Features:
- Provides a 5.7-inch monochrome STN operator display.
- Uses 320 × 240 pixels with sixteen display gradations.
- Omits the built-in Ethernet port and uses the documented serial interfaces.
The current ordering configuration is
NS5-MQ00-V2, the NS5-V2 5.7-inch Monochrome Programmable Terminal documented for NS Series.
In the intended system role, its 320 × 240 display supports sixteen gradations, a resistive matrix touch panel and 20 MB of screen-data capacity. A memory card can be used for supported transfer and maintenance functions.
For selection and commissioning, confirm panel cutout, supply, serial host interface, project version and CX-Designer compatibility before replacement. Back up the HMI project and recipe data before removing the installed terminal.
Availability is subject to Apter Power inventory and sourcing confirmation.
Verified resources for Omron NS5-MQ00-V2:
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Provides local operator screens for a PLC-controlled production machine, for its documented operating duty.
- Displays alarms, values and operating commands through a resistive touch interface, through the intended receiving-system interface.
- Supports retrofit of installed NS5-V2 monochrome projects that do not require onboard Ethernet, in the configured and commissioned installation.
- The MQ00 version is explicitly supplied without a built-in Ethernet port, within the configured host communication path.
- Serial host communications depend on the selected PLC link and project setup, using the documented wiring and interface conditions.
- Memory-card support assists project transfer and service operations, before live data exchange is enabled.
- CX-Designer is used to create and transfer supported NS screen projects, through the documented engineering or controller workflow.
- The terminal stores up to 20 MB of screen data for the documented model generation, for the installed channel or external device.
- Project communication settings must match the connected controller before startup, before the restored configuration is returned to service.
- Project and system versions must be checked before restoring a backup to replacement hardware, before a saved project is restored to the terminal.
- Only Omron-supported update procedures should be used for the terminal generation, using the procedure approved for the installed generation.
- A validated backup is retained before any system-program or screen-data change, so recovery remains possible if validation fails.