Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports MXQ8L-40 supply through load, overhang, mounting and stopping verification.

MXQ8L-40

/ 4.9
1001 reviews | Need a Specific Revision?
SMC MXQ8L-40 is a symmetric MXQ air slide table with 8 mm bore and 40 mm stroke for compact guided linear motion.
In Stock
Ships by Wednesday, September 30
Fast Shipping Available
Get a quick price for MXQ8L-40
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for MXQ8L-40

  • Manufacturer:
    SMC
  • Part Number:
    MXQ8L-40
  • Product Family:
    SMC
  • Product Type:
    MXQ8L Symmetric Air Slide Table, 40 mm Stroke
  • Stock:
    1
  • Series:
    MXQ
  • Layout:
    Symmetric type
  • Bore:
    8 mm
  • Stroke:
    40 mm
  • Guide:
    Recirculating linear guide
  • Operating Fluid:
    Air
  • Operating Pressure:
    0.15 to 0.7 MPa
  • Operating Temperature:
    -10 to 60 °C
  • Weight:
    0.25 kg
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Load Selection Mounting Setup Motion Checks Applications

Features:

  • Integrated guided motion: The table and pneumatic drive share a compact MXQ assembly.
  • Symmetric layout: MXQ8L identifies the mirrored port and body arrangement for the 8 mm size.
  • Forty-millimeter travel: Stroke is fixed by the complete model and must match machine clearance.
MXQ8L-40 is a guided air slide table rather than an unguided compact cylinder.

Selection uses combined load factors for mass, static moment and dynamic moment at the real overhang.

Mounting bolts, external alignment and stopping impact must be controlled to protect the guide.

Apter Power can help confirm the SMC MXQ8L-40 MXQ8L Symmetric Air Slide Table, 40 mm Stroke and the documented application details before quotation.
SMC MXQ8L-40 MXQ8L Symmetric Air Slide Table, 40 mm Stroke Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Mass: Include the fixture, fasteners and workpiece in the moving load.
  • Overhang: Measure the actual center of gravity from the table reference surfaces.
  • Moments: Combine pitch, yaw and roll effects according to the catalog method.
  • Speed: Use the intended average and collision speeds in the selection check.
  • Flatness: Mount on a surface that does not twist the integrated guide.
  • Bolt depth: Follow the drawing because long bolts can contact the guide block.
  • Alignment: Avoid forcing external tooling to compensate for machine misalignment.
  • Clearance: Verify the full 40 mm stroke and any adjuster projection.
  • Speed control: Adjust pneumatic flow to prevent excessive end impact.
  • Free travel: Check motion without the load before diagnosing internal binding.
  • Leak isolation: Separate valve, tubing and cylinder leakage during troubleshooting.
  • Switch position: Re-prove optional end detection after mechanical adjustment.
  • Precision transfer: Moves small fixtures on an integrated guided table.
  • Pick-and-place axis: Provides compact linear travel where load factors are verified.
  • Conveyor positioning: Shifts a pallet stop or locator through a defined 40 mm stroke.
  • Exact replacement: Restores a documented symmetric MXQ8L-40 installation.
Description
Guided linear motion is packaged with the pneumatic drive in MXQ8L-40, using the symmetric MXQ8L body arrangement. The integrated table provides a defined moving platform where an unguided cylinder would require separate guidance.

The 40 mm travel of MXQ8L-40 sets the available stroke while the 8 mm size defines the catalog load and moment envelope, a relationship that matters because a fixture can fit the table yet place its center of gravity outside the permitted operating condition.

Machine integration for MXQ8L-40 should control mounting alignment, bolt depth and end-of-stroke energy. Respecting those boundaries helps the recirculating guide move freely and keeps compact installation from becoming a source of binding or impact.
Alternative Names
MXQ8L40
Technical notes
Select MXQ8L-40 from the real load mass, mounting orientation, overhang, average speed and end-stop arrangement. Set speed to limit impact, then confirm the table moves freely through 40 mm without external misalignment. Use the catalog mounting depths; an overlong bolt can contact the guide block and cause malfunction.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
MXQ8L-40 has adequate thrust but the table deflects under the fixture. What should be recalculated?
Recalculate overhang and combined static and dynamic moments using the complete moving mass; thrust alone is not the selection limit.
An MXQ8L-40 binds immediately after installation. Which mounting conditions come first?
Check base flatness, external alignment and whether any mounting bolt exceeds the catalog thread depth.
Can standard MXQ8-40 replace MXQ8L-40 when bore and stroke match?
Do not assume so. MXQ8L is the symmetric layout; compare port positions, envelope, mounting and attached options.
MXQ8L-40 strikes the end position sharply with the production load. What should commissioning adjust?
Reduce speed and verify the selected stopping or adjuster arrangement against moving mass and collision energy.
A loaded MXQ8L-40 moves slowly in only one direction. How should maintenance isolate the cause?
Separate valve flow, tubing restriction, external misalignment and leakage before treating the slide table as the failed component.
An older MXQ8L-40 has an unknown stop and switch arrangement. Can the base model alone define the replacement?
No. Record the full suffix, adjuster, switch, mounting and load arrangement before ordering or installing the spare.

Product Browsing History