Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail info@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power can provide 6ES7315-7TJ10-0AB0 manuals, quotations, and technology-CPU selection support.

6ES7315-7TJ10-0AB0

/ 4.9
1001 reviews | Need a Specific Revision?
For coordinated PLC and motion tasks, Siemens 6ES7315-7TJ10-0AB0 combines an S7-300 processor with technology objects, a drive-oriented PROFIBUS DP port, and PROFINET networking.
In Stock
Ships by Saturday, October 17
Fast Shipping Available
Get a quick price for 6ES7315-7TJ10-0AB0
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6ES7315-7TJ10-0AB0

  • Manufacturer:
    Siemens
  • Part Number:
    6ES7315-7TJ10-0AB0
  • Product Family:
    Siemens Simatic S7-300
  • Product Type:
    CPU 315T-3 PN/DP Technology Central Processing Unit
  • Stock:
    1
  • Work Memory:
    384 KB.
  • MMC Requirement:
    8 MB SIMATIC Micro Memory Card.
  • First Interface:
    MPI/PROFIBUS DP, up to 12 Mbit/s.
  • Second Interface:
    PROFIBUS DP drive interface.
  • Third Interface:
    PROFINET with two-port switch.
  • Integrated Technology I/O:
    Present.
  • Engineering Software:
    STEP 7 V5.5 SP2 and S7-Technology V4.2 SP3.
  • Supply Voltage:
    24 V DC; 19.2–28.8 V DC.
  • Current Consumption, Rated:
    1.05 A.
  • Current Consumption, No-Load:
    230 mA typical.
  • Inrush Current:
    6.5 A typical; I²t 1 A²s.
  • Power Loss:
    7.5 W typical.
  • Technology Objects:
    32 total; up to 8 axes.
  • Auxiliary Objects:
    16 output cams, 16 cam tracks, 8 measuring inputs, 8 external encoders.
  • Path Objects:
    Up to 4.
  • Weight:
    1.583 lbs (0.718 kg)
  • Estimated shipping dimensions:
    15.5x13.1x12.8cm
  • Tariff Code:
    85371091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Motion Objects Drive Bus PN Interface Engineering Set

Features:

  • Combines conventional S7-300 PLC execution with integrated technology-object processing.
  • Assigns a dedicated PROFIBUS DP interface to coordinated drive communication.
  • Connects PROFINET devices through an integrated two-port Ethernet switch.
The technology-object pool covers axes, cams, cam tracks, measuring inputs, external encoders, and path control.

An MPI/DP port, a drive-oriented DP port, and a PROFINET interface give the CPU three distinct communication roles.

STEP 7 and S7-Technology configure the processor and its technology functions, with the project stored on an 8 MB MMC.

The Siemens 6ES7315-7TJ10-0AB0 CPU 315T-3 PN/DP Technology Central Processing Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6ES7315-7TJ10-0AB0 CPU 315T-3 PN/DP Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Organizing integrated technology functions

  • Object Pool: The CPU supports a combined pool of 32 technology objects.
  • Axis Limit: Up to eight axis objects can be configured within that pool.
  • Cam Functions: Output cams and cam tracks create position-related switching logic.
  • Measurement: Measuring inputs and external encoders provide event and position information to technology functions.

Separating drive communication

  • Dedicated Interface: The second PROFIBUS DP port is intended for the drive-oriented communication path.
  • Device Assignment: Drive nodes are configured on that bus independently from general MPI/DP devices.
  • Cyclic Exchange: Setpoints and actual values pass between the technology CPU and configured drives through the DP connection.
  • Project Consistency: Bus parameters, drive addresses, and technology objects must match the STEP 7 and S7-Technology project.

Ethernet and PROFINET access

  • Two-Port Switch: The Ethernet interface includes two physical ports for line or local network connections.
  • PROFINET Role: The CPU exchanges cyclic and diagnostic data with configured PROFINET devices.
  • Online Access: Engineering communication can reach the controller through the Ethernet path.
  • Network Separation: PROFINET remains distinct from both MPI/DP and the drive-oriented DP interface.

Software and memory prerequisites

  • STEP 7: CPU hardware configuration requires STEP 7 V5.5 SP2 or a supported later environment.
  • Technology Package: S7-Technology V4.2 SP3 configures the integrated technology objects.
  • Firmware Pair: CPU V3.2 and technology V4.1.5 define the documented function set.
  • Project Medium: The installed configuration is stored on an 8 MB SIMATIC Micro Memory Card.
Description
Siemens 6ES7315-7TJ10-0AB0 is a SIMATIC S7-300 CPU 315T-3 PN/DP that combines conventional PLC execution with integrated technology functions. It manages the control program and the configured motion-related objects from one technology CPU.

Axes, output cams, cam tracks, measuring inputs, external encoders, and path objects share the technology-object framework of 6ES7315-7TJ10-0AB0. Their configured relationships determine how motion events and position information are processed rather than treating each function as an unrelated channel specification.

Engineering 6ES7315-7TJ10-0AB0 joins the hardware configuration with the S7-Technology project and stores the resulting configuration on the required SIMATIC Micro Memory Card. Integrated technology I/O then supplies time-critical external signals directly to the corresponding technology functions.

Network duties are deliberately separated on 6ES7315-7TJ10-0AB0: the first interface supports MPI or general PROFIBUS DP traffic, the second PROFIBUS connection is assigned to drives, and the PROFINET interface uses an integrated two-port switch. This keeps drive exchange, engineering access, and Ethernet communication on defined paths.
Alternative Names
6ES73157TJ100AB0 6ES7 315-7TJ10-0AB0 6ES7 315 7TJ10 0AB0 Siemens 6ES7315-7TJ10-0AB0 CPU 315T-3 PN/DP 6ES7315-7TJ10-0AB0 6ES7315-7TJ10-OABO 6ES73I5-7TJ10-0AB0 Siemens 6ES73157TJ100AB0
Technical notes
Integrated technology objects share one controller with separate MPI/DP, drive-DP, and PROFINET routes in Siemens 6ES7315-7TJ10-0AB0.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Why does 6ES7315-7TJ10-0AB0 separate the drive bus from its first MPI/DP interface?
6ES7315-7TJ10-0AB0 reserves the second DP interface for drive communication, leaving the first port available for MPI or general PROFIBUS DP traffic.
Which memory card must be present before a 6ES7315-7TJ10-0AB0 project can be loaded?
The configured project for 6ES7315-7TJ10-0AB0 requires an 8 MB SIMATIC Micro Memory Card.
How should the technology-object limit of 6ES7315-7TJ10-0AB0 be interpreted when axes and cams are combined?
6ES7315-7TJ10-0AB0 supports 32 technology objects in total, so configured axes, cams, measuring inputs, and other objects share that pool.
What engineering packages are needed to change motion functions in 6ES7315-7TJ10-0AB0?
Configure 6ES7315-7TJ10-0AB0 with STEP 7 V5.5 SP2 and S7-Technology V4.2 SP3 or supported later environments.
When should the PROFINET ports of 6ES7315-7TJ10-0AB0 be used instead of the DP drive interface?
Use the PROFINET switch of 6ES7315-7TJ10-0AB0 for Ethernet-based devices and online access; keep the second DP port for configured drives.
Where do time-critical measurement signals enter the technology functions of 6ES7315-7TJ10-0AB0?
The integrated technology I/O of 6ES7315-7TJ10-0AB0 accepts the defined measurement and encoder signals for its technology objects.

Product Browsing History