Features:
- 1 GB onboard DDR ECC memory
- IEEE ejector handles
- Two PMC-X sites and dual Gigabit Ethernet
The MVME6100-0173 suffix identifies the 1 GB configuration fitted with IEEE ejector handles in the official order table.
Its MV64360 controller links the MPC7457 processor to memory and PCI resources, while the Tsi148 provides the high-speed VME data path.
Do not treat MVME6100-0173 as mechanically identical to the Scanbe-handle option; review the enclosure, backplane, cooling, cabling, and installed mezzanine cards.
The Motorola MVME6100-0173 VMEbus Single-Board Computer is recorded as Active / Available from OEM, with sourcing review available from Apter Power.
Motorola MVME6100-0173 VMEbus Single-Board Computer Manuals, Datasheets, Links
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Motorola MVME6100-0173 VMEbus Single-Board Computer Specs
General
- ManufacturerMotorola
- ModelMVME6100-0173
- ConditionNew and Original
- Product FamilyMVME6100 Series
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Board-level data flow
- Processor complex: A 1.267 GHz MPC7457 combines PowerPC processing with a 128-bit AltiVec execution unit.
- Host bridge: The MV64360 connects processor, DDR266 ECC memory, Ethernet, and PCI resources.
- VME interface: The Tsi148 supplies VME64 compatibility and 2eSST transfer capability.
- Persistent storage: Two 64 MB flash banks and 32 KB NVRAM support boot and retained board information.
Mezzanine expansion conditions
- Site count: MVME6100-0173 provides two PMC-X positions for supported mezzanine functions.
- Bus width: Each documented site supports a 64-bit local interface.
- Operating rates: Module and voltage conditions determine 33, 66, or 100 MHz operation.
- Selection checks: Confirm VIO keying, rear I/O, card width, power, cooling, and application compatibility before fitting a PMC.
Pre-start validation
- Order code: Retain the complete MVME6100-0173 code to preserve the 1 GB and IEEE-handle configuration.
- Backplane: Verify slot selection, P1 and P2 engagement, system-controller settings, and supported VME transfer modes.
- Airflow: Provide forced-air cooling appropriate for the documented 0°C to +55°C operating range.
- Startup review: Check console access, switches, firmware image, Ethernet routing, and installed PMC-X hardware before service.