Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued

    Discontinued date: 2022-12-31

    Replacement category: Engineering Replacement

    Engineering replacement: 2198-C1007-ERS

2093-AMP5

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2093-AMP5 is a Kinetix 2000 230 V Axis Module with 3.0 A rms continuous current and 0.9 kW nominal output.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2093-AMP5
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2093-AMP5

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2093-AMP5
  • Product Family:
    Kinetix Servo Drive
  • Product Type:
    Kinetix 2000 Axis Module
  • Stock:
    1
  • Nominal DC Input:
    325 V DC
  • PWM Frequency:
    8 kHz
  • Efficiency:
    98%
  • Inverter Capacitance:
    200 µF
  • Energy Absorption:
    7.5 J
  • Power Rail Slots:
    One inverter slot
  • Continuous Output Current:
    3.0 A rms
  • Peak Output Current:
    9.0 A rms for 3 seconds from 0% utilization
  • Continuous Output Power:
    0.9 kW
  • Installed Dimensions:
    4.0 × 22.5 × 19.2 cm
  • Tariff Code:
    8504403090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Motor Network Thermal Application
  • Adds one Kinetix 2000 inverter channel to the shared Bulletin 2093 power rail
  • Draws its DC-bus and control-power connections from the integrated axis module
  • Exchanges motion commands through the installed SERCOS fiber-optic ring

2093-AMP5 serves as an axis module within a complete Kinetix 2000 multi-axis arrangement.

Correct selection depends on the IAM capacity, rail catalog number, occupied slots, regenerative duty, and supported motor-feedback hardware.

Before reuse or replacement, compare the nameplate Series, firmware, controller project, cabling, connectors, grounding, and thermal design.

Availability, condition, price, and shipping time for 2093-AMP5 are confirmed during quotation.

Allen-Bradley 2093-AMP5 Kinetix 2000 Axis Module Manuals, Datasheets, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • Motor compatibility is established through the official Kinetix combination tables
  • The motor-power cable is selected for the motor, brake, and module connection
  • Feedback type and feedback-cable catalog number must match the configured axis
  • SERCOS transmit and receive ports continue the drive-to-drive fiber ring
  • Node addressing is coordinated with the Logix motion configuration
  • Fiber connectors and cable routing are inspected before the axis is enabled
  • The module is mounted on the specified power rail inside a suitable enclosure
  • Published clearances are maintained for airflow and cable access
  • Total rail loading and regenerative duty are included in the enclosure thermal review
  • Additional servo axis for documented Kinetix 2000 multi-axis machinery
  • Replacement of an installed AMP5 after rail, motor, feedback, and firmware matching
  • SERCOS-controlled motion where the existing IAM and common power rail remain suitable
Description
2093-AMP5 is an Allen-Bradley Kinetix 2000 Axis Module for a single servo axis supplied through a compatible Bulletin 2093 power rail and Integrated Axis Module.

The module uses a nominal 325 V DC input and provides 3.0 A rms continuous current, 9.0 A rms peak current for up to 3 seconds from 0% utilization, and 0.9 kW continuous output.

Before installation, confirm the IAM and power-rail capacity, supported motor-feedback pair, SERCOS configuration, connector kit, 2090-series cables, load profile, firmware, enclosure thermal design, and grounding.
Alternative Names
2093-AMP5 2093AMP5 2093 AMP5 Allen-Bradley 2093-AMP5 Allen Bradley 2093-AMP5 AB 2093-AMP5 Rockwell Automation 2093-AMP5 Kinetix 2000 2093-AMP5
Technical notes
Check power-rail slots, IAM loading, SERCOS connectivity, motor-feedback compatibility, and the required cable hardware before replacement.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How do I confirm that Allen-Bradley 2093-AMP5 fits the existing power rail?
Verify the Bulletin 2093 power-rail catalog number, free inverter slot, installed IAM capacity, adjacent-module arrangement, and the required slot filler for every unused position.
Which installed information determines motor compatibility for Allen-Bradley 2093-AMP5?
Use the motor catalog number, winding, feedback device, brake option, motor-power cable, feedback cable, and the official Kinetix motor/drive combination tables.
What should be checked if Allen-Bradley 2093-AMP5 is not detected on SERCOS?
Check control power, node address, Logix project configuration, fiber transmit-to-receive routing, connector seating, cable condition, supported drive firmware, and ring continuity.
Can Allen-Bradley 2093-AMP5 be moved to another rail slot without changes?
Not automatically. Update and verify the physical slot arrangement, fiber-ring order, node addressing, motor and feedback cables, rail loading, and the controller project before operation.
What changes are expected when replacing Allen-Bradley 2093-AMP5 with 2198-C1007-ERS?
The engineering replacement uses the Kinetix 5300 platform. Revalidate mounting, AC power, EtherNet/IP motion, motor-feedback and cable compatibility, safe torque-off wiring, and Logix configuration.
Which manual covers the connectors for Allen-Bradley 2093-AMP5?
Rockwell Automation publication 2093-UM001 covers the Kinetix 2000 power rail, motor and feedback connectors, SERCOS fiber, grounding, wiring, and commissioning.
What details reduce delays when sourcing Allen-Bradley 2093-AMP5?
Provide a clear nameplate photo, complete catalog number and Series, quantity, condition, IAM and rail numbers, motor-feedback pair, controller and firmware, cable numbers, and destination.