6DP1210-8CA

/ 4.9
1001 reviews | Need a Specific Revision?
Siemens 6DP1210-8CA operates as a TELEPERM XP FUM210 sensor conditioning module that acquires binary field states and sends monitored output commands.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 6DP1210-8CA
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 6DP1210-8CA

  • Manufacturer:
    Siemens
  • Part Number:
    6DP1210-8CA
  • Product Family:
    Siemens Teleperm
  • Product Type:
    TELEPERM XP FUM210 Sensor Conditioning Module
  • Stock:
    1
  • Changeover Contacts:
    14 with sensor supply and monitoring
  • Single Contacts:
    28 with sensor supply and monitoring
  • Binary Inputs:
    28 without sensor supply
  • Binary Outputs:
    16
  • Motor Control Capacity:
    5/8 motors
  • Solenoid Valve Control:
    5/8 solenoid valves
  • Actuator Control:
    4/5 actuators
  • Step Controller Support:
    3/4 step controllers
  • Reversing Actuator Support:
    2/3 reversing actuators
  • Redundant Use:
    Supported
  • Group Alarm Output:
    Supported
  • Weight:
    0.8818 lbs (0.4 kg)
  • Estimated shipping dimensions:
    2x26.4x26.3cm
  • Tariff Code:
    85389091
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Contact Conditioning Binary Inputs Output Control Monitoring Paths

Features:

  • Monitored contact modes accept fourteen changeover or twenty-eight single contacts.
  • A separate arrangement acquires twenty-eight binary inputs without sensor supply.
  • Sixteen binary outputs carry control or signaling commands away from the module.
The FUM210 conditions field-contact states before the TELEPERM XP control path uses them.

Sensor-supplied and unsupplied input arrangements require different terminal planning even when both deliver binary states.

Output commands remain separate from the monitored input circuits so cabinet wiring must preserve their assigned channel roles.

The Siemens 6DP1210-8CA TELEPERM XP FUM210 Module may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 6DP1210-8CA TELEPERM XP FUM210 Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Organizing supplied and monitored contact circuits

  • Changeover mode: Fourteen changeover contacts use sensor supply and monitoring.
  • Single-contact mode: Twenty-eight single contacts can use the same supplied and supervised structure.
  • Circuit supervision: Monitoring distinguishes the field-contact circuit from an ordinary unsupplied input.
  • Terminal match: The selected contact arrangement must agree with the physical channel wiring.

Acquiring unsupplied field states

  • Input capacity: The module can receive twenty-eight binary inputs without sensor supply.
  • Signal role: These channels transfer field states into the TELEPERM XP processing path.
  • Mode distinction: Unsupplied inputs are not wired as monitored sensor-supply circuits.
  • Cabinet check: Each conductor must terminate on the channel group defined for the chosen mode.

Passing binary commands to connected circuits

  • Output count: Sixteen binary outputs provide the command side of the module.
  • Control path: Processed TELEPERM XP decisions become field-facing binary commands.
  • Signal separation: Output wiring remains distinct from the contact-acquisition terminals.
  • Load boundary: The connected circuit must follow the documented FUM210 output arrangement.

Relating field status to supervision

  • Contact state: The input path identifies whether the field contact is open or closed.
  • Supply supervision: Monitored modes also evaluate the supplied contact circuit.
  • System signaling: Conditioned results can be used by TELEPERM XP monitoring and signaling functions.
  • Fault tracing: A wiring fault should be separated from a valid process-state change before output logic is examined.
Description
In a TELEPERM XP signal cabinet, Siemens 6DP1210-8CA functions as a FUM210 sensor conditioning module that collects binary field states and produces commands for control, monitoring and signaling.

For monitored field contacts, 6DP1210-8CA can organize fourteen changeover contacts or twenty-eight single contacts with sensor supply and supervision. This arrangement lets the module evaluate both the commanded contact state and the integrity of the supplied input circuit.

A separate acquisition arrangement allows 6DP1210-8CA to receive twenty-eight binary inputs without sensor supply. Those input states remain distinct from the sixteen binary outputs that pass commands toward connected control or signaling circuits.

Inside the TELEPERM XP signal chain, 6DP1210-8CA therefore links field-contact acquisition with output control on one FUM210 assembly. Terminal assignment and the selected contact mode must agree with the cabinet wiring before the channel groups are commissioned.
Alternative Names
6DP12108CA 6DP1210 8CA 6DP 1210-8CA Siemens 6DP12108CA FUM210 6DP1210-8CA TELEPERM XP 6DP1210-8CA 6DP121O-8CA 6DP1210-BCA
Technical notes
Contact states entering Siemens 6DP1210-8CA are conditioned separately from the sixteen binary command outputs used by the TELEPERM XP control path.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How should changeover contacts be assigned on 6DP1210-8CA?
Use the monitored contact arrangement documented for fourteen changeover circuits on 6DP1210-8CA. Verify both sides of each changeover contact and the sensor-supply path before interpreting its state in TELEPERM XP.
Why does 6DP1210-8CA distinguish supplied contacts from ordinary binary inputs?
The monitored modes of 6DP1210-8CA evaluate a sensor-supplied contact circuit, while the separate twenty-eight-input arrangement accepts binary states without that supply. Their terminal and diagnostic behavior are therefore not interchangeable.
Which channels on 6DP1210-8CA send commands back to the field?
The sixteen binary outputs of 6DP1210-8CA form the command side of the FUM210 assembly. Keep those conductors separate from the contact-acquisition groups when tracing cabinet wiring.
A contact state is implausible on 6DP1210-8CA; what should be checked first?
Confirm whether 6DP1210-8CA is wired for changeover, single-contact or unsupplied binary-input operation. Then compare the sensor-supply and monitoring connections with the chosen channel arrangement.
Can all twenty-eight input paths and monitored contact modes on 6DP1210-8CA be treated as the same circuit?
No. Siemens 6DP1210-8CA documents different organizations for monitored supplied contacts and unsupplied binary inputs. Use the terminal plan for the selected mode instead of assuming identical channel wiring.
What identifies the correct FUM210 hardware when replacing 6DP1210-8CA?
Match the complete 6DP1210-8CA order number and confirm the required input-contact and output organization. The FUM210 designation alone can describe a function family without preserving this exact suffix.