Features:
- IC670GBI002 connects a Field Control I/O station to a Genius bus.
- One interface manages eight modules across four I/O terminal blocks.
- Each bus scan carries up to 128 input bytes and 128 output bytes.
The interface coordinates distributed field points and presents their cyclic data to a compatible Genius controller.
A two-modules-per-terminal-block layout keeps station expansion organized while allowing the electronics assembly to be removed separately.
Balanced input and output transfer areas support mixed Field Control stations without combining diagnostics with the normal I/O image.
The General Electric IC670GBI002 Field Control Genius Bus Interface Unit may still be available for purchase and support from Apter Power beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric IC670GBI002 Field Control Genius Bus Interface Unit Manuals,Datasheets,Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Network exchange and cable arrangement
- Cyclic Transfer: The station exchanges input and output images during every scheduled Genius scan.
- Datagram Service: Acyclic messages carry setup, command, and diagnostic information without displacing normal I/O data.
- Dual-Bus Option: Two Genius paths can be connected when the controller architecture provides a redundant network.
- Bus Commissioning: Node address, communication rate, cable polarity, and termination must agree across the segment.
Terminal blocks and module organization
- Block Capacity: Four Field Control terminal blocks attach to one bus interface assembly.
- Module Layout: Each terminal block accepts two I/O modules, producing an eight-module station limit.
- Stored Arrangement: Terminal-block memory retains the configured module sequence when interface electronics are exchanged.
- Rail Grounding: Conductive 35 mm DIN rail mounting establishes the mechanical base and grounding path.
Fault isolation and service behavior
- Host Reporting: Station and module conditions are returned through Genius diagnostics for controller-level analysis.
- Default States: Configured output defaults define field behavior when commanded data can no longer be refreshed.
- Module Checks: Seating, terminal power, wiring, and configured slot order narrow the cause of a reported I/O mismatch.
- Replacement Path: Retained terminal-block data reduces reconfiguration work after changing the interface unit.
Distributed I/O roles for Field Control
- Remote Machine I/O: Field points can be located near equipment while a Genius host performs central control.
- Process Islands: Mixed modules share one station for valves, sensors, and analog process signals.
- Serviceable Panels: Removable electronics allow the wiring base and station arrangement to remain installed during maintenance.
- Redundant Networks: Dual Genius paths suit systems designed to continue communication after one bus path is interrupted.