GE NP104X905BA603 is an operator-control keypad assembly associated with legacy Mark V turbine interfaces and must be matched by its complete BA603 hardware execution.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for NP104X905BA603
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for NP104X905BA603

  • Manufacturer:
    General Electric
  • Part Number:
    NP104X905BA603
  • Product Family:
    SPEEDTRONIC Mark V
  • Product Type:
    Mark V Operator Control Keypad
  • Stock:
    1
  • Associated Platform:
    GE Mark V operator interface
  • Assembly Code:
    NP104X905
  • Execution Suffix:
    BA603
  • User Interface:
    Dedicated labeled key matrix
  • Replacement Basis:
    Complete label, overlay, connector and host panel
  • Tariff Code:
    8537109090
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Operator Entry Host Interface Keypad Migration Application
  • Provides local operator key entry for the associated Mark V interface
  • BA603 suffix remains part of the complete keypad hardware identity
  • Connector, key legend and host-interface assignment must match the installed unit

NP104X905BA603 is a legacy GE operator keypad used with a Mark V operator-interface arrangement rather than a turbine protection or I/O processor board.

Its purchasing risk lies in the physical execution: key legends, overlay, connector location, mounting cutout and host electronics can differ even when an assembly is described generically as NP104X905.

Public manufacturer material for the complete BA603 execution was not located, so communication protocol, supply voltage and environmental ratings are left unpublished until an exact drawing or label is available.

Availability, condition, price, and shipping time for NP104X905BA603 are confirmed during quotation.

General Electric NP104X905BA603 Mark V Operator Control Keypad Product Family, Support, Links

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

  • The labeled key matrix sends discrete operator selections
  • Command meaning is defined by the host interface
  • Maintenance testing prevents unintended live process actions
  • The rear connector and cable bind the keypad to its panel electronics
  • The host display provides the response to each key selection
  • Cable and connector identity are captured before removal
  • The BA603 suffix is retained as the execution reference
  • Overlay legends are compared key by key
  • Cutout, studs and connector clearance are measured from the installed panel
  • Mark V turbine operator command entry
  • Legacy operator-interface keypad replacement
  • Panel-based navigation and acknowledgment functions
Description
NP104X905BA603 is a GE keypad panel for operator command entry in a legacy turbine-control interface.

The assembly should be treated as a complete human-machine hardware component, including its overlay, switch matrix, connector and mounting frame, not as a generic keyboard replacement.

Before purchase, provide front and rear photographs, connector pin count, cable label, cutout dimensions and host-panel identity; after installation test every key, command interlock and display response without issuing unsafe process actions.
Alternative Names
NP 104X905BA603 NP-104X905BA603 NP104X905 BA603 GE NP104X905BA603 GE Fanuc NP104X905BA603 Mark V Keypad NP104X905BA603
Technical notes
NP104X905BA603 must match the complete BA603 label, key legend, switch matrix, rear connector, mounting cutout, host-panel cable and command mapping; a visually similar keypad may issue incorrect operator actions.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
What photographs are required to identify NP104X905BA603 correctly?
Provide the complete front overlay, rear label, connector, mounting studs, cable markings and host-panel nameplate in clear focus.
Can NP104X905BA603 be replaced by another NP104X905 keypad?
Only after the BA603 suffix, key legend, switch matrix, connector and mounting dimensions are proven identical.
How should NP104X905BA603 key operation be tested safely?
Use the approved maintenance or simulation mode and verify each key response without enabling starts, trips, load changes or other live process commands.
What causes intermittent keys on NP104X905BA603 after installation?
Misaligned mounting, a partially seated ribbon connector, contamination, overlay damage or a mismatched switch matrix can cause intermittent operation.
Does NP104X905BA603 store the Mark V control program?
The keypad is an operator-entry device; do not treat it as the controller or project-storage module without specific host documentation.
Which mechanical measurements matter for NP104X905BA603?
Measure the panel cutout, stud pattern, overall bezel, connector clearance and cable bend radius from the installed unit before ordering.
What acceptance record should be kept for NP104X905BA603?
Record every key test, displayed response, cable seating, overlay condition and any command inhibited during maintenance.