HIMA F7105A is a six-channel fused current distribution module that feeds protected 24 V DC paths to module subframes and reports a blown fuse through LEDs and a relay contact.
In Stock
Ships by Saturday, November 14
Fast Shipping Available
Get a quick price for F7105A
Quantity
*E-mail
Company
*Mobile
*Content
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)

Technical specifications for F7105A

  • Manufacturer:
    HIMA
  • Part Number:
    F7105A
  • Product Family:
    HIMA Power Supplies & Accessories
  • Product Type:
    6-Channel Fused Current Distribution Module
  • Stock:
    1
  • Fused current paths:
    6
  • Operating voltage:
    24 V DC, -15% to +20%
  • Module current consumption:
    65 mA
  • Permitted ripple:
    Less than 15%
  • Delivered fuse rating:
    Maximum 4 A time-delay per path
  • Current-path terminals:
    d6, d8, d10, d12, d14, and d16
  • Parallel supply terminals:
    z2 and z4
  • Status indication:
    Six channel LEDs plus ERR LED
  • Aggregate status contact:
    Floating changeover contact at d28-d30
  • Fault response:
    Affected channel LED and ERR LED flash; status contact opens
  • Unused-path behavior:
    LED off; unused path not monitored
  • Relay switching voltage:
    Up to 30 V AC or DC
  • Relay switching current:
    Up to 4 A
  • Approximate relay switching time:
    60 ms
  • Ambient range:
    -25 to +70 °C
  • Space requirement:
    4 TE
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen,Fujian,China
By purchasing this item, you agree to the Terms & Conditions, ApterPower is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All our products come with ApterPower's 1-year warranty.

More Information

Overview Manuals Path Distribution Fault Indication Relay Interface Supply Limits

Features:

  • Distributes one 24 V DC source through six separately fused current paths.
  • Indicates every active path with its own LED and reports a fuse fault with a flashing ERR indicator.
  • Provides a floating d28-d30 changeover contact for the combined monitored-fuse condition.
HIMA F7105A organizes six protected outgoing feeds without combining their fuse status into one invisible wiring branch.

The front indication shows which path is affected, while the relay contact carries one cabinet-level condition for the monitored paths.

Parallel supply terminals z2 and z4 are part of the input arrangement; each outgoing path still retains its own fuse.

The HIMA F7105A 6-Channel Fused Current Distribution Module is listed as Discontinued / Obsolete by OEM; Apter Power can assist with exact-model documentation and matching.
HIMA F7105A 6-Channel Fused Current Distribution Module Manuals,Datasheets,Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Six separately protected feeds

  • Incoming paths: Terminals d6 through d16 accept the six path supplies.
  • Fuse boundary: Every outgoing path has its own time-delay fuse.
  • Load destination: The protected paths feed the connected module subframes.
  • Parallel input: Terminals z2 and z4 allow parallel 24 V DC supply connection.

Channel and aggregate fault reporting

  • Normal path: The related front LED is illuminated while its monitored fuse is intact.
  • Blown fuse: The affected channel LED and the ERR LED flash.
  • Relay action: A monitored fuse fault opens the d28-d30 contact.
  • Unused path: An unconnected path is not included in the aggregate fault condition.

Visual status and external contact

  • Contact form: The output is a floating changeover contact.
  • Connection: The aggregate output is assigned to d28-d30.
  • Voltage limit: The relay path is rated up to 30 V AC or DC.
  • Current limit: The switching-current ceiling is 4 A.

Electrical and environmental boundaries

  • Nominal source: The module operates from 24 V DC.
  • Tolerance: The accepted source range is -15% to +20%.
  • Electronics load: Internal module consumption is 65 mA.
  • Ambient: The documented operating boundary is -25 to +70 °C.
Description
HIMA F7105A is a six-channel current distribution module for protected 24 V DC feeds in the Planar F hardware system. Its six fused paths provide line protection while distributing operating power to connected module subframes.

Supply enters F7105A through terminals d6, d8, d10, d12, d14, and d16, while z2 and z4 allow parallel connection of 24 V DC operating sources. This arrangement keeps each outgoing path separately fused even when the incoming supply is paralleled.

A dedicated front LED follows every current path on F7105A. When an installed fuse opens, its channel LED and the ERR LED flash and the floating d28-d30 changeover contact opens; an unused path remains unmonitored and does not open the contact.

Each delivered path in F7105A uses a maximum 4 A time-delay fuse, while the module electronics draw 65 mA from the 24 V DC supply. The relay interface is rated up to 30 V AC or DC and separates the aggregate fuse condition from the six individual visual indications.
Alternative Names
F 7105A F-7105A F7105 A HIMA F7105A HIMA F 7105A F7105A Current Distributor F7I05A F710SA
Technical notes
HIMA F7105A is the six-fold current-distribution assembly identified as drawing 9718; its six incoming path terminals and d28-d30 status contact must be wired as separate functions.
Exceptional Service

Our Mission

  • 100% Satisfaction

    We believe expertise is priceless. With over 20 years of experience, and top engineers on staff, we can help you solve or avoid problems that threaten your business.
  • Trust Guaranteed

    Not only do we have a vast inventory, our team makes sure every piece of equipment is in working condition. Your purchases are also backed by our Warranty.
  • Expertise

    Time is money, especially when your equipment is down. We work quickly to get your equipment on its way so you can get it back up and running.

FAQS

The following is a list of questions commonly asked by our customers. Please contact us if you have a question about our process that is not answered below.
How are the six outputs protected on HIMA F7105A?
HIMA F7105A assigns a separate maximum 4 A time-delay fuse to each of its six current paths, so one branch fault does not remove the other path fuses.
Which terminals receive the path supplies on HIMA F7105A?
The six path supplies on HIMA F7105A enter at d6, d8, d10, d12, d14, and d16, with z2 and z4 available for parallel 24 V DC feeding.
What does HIMA F7105A show when one monitored fuse opens?
When a fuse opens, HIMA F7105A flashes the associated channel LED together with the ERR LED and opens the d28-d30 aggregate status contact.
Does an unused channel create a fault on HIMA F7105A?
No. An unconnected path on HIMA F7105A leaves its channel LED off, but the aggregate contact remains closed because that unused path is not monitored.
How is cabinet-level fuse status exported by HIMA F7105A?
A floating changeover contact at d28-d30 lets HIMA F7105A transfer the combined state of all monitored fuses to an external indication or control circuit.
Which supply tolerance applies to HIMA F7105A?
For HIMA F7105A, the 24 V DC operating source may vary from -15% to +20%, with ripple kept below the documented 15% limit.