Yokogawa NFTR8S-10 S2 is a 12-channel pressure clamp terminal block that connects field RTD wiring to the NFAR181 analog RTD input module, with a surge absorber for added protection in industrial temperature measurement systems.
In Stock
Ships by Thursday, October 29
Fast Shipping Available
Get a quick price for NFTR8S-10 S2
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for NFTR8S-10 S2

  • Manufacturer:
    Yokogawa
  • Part Number:
    NFTR8S-10 S2
  • Product Family:
    Centum CS-Centum VP
  • Product Type:
    Pressure Clamp Terminal Block
  • Stock:
    1
  • Application:
    Analog RTD
  • Connecting Channels:
    12
  • Connecting Module Name:
    NFAR181
  • Suffix Codes:
    1=With surge absorber; 0=Always 0
  • Bare wire diameter:
    0.5–2.0 mm² (AWG 20–14)
  • Bare wire stripping depth:
    11 mm
  • Weight:
    0.2 kg
  • Estimated shipping dimensions:
    3.2x6x11.3cm
  • Tariff Code:
    8538900000
  • Country of origin:
    Japan
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Specifications Installation Connection Application Scenarios

Features:

  • Provides a centralized field wiring interface for up to 12 analog RTD measurement channels.
  • Supports 0.5–2.0 mm² bare conductors, equivalent to AWG 20–14, with an 11 mm stripping depth for terminal connection.
  • The -10 suffix identifies the version equipped with a surge absorber for industrial RTD wiring applications.
Accurate temperature monitoring is important in oil, chemical, power, and other process industries where operating conditions must be observed continuously. Yokogawa NFTR8S-10 S2 provides the physical connection interface for bringing multiple field RTD circuits into the control architecture. With capacity for 12 channels, the terminal block helps consolidate sensor wiring before signals enter the associated input hardware. Pressure clamp connections support practical installation of field conductors without changing the fundamental RTD measurement arrangement.

Rather than performing temperature measurement independently, NFTR8S-10 S2 works alongside the NFAR181 analog RTD input module. RTD sensor cables from field equipment terminate at the pressure clamp connections, while NFAR181 handles the corresponding input channels. Temperature information can subsequently pass to system-level processing hardware such as FCN-500. Such an arrangement supports centralized observation of process temperatures from a DCS or control-room environment.

Industrial temperature systems often involve numerous sensors distributed across equipment and process areas, making structured field connections important for installation and maintenance. Yokogawa NFTR8S-10 S2 accepts bare conductors from 0.5 to 2.0 mm², or AWG 20 to 14, and requires an 11 mm stripping depth. The -10 suffix configuration incorporates a surge absorber, while the second suffix position remains fixed at 0. Combined with NFAR181 and the appropriate control hardware, the terminal block forms part of the signal path linking field RTDs with centralized temperature monitoring.

The NFTR8S-10 S2 Yokogawa Pressure Clamp Terminal Block may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
Yokogawa NFTR8S-10 S2 Pressure Clamp Terminal Block Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Yokogawa NFTR8S-10 S2 Pressure Clamp Terminal Block Specs

General

  • Manufacturer Yokogawa
  • Model NFTR8S-10 S2
  • Condition New Original ready stock
  • Product Family NFTI3S-00 S2,NFTB5S-00 S2,NFTA4S-00 S2
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Rail Mounting: Snap directly into the 35mm standard DIN rail inside the control cabinet.
  • Position Fixing: Use side limiters to prevent the terminal block from sliding left or right on the rail.
  • Module Interlocking: Interlock it with the NFAR181 module using a dedicated signal cable.
  • Error-Proofing Coding: Check the error-proofing pins on the back to ensure they match the target I/O module model.
  • Wire Stripping: Precisely strip 11mm of insulation from 0.5-2.0 mm² field RTD signal wires.
  • Crimping Operation: Use a dedicated tool to press down the spring clips and insert the bare wire directly.
  • Shielding and Grounding: Connect the shielding layer of the RTD cable to the dedicated grounding copper busbar.
  • Surge Detection: Confirm that the built-in surge absorber grounding wire is correctly connected to the system low-resistance ground.
  • Industrial Furnaces: Used for high-density temperature data acquisition using multi-point resistance temperature detectors (RTD) sensors.
  • Hazardous Chemical Storage Tanks: Utilizes built-in surge protection to block lightning strikes or external high-power electrical surges.
  • High-Vibration Sites: Utilizes a screwless pressure spring clip structure to prevent wiring loosening due to prolonged vibration.
  • Compact Control Cabinets: Quickly achieve modular switching of 12-channel signals within limited space.
Description
Yokogawa NFTR8S-10 S2 provides the field wiring interface for analog RTD measurement applications using the NFAR181 input module. The terminal block accommodates 12 RTD channels, allowing multiple temperature sensor circuits to be organized at a common connection point. Pressure clamp terminals accept bare wire from 0.5 to 2.0 mm², corresponding to AWG 20 to 14, with an 11 mm wire stripping depth specified for connection.

In a complete temperature monitoring arrangement, Yokogawa NFTR8S-10 S2 receives wiring directly from as many as 12 field RTD sensors. The terminal block works together with the NFAR181 12-channel RTD input module, which handles the connected temperature signals before system-level processing. Information can then be transferred through the control architecture to a CPU such as FCN-500 for monitoring and display in a DCS or central control environment.

Yokogawa NFTR8S-10 S2 cannot operate as an independent temperature input device because the terminal block serves as the connection interface rather than the signal-processing or control component. The -10 suffix configuration identifies the version with a surge absorber, while the second suffix digit remains 0. In oil, chemical, power, and other industrial facilities, the arrangement provides a practical connection path from field RTD wiring through the NFAR181 input module to the control system.
Alternative Names
NFTR8S-I0 S2 NFTR8S-1O S2 NFTR8S10 S2 NFTI3S-00 S2 NFTB5S-00 S2 NFTA4S-00 S2 NFPW442-10 S2 NFLR121-S00 S1
Technical notes
The Yokogawa NFTR8S-10 S2 is a heavy-duty pressure clamp terminal block designed for reliable signal termination, featuring 8 dual-channel positions to streamline connection paths in ProSafe-RS environments.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What role does Yokogawa NFTR8S-10 S2 perform in an RTD measurement system?
Yokogawa NFTR8S-10 S2 provides the pressure clamp connection point between field RTD sensor wiring and the NFAR181 analog RTD input module, supporting 12 temperature measurement channels.
Why does NFTR8S-10 S2 need an NFAR181 module?
NFTR8S-10 S2 functions as a terminal block rather than a standalone input module. NFAR181 provides the input-module function required to handle RTD signals before temperature information reaches the control system.
How many RTD channels can NFTR8S-10 S2 connect?
NFTR8S-10 S2 supports 12 channels, matching the 12-channel analog RTD application of the NFAR181 input module.
Does NFTR8S-10 S2 include surge protection?
Yes. The suffix code 1 identifies a configuration with a surge absorber, while the following suffix code 0 is fixed.