Ask our team:
  • Phone: +86 181 0690 9650
  • E-Mail sales1@apterpower.com
How We Verify Your Order
Before dispatch, we confirm the exact model, revision, condition, inspection requirements and shipping documents for your order.
See a real on-site verification case >>
  • Lifecycle status

    Active / Available from OEM
    Apter Power supports quotation, documentation and configuration review for Bently Nevada 9200-03-02-10-00.

9200-03-02-10-00

/ 4.9
1001 reviews | Need a Specific Revision?
Bently Nevada 9200-03-02-10-00 is a two-wire Seismoprobe velocity transducer configured for 90-degree mounting, a side connector, an M10×1 circular base and no agency-approval option.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for 9200-03-02-10-00
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for 9200-03-02-10-00

  • Manufacturer:
    Bently Nevada
  • Part Number:
    9200-03-02-10-00
  • Product Family:
    9200 and 74712 Seismoprobe Velocity Transducers
  • Product Type:
    Seismoprobe Velocity Transducer
  • Stock:
    1
  • Mounting orientation:
    90° ±2.5°
  • Minimum operating frequency:
    4.5 Hz
  • Frequency response:
    4.5–1000 Hz, +0/−3 dB typical
  • Connector configuration:
    Side-mounted connector, no cable
  • Mounting base:
    Circular base with M10×1 stud
  • Sensitivity:
    20 mV/mm/s (500 mV/in/s) ±5%
  • Calibration load:
    10 kΩ
  • Coil resistance:
    1.25 kΩ ±5%
  • Coil inductance:
    125 mH typical
  • Maximum monitor lead:
    305 m
  • Operating temperature:
    −29 to +121 °C
  • Approval option:
    No agency approvals (code 00)
  • Weight:
    0.3 kg
  • Estimated shipping dimensions:
    7.83 x 5.4 x 4.14 cm
  • Tariff Code:
    Please confirm the destination before shipping
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Orientation & Response Signal & Wiring Mounting Applications

Features:

  • Passive sensing element: Two-wire moving-coil transducer with self-generated velocity-proportional output.
  • Physical configuration: 90-degree sensing orientation with a side-mounted connector and no attached cable.
  • Mounting interface: Circular base with an M10×1 stud for a defined machinery connection.
The sensor measures absolute vibration at a bearing housing, machine casing or structural point rather than shaft-relative motion.

A 10 kΩ receiving load and a documented lead-length boundary keep the transducer output tied to the intended 3300 or 3500 monitor input.

Its dust- and moisture-resistant construction supports industrial service when the connector and field wiring receive the documented environmental protection.

Apter Power supports technical documentation, quotation and configuration review for Bently Nevada 9200-03-02-10-00 Seismoprobe Velocity Transducer.
Bently Nevada 9200-03-02-10-00 Seismoprobe Velocity Transducer Manuals,Datasheets,Link
Important Notice: Confirm the sensing orientation, side-connector cable, M10×1 mounting surface, monitor input and required site approval before installation.
  • Angular calibration: Order option 03 sets the sensing orientation at 90° ±2.5°.
  • Low-frequency boundary: The selected orientation has a 4.5 Hz minimum operating frequency.
  • Usable response range: Typical response is 4.5–1000 Hz at +0/−3 dB.
  • Amplitude linearity: The transducer is rated ±5% from 0.254 to 127 mm/s at 100 Hz.
  • Output mechanism: Moving-coil construction generates a voltage proportional to vibration velocity without external power.
  • Nominal sensitivity: Proper orientation and termination provide 20 mV/mm/s (500 mV/in/s) ±5%.
  • Receiving condition: The OEM calibration load is 10 kΩ.
  • Polarity reference: Pin A is positive relative to pin B when case velocity moves toward the connector.
  • Connector arrangement: Option 02 places the connector on the side and supplies no integral cable.
  • Base configuration: Option 10 provides a circular mounting base with an M10×1 stud.
  • Mounting torque: The M10×1 base is tightened to 5.6 N·m (50 in-lb).
  • Operating temperature: The documented range is −29 to +121 °C.
  • Bearing-housing monitoring: The sensor measures absolute vibration velocity at a rigid bearing-housing location.
  • Machine-casing monitoring: The moving-coil output supports casing-vibration measurement on rotating equipment.
  • Structural measurement: A solid structural point can be monitored when it faithfully transmits the vibration of interest.
  • Monitoring modes: The OEM family supports both continuous monitoring and periodic measurement programs.
Description
Using moving-coil technology, 9200-03-02-10-00 converts absolute bearing-housing, machine-casing or structural vibration into a self-generated voltage proportional to velocity. Its passive two-wire design supports continuous monitoring and periodic measurements without an external excitation supply.

The 90-degree calibration of 9200-03-02-10-00 sets a 4.5 Hz lower operating limit, while the side-mounted connector leaves the signal cable as a separate installation choice. This combination helps engineers align the sensing axis and cable route with the machine housing before commissioning.

A circular M10×1 base gives 9200-03-02-10-00 a defined mechanical interface for a rigid measurement point. When installed on a housing that faithfully transmits machine vibration, the sensor can feed a 3300 or 3500 monitor over field wiring up to 305 m, subject to the documented frequency-roll-off limit.
Alternative Names
920003021000 9200 03 02 10 00 9200/03/02/10/00 9200_03_02_10_00 9200-03-02-10-0O 92OO-03-02-10-00 BN 9200 03 02 10 00 Bently Nevada 920003021000 9200 side mount M10x1 90 degree
Technical notes
Approval option 00 gives 9200-03-02-10-00 no CSA, ATEX or IECEx approval in this configuration. That boundary matters wherever the mounting location is classified, even when its 90-degree orientation and M10×1 base otherwise fit. For a hazardous-area project, choose an appropriately approved order code before installation.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
When is the 90-degree orientation of 9200-03-02-10-00 the correct response configuration?
It is the correct choice when the sensing axis and mounting surface call for the A03 orientation. That configuration is calibrated at 90° ±2.5° and has a 4.5–1000 Hz typical frequency range, so the measurement plan should use those response limits.
Does 9200-03-02-10-00 include an integral signal cable?
It does not include a cable. Connector option 02 is the side-mounted, no-cable version, allowing the field cable and route to be selected separately for the installed monitor and enclosure arrangement.
What mounting interface and tightening torque apply to 9200-03-02-10-00?
The selected base is circular with an M10×1 stud, and the OEM mounting torque is 5.6 N·m. A clean, rigid mounting surface helps the transducer follow housing motion without adding avoidable mechanical looseness.
What output and electrical load should the monitor provide for 9200-03-02-10-00?
The self-generating moving-coil output is 20 mV/mm/s (500 mV/in/s) ±5% when properly oriented and terminated. The calibration load is 10 kΩ, so the receiving channel should maintain the documented input condition.
How far can field wiring run from 9200-03-02-10-00 to a 3300 or 3500 monitor?
The documented maximum lead length is 305 m. Longer field runs introduce additional frequency roll-off, so the selected cable length should remain within that boundary and be evaluated against the required measurement bandwidth.
How can a technician confirm signal polarity on 9200-03-02-10-00?
Pin A becomes positive relative to pin B when case velocity is directed toward the connector. That OEM polarity convention gives a practical reference for wiring checks and channel-phase interpretation.
What vibration does 9200-03-02-10-00 measure on industrial machinery?
It measures absolute vibration velocity at bearing housings, machine casings and structural points. Choose a rigid location that represents the motion of interest rather than a flexible cover or bracket that could distort the reading.