Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
  • Lifecycle status

    Discontinued / Obsolete by OEM
    Apter Power reviews grayscale touch-terminal identity and installed communication needs.

2711P-T6M20A

/ 4.9
1001 reviews | Need a Specific Revision?
Allen-Bradley 2711P-T6M20A is a 5.5-inch grayscale touch terminal with EtherNet/IP, RS-232 and AC power for legacy PanelView Plus 600 systems.
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Get a quick price for 2711P-T6M20A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 2711P-T6M20A

  • Manufacturer:
    Allen-Bradley
  • Part Number:
    2711P-T6M20A
  • Product Family:
    Panelview Plus
  • Product Type:
    PanelView Plus 600 Touch Grayscale Terminal
  • Stock:
    1
  • Display:
    5.5-inch grayscale STN, 320 × 240
  • Operator Input:
    Touch screen
  • Communication:
    EtherNet/IP and RS-232
  • Input Power:
    AC
  • Flash Memory:
    64 MB
  • Weight:
    0.789 kg
  • Estimated shipping dimensions:
    15.2 x 18.5 x 9.8 cm
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Touch Operation Ethernet & Serial AC Installation Product Applications

Features:

  • 5.5-inch grayscale PanelView Plus 600 display.
  • Touch-screen operator input for on-screen navigation.
  • EtherNet/IP and RS-232 communication with AC input power.
The grayscale touch interface relies on the runtime to present every command, alarm and data-entry target.

Network and serial connections are both available, so the project and machine records must identify the path in use.

The AC-powered construction and grayscale display separate this terminal from D-suffix and color variants.

Apter Power supports document review, exact-model quotation and procurement for the Allen-Bradley 2711P-T6M20A PanelView Plus 600 Touch Grayscale Terminal.
Allen-Bradley 2711P-T6M20A PanelView Plus 600 Touch Grayscale Terminal Manuals and Support Links Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Touch objects provide navigation, entry and machine commands.
  • The grayscale screen reproduces the visual hierarchy designed in the runtime.
  • Calibration must support accurate selection of small or closely spaced targets.
  • Acceptance testing should cover alarms, entries and guarded commands.
  • EtherNet/IP carries the configured network controller route.
  • RS-232 supports the serial connection assigned by the project.
  • Addresses, shortcuts and serial settings must be recovered before removal.
  • Troubleshooting should begin with the communication path actually used by the runtime.
  • The A suffix denotes AC input power.
  • Protective earth and connector arrangement must match the original terminal.
  • Panel opening, mounting hardware and rear clearance must remain suitable.
  • Touch response and live controller data should be validated after power-up.
  • Grayscale touch HMIs in established PanelView Plus 600 systems.
  • AC-powered operator panels using EtherNet/IP.
  • Machines that retain an RS-232 controller or peripheral connection.
Description
Legacy machines that use a grayscale touch interface can run their operator screens on 2711P-T6M20A. Its touch-only bezel lets the application place navigation, alarms and data entry directly beside the process information they control.

The installed project may use EtherNet/IP or RS-232 through 2711P-T6M20A, and the terminal itself is supplied from AC power. Service work has to keep those two choices distinct: the communication path comes from the application, while the power suffix comes from the hardware catalog.

When 2711P-T6M20A is replaced, a clean project transfer is only the beginning. Touch calibration, controller addressing and the AC installation must all be validated before operators rely on the terminal for production decisions.
Revisions

Revision Part #

Also known as

2711P-T6M20A Ser A
2711P-T6M20A/A, Series A, Rev A
2711P-T6M20A Ser B
2711P-T6M20A/B, Series B, Rev B
2711P-T6M20A Ser C
2711P-T6M20A/C, Series C, Rev C
2711P-T6M20A Ser D
2711P-T6M20A/D, Series D, Rev D
2711P-T6M20AX
2711P-T6M20A/X, Series X, Rev X
Alternative Names
2711PT6M20A 2711P T6M20A 2711P-T6M2OA 27IIP-T6M20A Allen Bradley 2711P-T6M20A
Technical notes
2711P-T6M20A is an AC-powered grayscale touch PanelView Plus 600 with EtherNet/IP and RS-232. The T, M, 20 and A codes jointly define the operator method, display, communications and power. Avoid importing color-screen or Plus 6 specifications, and preserve the runtime before removal. Confirm touch calibration and alarm response after loading the project.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
Should a buyer accept a color terminal as a like-for-like replacement for 2711P-T6M20A?
Not without an application and operator review. This catalog is the grayscale touch version, so screen appearance and acceptance criteria may change on a color platform.
What must an electrician verify before energizing 2711P-T6M20A?
Verify the AC branch, protective earth and connector against the installed record; do not wire it as a D-suffix DC unit.
Where should a technician start when 2711P-T6M20A shows a communication alarm?
Use the saved project to identify the active path, then check the EtherNet/IP route or the RS-232 settings and cable for that path.
What should maintenance preserve before removing 2711P-T6M20A?
Preserve the runtime, communication shortcuts, terminal settings and calibration information so the replacement can recreate the installed station.
How should commissioning validate 2711P-T6M20A after a screen replacement?
Confirm touch calibration, navigation, data entry, alarms and guarded commands under the machine acceptance procedure.
What decisions belong in a migration plan for 2711P-T6M20A?
Decide how to convert the application, reproduce the touch workflow, retain controller links and adapt the panel and power arrangement before hardware is ordered.