Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power can help verify the exact installed variant before sourcing a replacement.

2711-K5A10

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2711-K5A10 is a PanelView 550 monochrome keypad terminal with DeviceNet communication and an RS-232 printer port for established machine operator-interface applications.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 2711-K5A10
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2711-K5A10

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2711-K5A10
  • Product Family:
    PanelView
  • Product Type:
    PanelView 550 Keypad Terminal
  • Stock:
    1
  • Product Type:
    PanelView 550 keypad terminal
  • Display:
    5.5-inch monochrome
  • Operator Input:
    Keypad
  • Primary Communication:
    DeviceNet
  • Auxiliary Port:
    RS-232 printer port
  • Power Supply:
    AC
  • Manufacturer:
    Allen-Bradley
  • Product Family:
    PanelView Standard 550
  • Catalog Number:
    2711-K5A10
  • Application Storage:
    Terminal-resident PanelView application
  • Lifecycle:
    Discontinued by OEM
  • Panel Mounting:
    Verify cutout before replacement
  • Migration Requirement:
    Application and network review required
  • Weight:
    1.2 kg
  • Estimated shipping dimensions:
    26.6 x 16.7 x 10.6 cm
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Operator Interface Communications Installation Product Applications

Features:

  • Terminal family: PanelView Standard 550 keypad HMI.
  • Display: 5.5-inch monochrome operator screen.
  • Communications: DeviceNet plus a separate RS-232 printer port.
The stored application supplies the machine screens, alarm text and command objects used by the operator.

DeviceNet node settings and the printer-port role are part of the installed terminal configuration.

Migration planning must include the application, panel opening, supply wiring and network conversion path.

Apter Power supports exact-catalog and migration review for the Allen-Bradley 2711-K5A10 PanelView 550 Terminal.
Allen-Bradley 2711-K5A10 PanelView 550 Terminal Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Uses a 5.5-inch monochrome display for application-defined graphics and text.
  • Accepts navigation and machine commands through the physical keypad.
  • Runs the alarm, status and control objects stored in the PanelBuilder32 project.
  • Uses DeviceNet as the primary controller network.
  • Provides a separate RS-232 port intended for printer connectivity.
  • Requires node address, baud rate and network wiring to be recorded before replacement.
  • Back up the approved terminal application before hardware removal.
  • Verify supply wiring, panel cutout and DeviceNet connector assignment.
  • Review any adapter plate, network gateway and converted project required by a newer HMI.
  • Operator interface on established DeviceNet-connected machinery.
  • Local display of production status, alarms and operating prompts.
  • Legacy HMI service where the original application and network configuration are retained.
Description
For machine stations that retain Allen-Bradley DeviceNet, 2711-K5A10 combines a 5.5-inch monochrome PanelView 550 display with a physical keypad. The loaded PanelBuilder32 application defines the screens, alarm messages and operator commands presented at the panel.

Its network identity is central to the catalog number: 2711-K5A10 uses DeviceNet for controller communication and includes a separate RS-232 printer port. This combination is not shared by PanelView 550 variants built for DH-485, Remote I/O or other networks.

A practical migration starts with the application file and network record because 2711-K5A10 is a discontinued platform. Preserve DeviceNet addressing, supply wiring and the panel opening before selecting replacement hardware or an adapter strategy.
Revisions

Revision Part #

Also known as

2711-K5A10 Ser A
2711-K5A10/A, Series A, Rev A
2711-K5A10 Ser B
2711-K5A10/B, Series B, Rev B
2711-K5A10 Ser C
2711-K5A10/C, Series C, Rev C
2711-K5A10 Ser D
2711-K5A10/D, Series D, Rev D
2711-K5A10 Ser E
2711-K5A10/E, Series E, Rev E
2711-K5A10 Ser F
2711-K5A10/F, Series F, Rev F
2711-K5A10 Ser G
2711-K5A10/G, Series G, Rev G
2711-K5A10 Ser H
2711-K5A10/H, Series H, Rev H
2711-K5A10X
2711-K5A10/X, Series X, Rev X
Alternative Names
Allen-Bradley 2711-K5A10 2711 K5A10 2711K5A10 2711-K5A1O 2711-KSA10 2711/K5A10 271I-K5A10 2711 K5A1O
Technical notes
Before servicing 2711-K5A10, back up the PanelView application and record DeviceNet node settings, baud rate, RS-232 usage and power wiring. Confirm the keypad terminal, monochrome display and panel cutout against the installed unit. A newer PanelView platform may require an adapter, wiring changes and application conversion rather than direct substitution.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
A DeviceNet node does not return after service; what should be checked first on 2711-K5A10?
Verify the terminal's node address and baud rate, then inspect DeviceNet network power, trunk or drop wiring, and termination. A lit display only confirms local power; it does not prove that the operator terminal has rejoined the network.
Can the RS-232 port on 2711-K5A10 replace its DeviceNet controller connection?
No. The controller data path for this catalog is DeviceNet, while the RS-232 port is assigned to its documented auxiliary function. Confirm the port role in the application records before attaching a cable or changing communications settings.
How should a stored PanelView application be transferred to 2711-K5A10 during maintenance?
Use the approved PanelBuilder32 workflow and a compatible ATA memory card or the documented transfer connection. Preserve the original project first, then confirm that the loaded application opens without conversion or validation errors.
The display is normal but several function keys trigger the wrong screens; is 2711-K5A10 necessarily defective?
Not necessarily. Compare the active application with the approved project and review each function-key assignment. If the project is correct, test the keypad systematically before concluding that the membrane or key electronics have failed.
Alarm times are incorrect after 2711-K5A10 was held in stores; what should maintenance inspect?
Set the real-time clock and check the condition of its backup source according to the service instructions. Confirm the timestamp again after a power cycle before relying on alarm history for troubleshooting.
A spare looks similar but its catalog suffix differs; can it be used in place of 2711-K5A10?
Do not decide by bezel appearance. Match the complete catalog number, DeviceNet communication role, supply type, keypad format, and the saved application requirements before accepting the spare for the machine.