Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 6ES7193-1FL50-0XA0

All in stock · Add one and it is quoted together with the model, one shipping cost.

6ES7193-1FL50-0XA0

Siemens 6ES7193-1FL50-0XA0 is a 32-channel ET 200L add-on terminal that extends the station with spring-type field-wiring connections.

In Stock Ships by Tuesday, November 24 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 6ES7193-1FL50-0XA0

6ES7193-1FL50-0XA0Siemens ET 200L 32-Channel Single-Tier Spring-Terminal Add-On
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
Siemens
Part Number
6ES7193-1FL50-0XA0
Product Family
Siemens Simatic DP
Product Type
ET 200L 32-Channel Single-Tier Spring-Terminal Add-On
Stock
1
Weight
0.2998 lbs (0.136 kg)
Tariff Code
85369090
Country of origin
Germany
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Adds 32 spring-type field terminals to a SIMATIC ET 200L station.
  • Organizes the connection points in one terminal tier.
  • Extends field wiring without performing signal processing inside the terminal assembly.
The add-on terminal converts the station channel map into individual spring-clamp landing points.

Each physical connection must remain aligned with its ET 200L electronic channel and common-path assignment.

The terminal body therefore serves as the wiring boundary between field cables and the station electronics.

The Siemens 6ES7193-1FL50-0XA0 ET 200L 32-Channel Single-Tier Spring-Terminal Add-On may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7193-1FL50-0XA0 ET 200L 32-Channel Single-Tier Spring-Terminal Add-On Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Aligning 32 terminals with station channels

  • Numbering: Each spring terminal is identified against one of the 32 channel positions.
  • Controller record: The physical number must match the channel address used in the ET 200L configuration.
  • Common paths: Any shared supply or return assignment is checked separately from channel numbering.
  • Transfer control: Wires are moved one labeled channel at a time when an existing terminal is replaced.

Securing conductors without screw torque

  • Clamp opening: The spring is opened with the documented terminal tool before insertion.
  • Conductor seating: The prepared conductor is inserted fully into its assigned contact.
  • Retention check: A light pull confirms the spring has gripped the conductor.
  • No torque cycle: The connection relies on spring force rather than a screw-tightening value.

Keeping every field landing on one physical level

  • One row depth: All 32 connection points are arranged in a single terminal tier.
  • Label visibility: Channel markings remain readable along the same service plane.
  • Cabinet access: Wiring clearance is planned across the full terminal length.
  • Variant check: A terminal with another tier arrangement is not assumed interchangeable from channel count alone.

Separating the wiring accessory from signal processing

  • Terminal role: The add-on unit only carries field conductors to the station interface.
  • Electronics role: Signal conversion or switching occurs in the matched ET 200L electronic assembly.
  • Fault isolation: Continuity at the terminal is checked before replacing the processing module.
  • Compatibility: The complete 1FL50 suffix must agree with the station hardware and 32-channel mapping.

Description

Siemens 6ES7193-1FL50-0XA0 is a single-tier add-on terminal for a SIMATIC ET 200L station. It provides 32 spring-type connection points that extend the station interface to field conductors.

Each conductor entering 6ES7193-1FL50-0XA0 is retained by its spring clamp and assigned to one channel position. The terminal assembly does not process the signal; it creates the wiring path between the field cable and the matched ET 200L electronics.

The 32-channel organization of 6ES7193-1FL50-0XA0 must be matched to the station terminal map before conductors are transferred. Channel labeling, common connections and the single-tier arrangement are checked together so the physical wiring remains aligned with the controller configuration.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Myrtle
Saudi ArabiaGE Fanuc IC693CPU364

Saudi Buyer Verifies GE IC693CPU364 On-Site

An Saudi project buyer with a China-based office visited three suppliers with an engineer after a previous purchase resulted in poor-quality goods that were not regarded as original. Following an on-site review of GE Fanuc IC693CPU364, IC693CPU372, IC693ALG391 and other stock in Xiamen, the customer selected IC693CPU364, placed an order and planned to test the module first.

3GE models reviewed
Trial OrderTest before wider purchase
“ Seeing the actual GE modules and stock in person gave us confidence to place our first test order. — Hassan ”
Myrtle · Saudi Arabia · October 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study
May
UAEGE IS200VVIBH1C

Evidence Before Delivery

A Dubai power-project customer visited Apter Power in Xiamen to inspect GE turbine-control cards, labels, packaging and visible condition before delivery.

On siteCustomer inspection in Xiamen
Pre-deliveryIdentity & condition reviewed
“ Seeing the products, labels and inspection process in person gave us a clearer understanding of Apter Power's quality control. — Muhammad ”
May · UAE · October 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

Does Siemens 6ES7193-1FL50-0XA0 process the 32 connected signals?

No. Siemens 6ES7193-1FL50-0XA0 is a wiring terminal; the matched ET 200L electronics perform the signal processing.

What should be recorded before moving wires to 6ES7193-1FL50-0XA0?

Record every 6ES7193-1FL50-0XA0 channel number, conductor label and common-path assignment before transferring field wiring.

Do spring terminals on Siemens 6ES7193-1FL50-0XA0 require a tightening torque?

No. Siemens 6ES7193-1FL50-0XA0 uses spring force; use the documented opening tool and verify conductor retention instead of applying screw torque.

Is another 32-channel terminal automatically interchangeable with 6ES7193-1FL50-0XA0?

No. A substitute for 6ES7193-1FL50-0XA0 must also match the ET 200L interface, single-tier layout and terminal mapping.

How can a field wiring fault be separated from an ET 200L module fault at 6ES7193-1FL50-0XA0?

Check conductor seating and continuity through the assigned 6ES7193-1FL50-0XA0 terminal before testing the connected ET 200L electronics.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

6ES7151-7AA11-0AB0
The Siemens 6ES7151-7AA11-0AB0 IM 151-7 CPU interface module runs local control logic in an ET 200S station and exchanges data as an intelligent PROFIBUS DP slave.
In stock
6ES7972-0AC80-0XA0
Siemens 6ES7972-0AC80-0XA0 is a PROFIBUS DP/RS485-IS coupler that converts a standard DP segment into an intrinsically safe bus connection for approved field nodes in hazardous-area systems.
In stock
6ES7151-1AB05-0AB0
The Siemens 6ES7151-1AB05-0AB0 is an ET 200S IM 151-1 FO interface module that connects a modular remote I/O station to PROFIBUS DP over fiber optics.
In stock
6ES7123-1FB00-0AB0
Siemens 6ES7123-1FB00-0AB0 is a SIMATIC SC analog input electronic submodule that converts two ±10 V or 1–5 V field signals into controller data.
In stock
6ES7131-4BD00-0AB0
The Siemens 6ES7131-4BD00-0AB0 SIMATIC ET 200S digital input module converts four 24 V DC field signals into controller process data with input diagnostics.
In stock
6ES7132-4BF00-0AA0
Siemens 6ES7132-4BF00-0AA0 is a 15 mm ET 200S electronic module with eight 24 V DC, 0.5 A outputs, per-channel protection, and isochronous operation.
In stock
6ES7193-1CH10-0XA0
Siemens 6ES7193-1CH10-0XA0 is a SIMATIC ET 200L TB16L terminal block that connects sixteen field channels to an installed electronic block through spring-loaded terminals.
In stock
3RK1922-2BA00
Siemens 3RK1922-2BA00 is a 110 mm ET 200pro rear-panel bus module that connects motor starter isolator modules and the 400 V ASM disconnecting module to the station assembly.
In stock
6ES7972-0BB70-0XA0
Siemens 6ES7972-0BB70-0XA0 is a PROFIBUS RS485 FastConnect bus connector that joins a station to the bus and provides a PG service socket.
In stock
6ES7194-1AA01-0XA0
The Siemens 6ES7194-1AA01-0XA0 connection plug routes PROFIBUS DP and power into an ASM 450 identification-system communication module.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat