3500 System
Bently Nevada
Contact Us

3500 System

Technical Resources For Bently nevada

Browse 3500 System

Browse available series in our catalog of 3500 System products.
  • 133300-01
    133300-01
    The Bently Nevada 133300-01 is a half-height Legacy Low Voltage DC Power Input Module for 3500 systems, accepting 20–30 Vdc input and mounting directly behind the power supply to provide filtered.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 3500/01-01
    3500/01-01
    The Bently Nevada 3500/01-01 is a specialized engineering software and documentation package designed to program, manage, and scale the Bently Nevada 3500 Series Machinery Protection System.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 136719-01
    136719-01
    The Bently Nevada 136719-01 is a critical, dedicated Internal Barrier Earthing I/O Module engineered to provide a robust, intrinsically safe (IS) earth connection directly through the 3500 Machinery Protection System backplane.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 3500/05-02-05-00-00-00
    3500/05-02-05-00-00-00
    The Bently Nevada 3500/05-02-05-00-00-00 is a 12-inch, seven-slot 3500 System Rack with the rack-mount option for compact machinery-protection installations.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 147663-01
    147663-01
    Bently Nevada 147663-01 is the I/O module for the legacy 3500/94 VGA Display Monitor, providing VGA display and RS232 touch-data connections for that generation.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 128275-01F
    128275-01F
    Bently Nevada 128275-01F is an original filler plate (blank module) that occupies unused 3500 rack slots, ensuring proper airflow and physical integrity while reserving space for future expansion.
    Manufacturer: Bently Nevada
    /4.9
  • 3500/50M 288062-02
    3500/50M 288062-02
    The 3500/50M 288062-02 is a Bently Nevada 2‑channel tachometer module for proximity probes or magnetic pickups, measuring shaft speed, rotor acceleration, and direction with programmable alarms.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 3500/05-02-04-01-00-00
    3500/05-02-04-01-00-00
    The Bently Nevada 3500/05-02-04-01-00-00 is a specialized 3500 System Mini-Rack configured explicitly with a 12-inch frame size containing seven available module slots.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 3500/42E 285691-01
    3500/42E 285691-01
    Bently Nevada 3500/42E 285691-01 is the Proximitor/Seismic monitor for the 3500 ENCORE platform, supporting proximity and seismic transducer inputs for machinery protection.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 172115-01
    172115-01
    Bently Nevada 172115-01 is a external termination block designed exclusively for the 3500/65 16-channel temperature monitor, enabling reliable RTD and isolated tip thermocouple signal termination in mission-critical rotating machinery protection systems.
    Manufacturer: Bently Nevada
    /4.9
  • 172109-01
    172109-01
    Bently Nevada 172109-01 is the 3500/65 RTD/isolated-tip thermocouple I/O module with external terminations for temperature monitoring systems.
    Manufacturer: Bently Nevada
    /4.9
    In Stock
  • 3500/32-01-01
    3500/32-01-01
    The Bently Nevada 3500/32-01-01 is a full-height, 4-channel relay module designed for the 3500 monitoring system, providing four independently programmable SPDT relay outputs for critical machinery protection.
    Manufacturer: Bently Nevada
    /4.9
1 2 3 4 5 6 7 8 9 10 ... 14

Support Machinery Protection with Bently Nevada 3500 System Parts

Reliable machinery monitoring depends on correctly configured racks, interface modules, and supporting hardware. Bently Nevada 3500 System parts help industrial teams maintain machinery protection installations used with critical rotating equipment. This collection includes rack hardware, display-related I/O components, filler plates, and other model-specific parts for scheduled maintenance, system expansion, and component replacement. Buyers should compare the complete part number, option codes, rack configuration, and technical documentation to select suitable components for the installed monitoring system.

Key Bently Nevada 3500 System Components

Each 3500 System component serves a specific mechanical, monitoring, or interface function. Reviewing the rack layout and required application can help maintenance teams identify an appropriate replacement.

  • 3500/05-02-05-00-00-00 provides a compact seven-slot mini-rack chassis designed for machinery protection installations with limited mounting space. It supplies the physical framework needed to organize compatible Bently Nevada 3500 System modules while supporting continuous monitoring of important rotating assets. Buyers should confirm the rack size, mounting arrangement, power supply requirements, and complete option code against the existing installation.
  • 147663-01 serves as a dedicated I/O module for the Bently Nevada 3500/94 VGA Display system. It supports video and touch-interface connectivity between the machinery protection rack and a compatible industrial VGA monitor, helping operators access system information through a local display. Confirm the display model, cable connections, rack configuration, and revision requirements prior to replacement.
  • 128275-01F functions as a blank filler plate for unused Bently Nevada 3500 rack positions. Filling open slots helps maintain the rack's intended physical arrangement and airflow while keeping space available for later system expansion. This component can also help protect unused positions from dust and accidental contact, subject to installation according to the applicable rack documentation.

Your needs, our focus

Our experienced service team accurately understands product requirements and service needs, promptly fulfilling all your requests without delay

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How can I confirm compatibility with my Bently Nevada 3500 System?
Compare the full part number and every option code with the component being replaced. Check the rack size, slot position, module type, firmware or hardware revision, connector arrangement, and associated monitoring equipment. Parts with similar appearances may perform different functions, so use the applicable Bently Nevada documentation and equipment records for confirmation.
What information should I provide when requesting a quote?
Provide the complete part number, required quantity, destination country, and any known revision or configuration details. A clear photograph of the existing product label may help confirm option codes and reduce identification errors. For rack components, include the rack size and mounting arrangement when available.
Why should unused positions in a 3500 rack have filler plates?
A suitable filler plate closes an unused rack position and helps preserve the intended physical layout. It can support proper airflow management, reduce exposure to dust, and limit accidental contact with the open slot. It also allows the position to remain reserved for a compatible module that may be installed during a future expansion.
Can individual 3500 System parts be replaced without changing the complete rack?
Many maintenance projects involve replacing a specific rack component rather than the entire monitoring system. The correct approach depends on the failed component, installed configuration, and site procedures. Qualified personnel should verify compatibility, record the current setup, follow required isolation procedures, and test the machinery protection functions after replacement.
Who should install Bently Nevada machinery protection components?
Installation should be completed by trained instrumentation or machinery protection personnel. Technicians should follow site safety rules and the applicable manufacturer documentation, control electrostatic discharge, inspect connectors, and confirm module placement. Configuration and functional checks should be completed before monitored equipment returns to normal service.