    Apter Power provides quotations, manuals, and model-selection support for 6ES7650-1AH61-5XX0.

6ES7650-1AH61-5XX0

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6ES7650-1AH61-5XX0 is a six-channel fail-safe analog input HART marshalled termination assembly for connecting ET 200M module 6ES7336-4GE00-0AB0 with field transmitters.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6ES7650-1AH61-5XX0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7650-1AH61-5XX0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7650-1AH61-5XX0
  • Product Family:
    Siemens Simatic PCS 7 System
  • Product Type:
    PCS 7 6-Channel Fail-Safe Analog Input HART MTA
  • Stock:
    1
  • Input Channels:
    6
  • Associated I/O Module:
    6ES7336-4GE00-0AB0
  • Power Input:
    21.6 to 28.8 V DC
  • Normal Current Consumption:
    0.5 A maximum
  • Maximum Inrush Current:
    9.368 A including transmitter inrush
  • Power Inputs:
    Two removable inputs for single or redundant feed
  • I/O Module Connectors:
    2 for redundant module operation
  • Standard Channel Fuse:
    0.1 A fast-blow
  • Optional Channel Fuse:
    1.5 A fast-blow for four-wire transmitters
  • Module Power Fuse:
    0.5 A
  • Terminal Wire Range:
    24 to 14 AWG; 0.205 to 2.08 mm²
  • Mounting:
    35 mm deep top-hat DIN rail
  • Field Terminals:
    Sensor power, signal positive, signal negative, and shield per channel
  • HART Access:
    Handheld terminal connection per channel
  • Transmitters per Channel:
    1
  • Sensor Supply Protection:
    Current-limited; no external fuse required
  • Ambient Temperature:
    -25 to +60 °C
  • Relative Humidity:
    5% to 95%, non-condensing
  • Maximum Safety Integrity:
    SIL 3 according to IEC 61508
  • Proof-Test Interval:
    20 years
  • Weight:
    1.202 lbs (0.545 kg)
  • Estimated shipping dimensions:
    25.4x13.6x8.6cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Power Path Channel Wiring Redundancy HART Access

Features:

  • Six field-current channels terminate on removable connectors.
  • Two protected power feeds supply the MTA, modules, and field transmitters.
  • Dual module connectors and pluggable diode boards preserve the redundant signal path.
Siemens 6ES7650-1AH61-5XX0 sits between six HART transmitters and the ET 200M fail-safe analog input module.

Its separate field, power, shield, and module connections keep loop wiring distinct from the redundant module path.

Channel and power LEDs expose loss of a feed or an opened fuse before the signal reaches the input module.

The 6ES7650-1AH61-5XX0 article uses the FAIH wiring and fuse arrangement shown in its dedicated manual section; adjacent MTA order numbers use different channel hardware.
Siemens 6ES7650-1AH61-5XX0 PCS 7 6-Channel Fail-Safe Analog Input HART MTA Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Redundant Power Distribution

  • Power feeds: Two removable feeds accept single or redundant 24 V DC supply.
  • ORing: The diode path supplies the assembly from either available feed.
  • Module fuses: Separate 0.5 A fuses protect the two I/O module connectors.
  • Channel feeds: Each transmitter branch is fused and indicated independently.

Field Channel Connections

  • Per channel: Sensor power, signal positive, signal negative, and shield terminals are provided.
  • Transmitter count: One transmitter is connected to each channel.
  • Wire range: Field and power terminals accept the documented 24 to 14 AWG range.
  • Shield: Channel shields terminate at the assembly and can be bonded through the ground stud.

Dual-Module Signal Path

  • Connectors: J1 and J2 serve the two redundant analog input modules.
  • Diode boards: Two pluggable zener boards maintain the remaining signal path during module removal.
  • Nonredundant use: A single module uses the documented J2 connection arrangement.
  • Maintenance: Board and fuse status must be checked before removing one redundant module.

HART and Loop Limits

  • Handheld access: A HART handheld terminal can be connected for each channel.
  • Sensor feed: The assembly supplies a current-limited field-power path.
  • Loop voltage: Two-wire loops must retain the required voltage at the transmitter and barrier.
  • Four-wire option: The documented optional fuse applies only to the specified four-wire arrangement.
Description
Siemens 6ES7650-1AH61-5XX0 is a six-channel fail-safe analog input HART marshalled termination assembly for PCS 7 ET 200M remote I/O. It terminates field transmitter wiring and connects the six current channels to the 6ES7336-4GE00-0AB0 input module.

Power for 6ES7650-1AH61-5XX0 enters through two removable feeds. The board diode-ORs those feeds, then distributes protected power through separate module fuses and individual channel fuses so one field branch can be isolated without removing the shared termination assembly.

For redundant input operation, 6ES7650-1AH61-5XX0 routes each signal through two pluggable zener-diode boards to the two module connectors. Removing one input module for maintenance leaves the remaining path connected, while channel LEDs show whether sensor power and its fuse are present.

Each channel on 6ES7650-1AH61-5XX0 provides sensor power, positive and negative signal terminals, shield termination, and access for a HART handheld terminal. The current-limited sensor feed supports one transmitter per channel and requires the specified cable and voltage-drop check for two-wire loops.
Alternative Names
6ES76501AH615XX0 6ES7650 1AH61 5XX0 6ES 7650 1AH61 5XX0 Siemens 6ES7650-1AH61-5XX0 6ES7650-1AH61-5XX0 FAIH MTA 6ES7650-IAH61-5XX0 6ES7650-1AH6I-5XX0 6E57650-1AH61-5XX0
Technical notes
For Siemens 6ES7650-1AH61-5XX0, verify the selected channel fuse against transmitter wiring because the optional 1.5 A fuse changes the short-circuit maintenance check.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why is one channel LED off on 6ES7650-1AH61-5XX0 while both power LEDs are on?
Check the 6ES7650-1AH61-5XX0 channel fuse, field terminal, transmitter wiring, and channel power path because each field branch is protected independently.
Can 6ES7650-1AH61-5XX0 keep reading when one redundant input module is removed?
Yes, when 6ES7650-1AH61-5XX0 is wired in the documented redundant arrangement, the diode-board path keeps the remaining module connected.
Why does a two-wire transmitter on 6ES7650-1AH61-5XX0 fail at high loop current?
Measure the available loop voltage because 6ES7650-1AH61-5XX0, the barrier, cable, and transmitter must remain within the documented voltage budget.
Which connector is used for nonredundant operation on 6ES7650-1AH61-5XX0?
Install the FAI input cable at J2 for the documented nonredundant 6ES7650-1AH61-5XX0 arrangement.
What should be checked after a 1.5 A channel fuse opens on 6ES7650-1AH61-5XX0?
Test or replace the two zener-diode boards on 6ES7650-1AH61-5XX0 before returning the affected loop to service.
How is a HART handheld connected to 6ES7650-1AH61-5XX0?
Use the dedicated HART access point for the required 6ES7650-1AH61-5XX0 channel while keeping the loop wiring and shield intact.