quadruplicated mechanical-relay output switch.

Continuous voltage and current feedback extends diagnostics beyond the module to the field circuit and connected device. With the optional 5.00 VDC ±0.25 VDC secondary supply, the circuit can detect a shorted load even when the output is commanded off.

The module is rated for 1 A per point and 150 W resistive switching, with a 100 mA minimum connected load and a 1.25 A fast-acting fuse at each output. A separate external termination panel and cable interface are required for installation.
Alternative Names
3617E Triconex 3617E Invensys Triconex 3617E 3617 E Triconex Model 3617E Triconex 3617E Supervised Digital Output Module Triconex 3617E 8-Point SDO Module
Technical notes
For 3617E, off-state shorted-load detection depends on the optional 5.00 VDC ±0.25 VDC secondary supply and the specified ETP wiring.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What diagnostic benefit does secondary power give 3617E?
The 5 V secondary source lets the DC module detect a shorted field load even while the commanded output is Off.
How does the 100 mA rule affect 3617E load selection?
Connected load current must meet the documented minimum so open-load supervision can operate as intended.
Which 48 VDC duties suit 3617E?
It is intended for critical supervised trip, solenoid and relay circuits needing TMR control and field-fault detection.
How is tested 3617E supply described in an offer?
The quotation confirms exact model, revision, condition, test documentation, ETP compatibility, quantity and shipping terms.
Why is a standard 48 VDC DO not equivalent to 3617E?
The supervised relay architecture, minimum-load rule, secondary source, loopback diagnostics and ETP differ from a standard output.
What wiring package supports a 3617E review?
Send the main and secondary supply details, load resistance, inrush, ETP and cable numbers, fuse, point list and proof-test requirement.