Open now · we reply within 2 working hours

Talk to our team

+86 15359408275

Call and you reach an account manager, not a queue.


What happens next?

  1. Email confirmationYou will get an email confirming that we have received your enquiry.
  2. Dedicated Account ManagerOne of our team will be in touch to confirm your part(s) specification and condition.
  3. Your quoteYou will receive a comprehensive quote tailored to your specific needs.

Supplied with every order

  • Commercial invoice and packing list
  • Nameplate and packaging photographs
  • 12-month Apter Power warranty
Need a specific document format for your import process? Say so in the enquiry and we will confirm before you order.

Recommended to use with 745-W2-P5-G5-HI-R-E-H

  • RE400REPJH1ABA RE400REPJH1A
  • URRHV Power Supply Module

All in stock · Add one and it is quoted together with the model, one shipping cost.

745-W2-P5-G5-HI-R-E-H

GE Multilin 745 two-winding transformer protection relay with 5 A CT inputs, restricted ground fault, enhanced display and conformal coating.

In Stock Ships by Wednesday, November 25 Fast Shipping Available
Dispatched within 24 hours of a confirmed order.
Nameplate and packaging photographs supplied before dispatch.
ISO 9001:2015 certified

Industry compliance and certified quality in every part we supply.

View certificate

Get a price for 745-W2-P5-G5-HI-R-E-H

745-W2-P5-G5-HI-R-E-HGeneral Electric Multilin 745 Two-Winding Transformer Protection Relay
Edit or add anything — monitor type, cable length, other part numbers.

Tell us which and we will shape the quote around it.

Attach a nameplate photo and an engineer will confirm the exact part number before quoting.

Answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8. Used only for this quotation.

Your Quote Request Has Been Received

Thank you. Our sales team will review your request and contact you shortly.

Ordering, delivery and after-sales

Your account managerNamed, start to finish

Your enquiry is picked up by a named account manager who checks the configuration before pricing and stays with the order through dispatch and after-sales. You are not passed round a shared inbox.

  • Direct email and WhatsApp for that person
  • Quotation signed by whoever prepared it
  • Same contact if anything needs sorting later

Enquiries are answered within 2 working hours, Mon–Fri 09:00–18:00 GMT+8.

Warranty12 months from shipment

Twelve months from date of shipment against functional defects under normal operating conditions. Because Apter Power is an independent supplier, the manufacturer’s own warranty does not apply — ours stands in its place, which on a discontinued part is the only cover there is.

If it arrives faulty or does not fitReturn authorisation same day

A written procedure, not a negotiation.

  • Report the fault within the 12-month warranty period
  • We issue a return authorisation the same working day
  • Return the unit within 14 days of reporting, in antistatic packaging where applicable
  • Replacement, repair or refund at our option, confirmed in writing
  • Return shipping on a confirmed warranty defect is at our cost

If it turns out to be a configuration mismatch rather than a fault, we help you identify the correct part instead of leaving you with the wrong one.

Pre-dispatch inspectionWhat we check — and what we don’t

Checked:

  • Part number and revision read from the unit nameplate, and photographed
  • Outer packaging and seals inspected and photographed
  • Connector threads and mounting stud checked for damage
  • Quantity and accessory contents verified against the packing list

Not checked: no powered functional or calibration test is performed on this item; sensitivity and frequency response are not re-certified by Apter Power; no hazardous-area certification is issued by us. If you need a functional test report before shipment, ask when you request the quote and we will confirm whether it is possible and what it adds to the lead time.

Our quality management is certified to ISO 9001:2015. More usefully, the scope above is published rather than summarised as “tested and approved” — nothing is implied that we did not do.

Shipping, customs and documentsDispatch in 24h · 170+ countries

Dispatch within 24 hours of a confirmed order for items held in stock. DHL, FedEx and UPS express to 170+ countries, typically 3–6 working days door to door; tracking is emailed the day the order leaves us. Shipping method and cost are itemised on every quotation and never added afterwards.

Most delays on an international spare are paperwork rather than freight, so the documents are prepared before the parcel leaves:

  • Commercial invoice and packing list on every shipment
  • Certificate of Origin prepared on request — ask at enquiry stage
  • HS code stated on the quotation, not discovered at clearance
  • We work to your broker’s format if you tell us what it is
PaymentTelegraphic transfer only

We accept payment by telegraphic transfer (T/T) only. Bank details appear on the pro-forma invoice and nowhere else — we never send revised bank details by email after quoting. If you receive a message claiming our account has changed, call +86 15359408275 before paying.

How to orderSend the part number

Send the enquiry above, or email the part number, quantity and destination country. In-stock items show a live quantity; where a part is not held we show "Ask" and confirm availability from our supplier network before quoting, so you are never quoted a lead time we cannot meet.

Discover the experience, people and global sourcing expertise behind Apter Power. About us »

Technical specifications

 set by the part-number suffix dotted  awaiting confirmation against the OEM datasheet

Part identification

Manufacturer
General Electric
Part Number
745-W2-P5-G5-HI-R-E-H
Product Family
GE Multilin
Product Type
Multilin 745 Two-Winding Transformer Protection Relay
Stock
1
Weight
8.33 kg
Estimated shipping dimensions
22.4x21.6x25.2cm
Tariff Code
Please confirm the destination before shipping
Country of origin
USA
Place of shipment
Xiamen,Fujian,China

More information

Features:

  • Two-winding differential and restricted ground-fault protection for 5 A CT circuits.
  • Enhanced display supports local review of metering, alarms, events and settings.
  • Harsh-environment conformal coating improves resistance to corrosive contaminants.
The relay remains subject to the published temperature, humidity and enclosure limits even with the coating option.

The fully drawout case provides automatic CT shorting for controlled maintenance withdrawal.

Event records, oscillography and programmable logic support analysis of transformer protection operations.

For General Electric 745-W2-P5-G5-HI-R-E-H Multilin 745 Two-Winding Transformer Protection Relay support, Apter Power provides quotations, technical documents and configuration review.
General Electric 745-W2-P5-G5-HI-R-E-H Multilin 745 Two-Winding Transformer Protection Relay Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
  • Use the conformal-coated assembly where corrosive airborne contaminants are an identified panel risk.
  • Maintain operation within -20°C to +60°C and non-condensing humidity limits.
  • Control condensation, dust accumulation and conductive deposits through enclosure design and maintenance.
  • Inspect terminals, coating condition and ventilation paths during planned protection-panel outages.
  • Verify both winding CT circuits and the neutral CT before landing conductors on the rear terminals.
  • Confirm station power is inside the high-range AC or DC supply window.
  • Use the enhanced display to check live metering only after polarity and ratio tests are complete.
  • Follow the approved drawout procedure and verify automatic CT shorting during maintenance tests.
  • Test percentage-differential restraint and inrush blocking with documented secondary-injection cases.
  • Prove restricted ground-fault stability for external faults and sensitivity within the winding zone.
  • Use the enhanced display to review self-test alarms, current balance and event chronology at the panel.
  • Correlate oscillography with breaker and transformer records before resetting an unexplained trip.
  • Two-winding utility or industrial transformers with 5 A secondary CT circuits.
  • Panels exposed to corrosive chemical contaminants where conformal coating is specified.
  • Sites that depend on clear local display access for commissioning and maintenance work.
  • Transformer zones requiring sensitive restricted ground-fault protection and event investigation.

Description

Harsh-environment service is a key identifier for 745-W2-P5-G5-HI-R-E-H: its conformal-coating option helps protect electronics from corrosive contaminants while normal temperature, humidity, enclosure and panel-cleanliness limits still apply.

For two-winding transformer protection, 745-W2-P5-G5-HI-R-E-H accepts 5 A phase and ground CT inputs and combines differential protection with restricted ground-fault coverage. The enhanced display gives local access to metering, alarms, events and settings.

The fully drawout case used by 745-W2-P5-G5-HI-R-E-H automatically shorts CT circuits when the relay is withdrawn. This construction supports maintenance access, but the CT secondary ratings, station supply and protection settings must still match the installed transformer scheme.

Case studies

Order from our published case studies. Each one names the customer situation, the parts involved and what changed.

Myrtle
Saudi ArabiaGE Fanuc IC693CPU364

Saudi Buyer Verifies GE IC693CPU364 On-Site

An Saudi project buyer with a China-based office visited three suppliers with an engineer after a previous purchase resulted in poor-quality goods that were not regarded as original. Following an on-site review of GE Fanuc IC693CPU364, IC693CPU372, IC693ALG391 and other stock in Xiamen, the customer selected IC693CPU364, placed an order and planned to test the module first.

3GE models reviewed
Trial OrderTest before wider purchase
“ Seeing the actual GE modules and stock in person gave us confidence to place our first test order. — Hassan ”
Myrtle · Saudi Arabia · October 2026
Read the full case study
May
UAEGE IS200VVIBH1C

Evidence Before Delivery

A Dubai power-project customer visited Apter Power in Xiamen to inspect GE turbine-control cards, labels, packaging and visible condition before delivery.

On siteCustomer inspection in Xiamen
Pre-deliveryIdentity & condition reviewed
“ Seeing the products, labels and inspection process in person gave us a clearer understanding of Apter Power's quality control. — Muhammad ”
May · UAE · October 2026
Read the full case study
May
Malaysia3500/22M

Malaysia Customer Collects Bently Nevada 3500/22-01-02-00 After On-Site Inspection

After equipment downtime, a Malaysian customer travelled to Xiamen to inspect and collect a Bently Nevada 3500/22-01-02-00. The unit could be tested and put into use the next day, helping shorten factory downtime and reduce associated losses.

5On-site checks
1 dayReady for testing
“ Apter responded quickly and had the right Bently Nevada module ready for us to inspect and collect. — Shah ”
May · Malaysia · October 2026
Read the full case study

Where this item is used

The nine industries we publish solutions for. Each links through to that industry page.

FAQs

Questions we actually get about this item. If yours is not here, put it in the message field above.

About this part

When does the H option of 745-W2-P5-G5-HI-R-E-H add practical value?

It is useful where the protection panel may be exposed to corrosive chemical contaminants. It does not make the relay weatherproof, so the enclosure, condensation control, cleanliness and published environmental limits still govern installation.

How can the enhanced display of 745-W2-P5-G5-HI-R-E-H help during commissioning?

Use it to compare live phase and ground currents, review active alarms and confirm selected settings after wiring tests. It supports field checks, but the approved settings file remains the controlled configuration record.

What should be checked if restricted ground-fault operation in 745-W2-P5-G5-HI-R-E-H is unexpected?

Review neutral and phase CT polarity, ratios, grounding path and the intended protection-zone boundary. Then test stability for through current and sensitivity for current injected inside the zone.

How should 5 A CT circuits be verified before placing 745-W2-P5-G5-HI-R-E-H in service?

Confirm each phase and neutral CT ratio, polarity, terminal number and grounding point against the transformer drawings. Compare live current balance and complete secondary-injection tests before enabling trips.

What is the safest way to stage a spare 745-W2-P5-G5-HI-R-E-H for a planned outage?

Record the installed order code, firmware, settings file, terminal schedule and trip logic before the outage. Bench-check the spare and prepare a controlled test plan so work is not dependent on front-panel copying alone.

Does the E option give 745-W2-P5-G5-HI-R-E-H an Ethernet port?

No. The E option identifies the enhanced display. Network interfaces depend on the communication options actually fitted to the relay, so inspect the rear ports and project documentation before planning SCADA work.

Can't find the part number you need?

We quote thousands of parts that never appear on this site — current, obsolete and hard to find. Send the number and we will tell you honestly whether we can get it.

Mon–Fri 09:00–18:00 GMT+8 · enquiries answered within 2 working hours

Talk to our team

An account manager works the enquiry through with you — checking the configuration before pricing, rather than sending a price list back.

Mon–Fri 09:00–18:00 GMT+8 · Xiamen, China

ISO 9001:2015 certified

Every part we supply meets industry standards and comes from a certified quality management system.

View certificate

You may also like

RE400REPJH1ABA
RE400REPJH1ABA is a high-reliability industrial control module designed by GE (General Electric) for its Mark VIe control system. It is mainly used for signal processing and system interface applications in the control system.
UR7KH
The GE UR7KH high-speed communication module is designed to facilitate secure point-to-point data exchange in power system protection networks and is specifically designed to address long-distance guided auxiliary protection schemes.
URRHV
The GE URRHV is a vertical-mount power supply module for the Multilin Universal Relay series, converting 100-240V AC or 125-250V DC into regulated DC power for relay operation.
In stock
UR6UH
GE Vernova UR6UH is a Multilin Universal Relay 6U module combining six non-monitored Form-A outputs with four digital contact inputs. It supports compact breaker control, annunciation and interlocking schemes.
In stock
UR6TH
GE UR6TH is a 6T digital I/O module for the Multilin Universal Relay platform. It combines eight digital inputs with four Form-A outputs that do not include output-current monitoring.
In stock
269PLUS-100P-120
GE 269PLUS-100P-120 is a 269 Plus digital motor management relay configured for 100 Ω platinum RTDs and 120 V AC / 125 V DC control power.
In stock
745-W2-P5-G5-HI-R-E-H
GE Multilin 745 two-winding transformer protection relay with 5 A CT inputs, restricted ground fault, enhanced display and conformal coating.
In stock
745-W3-P511-G51-HI-R-E
GE Multilin 745 three-winding transformer protection relay with 5/1/1 A phase CTs, 5/1 A ground CTs, restricted ground fault and enhanced display.
In stock
750-P5-G5-HI-A20-R
GE Multilin 750 feeder management relay with 5 A phase and ground inputs, high-range control power and 4–20 mA analog outputs.
In stock
750-P5-G5-D5-HI-A1-R
750-P5-G5-D5-HI-A1-R is a GE Multilin SR750 feeder management relay configured for 5 A phase, ground and polarizing current inputs.
In stock

Looking for a part-number suffix that is not listed? We quote thousands of Bently Nevada configurations that never appear on the site — send the part number.

Same kind of part from other manufacturers:

Product browsing history

Request a quote WhatsApp Chat