Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power supports technical documents, exact-model review, quotations and system configuration guidance.

6ES7136-6DB00-0CA0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7136-6DB00-0CA0 is a 15 mm ET 200SP fail-safe digital output module with four 24 VDC, 2 A channels rated to PL e and SIL 3.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 6ES7136-6DB00-0CA0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7136-6DB00-0CA0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7136-6DB00-0CA0
  • Product Family:
    Siemens Simatic ET 200SP
  • Product Type:
    SIMATIC ET 200SP F-DQ 4x24 VDC/2A PM HF Module
  • Stock:
    1
  • Outputs:
    Four fail-safe transistor channels
  • Current per channel:
    2 A
  • Maximum module current:
    6 A
  • Safety rating:
    PL e / SIL 3
  • Module width:
    15 mm
  • BaseUnit type:
    A0
  • Weight:
    0.059 kg
  • Estimated shipping dimensions:
    7.5x6.9x2.9cm
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Output Channels Safety Ratings Diagnostics & Wiring Product Applications

Features:

  • Four safe outputs: Controls four documented 24 VDC safety-related field circuits.
  • 2 A channels: Supports up to 2 A per output with a 6 A module total.
  • PL e / SIL 3: Provides the documented fail-safe output capability for high-integrity applications.
The module combines output switching and safety diagnostics within a 15 mm ET 200SP position.

BaseUnit type, F-address and safety-project parameters are part of the working configuration.

Field-load current and module-total current must remain within their separate limits.

Apter Power provides official documents and ET 200SP safety-configuration support for 6ES7136-6DB00-0CA0.
Siemens 6ES7136-6DB00-0CA0 SIMATIC ET 200SP F-DQ 4x24 VDC/2A PM HF Module Manuals,Datasheets,Link
Important Notice: Verify the complete catalog number, document revision and installed-system configuration before use.
  • Channel count: Provides four fail-safe transistor outputs.
  • Rated voltage: Controls documented 24 VDC field loads.
  • Channel current: Supports up to 2 A on each output.
  • Module current: Limits the combined output current to 6 A.
  • Performance level: Supports applications up to PL e when correctly engineered.
  • Safety integrity: Supports applications up to SIL 3 when correctly configured.
  • Safety project: F-address and parameterization must agree with the approved program.
  • Proof validation: Any hardware change requires approved safety validation and completion of the documented proof test.
  • Short circuit: Channel diagnostics can indicate a shorted field path.
  • Open circuit: Configured monitoring can identify an interrupted load path.
  • Overload: Module diagnostics report excessive output loading.
  • BaseUnit: The electronic module uses the documented A0 BaseUnit arrangement.
  • Emergency shutdown: Drives documented safe-state actuators in distributed machine systems.
  • Safety interlocking: Controls field devices used in protective interlock functions.
  • Fail-safe valves: Supports 24 VDC solenoids within an engineered safety loop.
Description
In a SIMATIC ET 200SP station, 6ES7136-6DB00-0CA0 switches four fail-safe 24 VDC output circuits for safety-related field devices. Its documented capability supports applications engineered up to PL e and SIL 3.

The output capacity and integrated diagnostics allow 6ES7136-6DB00-0CA0 to control demanding loads while reporting short-circuit, open-circuit and overload conditions. This helps the safety system distinguish a field-path problem from an electronic-module issue.

For emergency shutdown, protective interlocking and safe actuator control, 6ES7136-6DB00-0CA0 provides a compact high-feature output point within ET 200SP. Its value depends on the BaseUnit, F-address and approved safety project operating together as one validated function.
Alternative Names
6ES71366DB000CA0 6ES7 136-6DB00-0CA0 6ES7-136-6DB00-0CA0 6ES7136 6DB00 0CA0 ET 200SP F-DQ 4x24V F-DQ 4x24VDC 2A 136-6DB00-0CA0 Siemens 6DB00
Technical notes
6ES7136-6DB00-0CA0 provides four fail-safe 24 VDC transistor outputs at 2 A per channel and 6 A per module. Preserve the A0 BaseUnit, F-address, safety parameters, load grouping and proof-test evidence. The named successor still requires a controlled safety-hardware and project review before use in the installed system.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should output loading be assessed for 6ES7136-6DB00-0CA0?
Evaluate both the 2 A limit for each channel and the 6 A module total so the connected safety loads remain within both boundaries.
What does a short-circuit or open-circuit diagnostic mean on 6ES7136-6DB00-0CA0?
It directs troubleshooting toward the affected field path and load before the electronic module is treated as the cause.
Which project data is essential before replacing 6ES7136-6DB00-0CA0?
The F-address, safety parameters, load grouping, BaseUnit type and approved proof-test information form the working safety configuration.
Can 6ES7136-6DB00-0CA0 be installed on any ET 200SP BaseUnit?
The electronic module uses the documented A0 BaseUnit arrangement, so the installed BaseUnit and terminal assignment must be suitable.
How should the identified successor be evaluated against 6ES7136-6DB00-0CA0?
The safety project, BaseUnit, channel loading, F-address and validation requirements should be reviewed before the newer article is introduced.
What commissioning step is critical after changing 6ES7136-6DB00-0CA0?
The restored safety function should be validated against the approved project and proof-test procedure before the outputs return to service.

Product Browsing History